Polarity wave area ratio method of ±800 kV UHVDC transmission line fault line selection

被引:0
|
作者
Shu, Hong-Chun [1 ]
Zhu, Sheng-Qiang [2 ]
Tian, Xin-Cui [1 ]
Yang, Yi [1 ]
机构
[1] Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650051, China
[2] Anning Bureau, Extra High Voltage Transmission Company, China Southern Power Grid Co., Ltd., Kunming 650000, China
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
21
引用
收藏
页码:888 / 896
相关论文
共 50 条
  • [1] Fault location based on wavelet energy spectrum and neural network for ±800 kV UHVDC transmission line
    Liu, Kezhen
    Shu, Hongchun
    Yu, Jilai
    Tian, Xincui
    Luo, Xiao
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2014, 34 (04): : 141 - 147
  • [2] Conductor schemes for ±800 kV UHVDC transmission line of nuozhadu-guangdong
    Xue, Zhi-Fang
    Cheng, Si-Yong
    He, Min
    Zhong, Qian
    Huang, Wen-Jing
    Lu, Ben-Chu
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (10): : 2344 - 2349
  • [3] Corona Onset Characteristics of Grading Rings on ±800kV UHVDC Transmission Line
    Dai, Mengting
    Yu, Zhanqing
    Gao, Zhiye
    Li, Shi
    Zeng, Rong
    Zhang, Bo
    Li, Min
    Li, Ruihai
    Liu, Lei
    Gao, Chao
    2014 INTERNATIONAL CONFERENCE ON INFORMATION SCIENCE, ELECTRONICS AND ELECTRICAL ENGINEERING (ISEEE), VOLS 1-3, 2014, : 804 - +
  • [5] Altitude Correction Method for Audible Noise of ± 800 kV UHVdc Overhead Transmission Line and its Engineering Application
    Zhao, Luxing
    Xie, Li
    Wang, Dafei
    He, Kun
    Gao, Lei
    Ju, Yong
    Lu, Jiayu
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (05) : 3375 - 3386
  • [6] Fault analysis of ±800 kV UHVDC transmission converter valve and optimal design method
    Wang H.
    Lin Z.
    Zhang H.
    Zheng L.
    Yang S.
    Song L.
    Wang, Huafeng (wanghuafeng@geiri.sgcc.com.cn), 2017, Science Press (43): : 67 - 73
  • [7] The study on the radio interference from ±800kV Yun Guang UHVDC transmission line
    Wan Baoquan
    Liu Dichen
    Wu Xiong
    Lu Yao
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 130 - +
  • [8] Lightning withstand performance of the Yun-guang ±800 kV UHVDC power transmission line
    Shang, Tao
    Du, Zhong-Dong
    Zhang, Cheng-Wei
    Liu, Xi
    Gaodianya Jishu/High Voltage Engineering, 2008, 34 (10): : 2086 - 2089
  • [9] ±800 kV UHVDC transmission line protection based on single end electrical transient signal
    Shu, Hongchun
    Liu, Kezhen
    Zhu, Shengqiang
    Zhang, Guangbin
    Zhu, Zizhao
    Zhang, Min
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (31): : 108 - 117
  • [10] Influence of 800 kV UHVDC in earth on buried steel line pipes
    Zhang L.
    He M.
    Zhang L.
    Natural Gas Industry, 2019, 39 (12): : 134 - 138