Contact erosion characteristics in making process of SF6 circuit breakers

被引:0
|
作者
机构
[1] Ding, Can
[2] Yuan, Xichao
[3] Li, Zhibing
[4] Yuan, Zhao
[5] Pan, Yuan
[6] He, Junjia
来源
Ding, Can | 1600年 / Science Press卷 / 40期
关键词
Copper alloys - Electric circuit breakers - Electric network analysis - SF6 insulation - Timing circuits - Binary alloys - Friction - Tribology - Sulfur hexafluoride - Wear of materials;
D O I
10.13336/j.1003-6520.hve.2014.10.040
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] A Comparison of Contact Erosion for Two Types Arcing Contact of SF6 Circuit Breakers in Making Process
    Ding, Can
    He, Junjia
    Yuan, Xichao
    Yuan, Zhao
    Pan, Yuan
    PROCEEDINGS OF 2014 SIXTIETH IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS (HOLM), 2014, : 170 - 176
  • [2] Influence of Contact Erosion on the State of SF6 Gas in Interrupter Chambers of HV SF6 Circuit Breakers
    Kim, Myoung-Hoo
    Kim, Kyong-Hoe
    Smajkic, Amer
    Kapetanovic, Mirsad
    Muratovic, Mahir
    2014 IEEE INTERNATIONAL POWER MODULATOR AND HIGH VOLTAGE CONFERENCE (IPMHVC), 2014, : 466 - 469
  • [3] Erosion of Cu-W contact material of SF6 circuit breakers when making capacitor bank
    Ding, Can
    Li, Chengxi
    Fang, Chunhua
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2020, 15 (02) : 187 - 193
  • [4] Evaluation method of contact erosion for high voltage SF6 circuit breakers using dynamic contact resistance measurement
    Cheng, Tingting
    Gao, Wensheng
    Liu, Weidong
    Li, Ruipeng
    ELECTRIC POWER SYSTEMS RESEARCH, 2018, 163 : 725 - 732
  • [5] Prestrike modeling in SF6 circuit breakers
    Homaee, Omid
    Gholami, Ahmad
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 114 (114)
  • [6] The contact erosion characteristics of SF6 circuit breaker based on dynamic resistance measurement method
    Chen, Gong
    Li, Mengbo
    Wang, Qi
    Lu, Xiaojun
    Zhang, Sixiang
    Luo, Daijun
    ENERGY REPORTS, 2022, 8 : 1081 - 1089
  • [7] Erosion characteristics of SF6 circuit breaker contacts based on dynamic contact resistance measurement
    Lan L.
    Chen G.
    Wen X.
    Wu Y.
    Chen, Gong (gongchen714@163.com), 1731, Science Press (42): : 1731 - 1738
  • [8] ARC MODELING IN SF6 CIRCUIT-BREAKERS
    VERITE, JC
    BOUCHER, T
    COMTE, A
    DELALONDRE, C
    ROBINJOUAN, P
    SERRES, E
    TEXIER, V
    BARRAULT, M
    CHEVRIER, P
    FIEVET, C
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1995, 142 (03) : 189 - 196
  • [9] The testing of SF6 generator circuit-breakers
    Smeets, RPP
    van der Linden, WA
    IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (04) : 1188 - 1193
  • [10] PRACTICAL PROBLEMS ON SF6 GAS CIRCUIT BREAKERS
    USHIO, T
    SHIMURA, I
    TOMINAGA, S
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1971, PA90 (05): : 2166 - &