An inexpensive weight bearing indicator used for rehabilitation of patients with lower extremity injuries

被引:0
|
作者
Department of Mechanical, Aerospace and Nuclear Engineering, Rensselaer Polytechnic Institute, 110 8th Street, Troy, NY 12180-3590, United States [1 ]
机构
来源
J. Med. Devices Trans. ASME | 2007年 / 1卷 / 38-46期
关键词
Biomedical engineering - Buckling - Human rehabilitation equipment - Musculoskeletal system;
D O I
10.1115/1.2355690
中图分类号
学科分类号
摘要
Background. Partial or nonweight bearing is a useful treatment prescribed by medical professionals (e.g., orthopedists, podiatrists) for patients rehabilitating from lower extremity injuries However, there is significant variability in patient conformance with the commonly used, but very imprecise weight scale method. Furthermore, the few commercially available load monitoring devices are rarely used because of their high cost. Method of Approach. As a simple and inexpensive alternative to current load monitoring methods and commercial products, a new medical device called a snap dome weight bearing indicator (WBI) has been developed to gently warn a patient when they have exceeded a limited percentage of their body weight on the recovering leg or foot. When installed in a patient's shoe or medical appliance, the device does so by utilizing the reversible buckling phenomena of a snap dome to provide a tactile and audible feedback when the prescribed weight has been exceeded. To demonstrate the feasibility of this new device, the performance of (1) the snap dome by itself and (2) several WBI designs developed were tested. The most useful of the new designs include one incorporating a heel cup for loose fitting medical appliances and a podiatric off-loading indicator (POLI). In addition, a pilot study and manufacturing cost analysis of the POLI device were performed to investigate patient usability and affordability issues. Results. The particular four-leg snap domes used in device prototypes performed quite well with regards to buckling load consistency between domes, the linearity of buckling load by stacking domes in a parallel arrangement, and buckling load repeatability of a single dome. The performance of each WBI prototype was tested with regards to load transfer, tactile, and audible feedback to the patient, patient comfort, and ease of installation. Prototype performance was generally very good or excellent except for the POLI device, which does not provide sufficient tactile or audible feedback for many patients. A costing analysis of the POLI device suggests that it can be manufactured in the U.S. for around one dollar. Conclusions. The generally positive results from performance testing of commercially available snap domes and WBI prototypes suggest that this new medical device will indeed be an inexpensive, yet effective conformance tool for orthopedists and podiatrists to use in prescribing partial or no weight bearing for a patient. Copyright © 2007 by ASME.
引用
收藏
相关论文
共 50 条
  • [1] An Inexpensive Weight Bearing Indicator With Load Range Capability for Rehabilitation of Patients With Lower Extremity Injuries
    Walczyk, Daniel F.
    Ziomek, William T.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2009, 3 (03):
  • [2] Analysis of partial weight bearing after surgical treatment in patients with injuries of the lower extremity
    Alexander Maximilian Eickhoff
    Raffael Cintean
    Carina Fiedler
    Florian Gebhard
    Konrad Schütze
    Peter H. Richter
    Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 77 - 81
  • [3] Analysis of partial weight bearing after surgical treatment in patients with injuries of the lower extremity
    Eickhoff, Alexander Maximilian
    Cintean, Raffael
    Fiedler, Carina
    Gebhard, Florian
    Schuetze, Konrad
    Richter, Peter H.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (01) : 77 - 81
  • [4] The weight of obesity in patients with lower extremity vascular injuries
    Simmons, Jon D.
    Duchesne, Juan C.
    Ahmed, Naveed
    Schmieg, Robert E., Jr.
    Rushton, Fred W.
    Porter, John M.
    Mitchell, Marc E.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (05): : 582 - 584
  • [5] Is It Possible to Train Patients to Limit Weight Bearing on a Lower Extremity?
    Hustedt, Joshua W.
    Blizzard, Daniel J.
    Baumgaertner, Michael R.
    Leslie, Michael P.
    Grauer, Jonathan N.
    ORTHOPEDICS, 2012, 35 (01) : E31 - E37
  • [6] Load Monitoring System for Partial Weight Bearing Therapy for Rehabilitation of Lower Extremity Fractures
    North, Kylee
    Kubiak, Erik N.
    Hitchcock, Robert W.
    Petelenz, Tomasz J.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 152 - 155
  • [7] WEIGHT-BEARING PROSTHESIS FOR LOWER EXTREMITY
    HICKEY, CH
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1961, 43 (03): : 462 - 462
  • [8] The effects of an early intrahospital rehabilitation on weight bearing during lower extremity lengthening with Ilizarov method
    Konieczny, Grzegorz
    Morasiewicz, Piotr
    Kuciel, Natalia
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2017, 19 (02) : 59 - 64
  • [9] Weight-Bearing CT Imaging of the Lower Extremity
    Tuominen, Esa K. J.
    Kankare, Jussi
    Koskinen, Seppo K.
    Mattila, Kimmo T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (01) : 146 - 148
  • [10] Inexpensive Virtual Assisted Rehabilitation System (VARS) for Lower Part Injuries
    Bayan, Samar
    Assaf, Kamilia
    Yassin, Marwa
    Cherry, Ali
    Raad, Mohamad
    Hamawy, Lara
    2017 FOURTH INTERNATIONAL CONFERENCE ON ADVANCES IN BIOMEDICAL ENGINEERING (ICABME), 2017, : 45 - 48