Validation of a software-based stability assessment system for wheelchairs and their occupants

被引:3
|
作者
Swansea Rehabilitation Engineering Unit, Morriston Hospital, Swansea, SA6 6NL, United Kingdom [1 ]
机构
来源
J. Med. Eng. Technol. | 2008年 / 6卷 / 440-447期
关键词
Anthropometric test dummies - Centre of gravity - Health and safety issues - ISO 7176-1 - Pearson correlation coefficients - Stability assessment - Static stability - Tipping angle;
D O I
10.1080/03091900701456670
中图分类号
学科分类号
摘要
Injuries relating to unstable wheelchairs are frequent and can be serious. Current physical tilt testing methods for wheelchairs and their occupants present health and safety issues for both testers and wheelchair users. In this study, a comparison was made between a software-based wheelchair stability assessment technique and physical tilting of wheelchairs on an inclined ramp. One manual and one powered wheelchair were studied loaded with a Hybrid II anthropometric test dummy. The software system's performance was assessed for both ideal clinical use and domiciliary use where floors may not be perfectly level. Close correlation was shown between the two systems for both level and unlevel floors; Pearson correlation coefficient 0.75-0.97. Repeatability was demonstrated with a standard deviation range of 0.1 to 0.7. In the majority of cases, the software assessed stability angle was less than the recorded tipping angle, reflecting a factor of safety. © 2008 Informa Healthcare USA, Inc.
引用
收藏
相关论文
共 50 条
  • [1] Validation of the objective assessment of facial movement with a new software-based system
    Monini, Simonetta
    Filippi, Chiara
    Marinozzi, Franco
    di Traglia, Mario
    Bini, Fabiano
    Marchelletta, Silvia
    Ferraioli, Mario
    Margani, Valerio
    Marinelli, Alessia
    Barbara, Maurizio
    ACTA OTO-LARYNGOLOGICA, 2019, 139 (05) : 456 - 460
  • [2] VALIDATION OF ULTRAHIGH DEPENDABILITY FOR SOFTWARE-BASED SYSTEMS
    LITTLEWOOD, B
    STRIGINI, L
    COMMUNICATIONS OF THE ACM, 1993, 36 (11) : 69 - 80
  • [3] Software-based simulation for preprocedural assessment of braided stent sizing: a validation study
    Joshi, Krishna Chaitanya
    Larrabide, Ignacio
    Saied, Ahmed
    Elsaid, Nada
    Fernandez, Hector
    Lopes, Demetrius K.
    JOURNAL OF NEUROSURGERY, 2019, 131 (05) : 1423 - 1429
  • [4] Software-Based Testing for System Peripherals
    M. Grosso
    W. J. Perez Holguin
    E. Sanchez
    M. Sonza Reorda
    A. Tonda
    J. Velasco Medina
    Journal of Electronic Testing, 2012, 28 : 189 - 200
  • [5] Software-Based Testing for System Peripherals
    Grosso, M.
    Perez Holguin, W. J.
    Sanchez, E.
    Reorda, M. Sonza
    Tonda, A.
    Velasco Medina, J.
    JOURNAL OF ELECTRONIC TESTING-THEORY AND APPLICATIONS, 2012, 28 (02): : 189 - 200
  • [6] Software-based speech recognition system
    Yamada, Tomokazu
    Noda, Yoshiaki
    Imoto, Takashi
    Sagayama, Shigeki
    NTT R and D, 1995, 44 (11): : 43 - 47
  • [7] SOFTWARE-BASED DISPLAY SYSTEM FOR VISUAL EXPERIMENTS
    KELLY, DH
    EVANS, WE
    DAWSON, CH
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1982, 72 (12) : 1757 - 1757
  • [8] Validation of a novel software-based platform to extract oculometric measures
    Rosset, Israel
    Raveh, Eitan
    Ben Shimon, Assaf
    Anisimov, Vova
    Ben-Ami, Edmund
    Kreitman, Rivka
    Breakstone, Micha
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [9] Dependability assessment of software-based systems: State of the art
    Liftlewood, B
    ICSE 05: 27th International Conference on Software Engineering, Proceedings, 2005, : 6 - 7
  • [10] Categorization Constructionist Assessment with Software-Based Affinity Diagramming
    Mohamedally, Dean
    Zaphiris, Panayiotis
    INTERNATIONAL JOURNAL OF HUMAN-COMPUTER INTERACTION, 2009, 25 (01) : 22 - 48