SSR characteristics of a wind farm connected to series-compensated transmission system under all operation region of DFIG

被引:0
|
作者
Dong, Xiaoliang [1 ]
Xie, Xiaorong [1 ]
Liu, Hui [2 ]
Li, Yu [2 ]
Han, Yingduo [1 ]
机构
[1] State Key Lab of Control and Simulation of Power Systems and Generation Equipments, Dept. of Electrical Engineering, Tsinghua University, Haidian District, Beijing,100084, China
[2] North China Electric Power Research Institute, Xicheng District, Beijing,100045, China
来源
关键词
Electric power system interconnection - Electric power transmission - Electric utilities - Signal analysis - Time domain analysis - Wind turbines - Eigenvalues and eigenfunctions - Electric fault currents - Asynchronous generators - Time series analysis;
D O I
10.13335/j.1000-3673.pst.2014.09.018
中图分类号
学科分类号
摘要
In most literatures related to subsynchronous resonance (SSR) in doubly fed induction generator (DFIG) based wind farm connected to series-compensated transmission system, the research is on the basis that the wind turbine is operated within the maximum power point tracing (MPPT) operating region, so the obtained conclusions are not comprehensive, since there are other important operating regions of DFIG such as fixed speed operating region, constant power operating region and so on. Firstly, all operating regions of DFIG are analyzed; then taking actual parameters and operating modes of wind turbine in a certain wind farm located in North China as the prototype, a small-signal model and PSCAD simulation model of single machine infinite bus system composed of DFIG and infinite bus system are built, and then using eigenvalue analysis and time-domain simulation the SSR Characteristics of a wind farm connected to series-compensated transmission system under all operation region of DFIG are researched and the SSR stable area are attained. Simulation results show that under low wind speed the SSR phenomenon will occur whether the DFIG is operated in MPPT region or in other operating regions; with the increase of the wind speed the area of stable operation region of DFIG gradually increases. On this basis, several rational suggestions on the stable operation of actual wind farms are put forward.
引用
收藏
页码:2429 / 2433
相关论文
共 50 条
  • [1] A Mechanism Study of SSR for Multiple DFIG Wind Generators Connected to a Series-Compensated Power System
    Xie, Xiaorong
    Wang, Liang
    Liu, Hui
    Liu, Huakun
    Li, Yu
    2014 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2014,
  • [2] Investigation of SSR in Practical DFIG-Based Wind Farms Connected to a Series-Compensated Power System
    Wang, Liang
    Xie, Xiaorong
    Jiang, Qirong
    Liu, Hui
    Li, Yu
    Liu, Huakun
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2015, 30 (05) : 2772 - 2779
  • [3] Fast Detection of SSR for Wind Parks Connected to Series-Compensated Transmission Systems
    Seyedi, Younes
    Mahseredjian, Jean
    Karimi, Houshang
    Karaagac, Ulas
    Trevisan, Aramis Schwanka
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 211
  • [4] Supplementary Controller Design for SSR Damping in a Series-Compensated DFIG-Based Wind Farm
    Wu, Zaijun
    Zhu, Chanxia
    Hu, Minqiang
    ENERGIES, 2012, 5 (11) : 4481 - 4496
  • [5] SSR-Stable Area Analysis of DFIG Based Wind Farms Connected to Series-Compensated Power System
    Dong, Xiaoliang
    Luo, Yazhou
    Liu, Jian
    Geng, Lin
    Zhang, Lei
    Tian, Xu
    2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,
  • [6] Adaptive Fuzzy Supplementary Controller for SSR Damping in a Series-Compensated DFIG-Based Wind Farm
    Abdeen, Mohamed
    El-Banna, Sayed Hosny Ahmed
    Elgohary, Sara
    Mostafa, Hend
    Ghaly, Nora
    Adel, Nourhan
    Elkhwas, Zeinab
    Alahmady, Mohamed
    Zawbaa, Hossam M.
    Kamel, Salah
    IEEE ACCESS, 2023, 11 : 1467 - 1476
  • [7] SSR in Double-Cage Induction Generator-Based Wind Farm Connected to Series-Compensated Transmission Line
    Varma, Rajiv K.
    Moharana, Akshaya
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (03) : 2573 - 2583
  • [8] Analysis of SSR characteristics in DFIGs based wind farm integrated to a series-compensated network
    Wang, Long
    Huang, Biyue
    Sun, Haishun
    Chen, Yahao
    Liu, Yuming
    JOURNAL OF ENGINEERING-JOE, 2019, (18): : 4858 - 4863
  • [9] SSR Mitigation in Wind Farm Connected to Series Compensated Transmission Line using STATCOM
    Moharana, Akshaya
    Varma, Rajiv K.
    Seethapathy, Ravi
    2012 IEEE POWER ELECTRONICS AND MACHINES IN WIND APPLICATIONS (PEMWA), 2012,
  • [10] Back-Up Protection Scheme for Series-Compensated Transmission Line Connected to Wind Farm
    Paul, Monideepa
    Nath, Sudipta
    IETE JOURNAL OF RESEARCH, 2023, 69 (12) : 9217 - 9234