On-line Monitoring Technology of Inter-turn Short Circuit Fault of Dry-type Air-core Reactor

被引:0
|
作者
Huang X. [1 ]
Zhou Y. [1 ]
Zhu Y. [1 ]
Cao W. [1 ]
Zhang L. [1 ]
Wu H. [1 ]
机构
[1] College of Electronics and Information, Xi'an Polytechnic University, Xi'an
关键词
Dry-type air-core reactor; Fundamental harmonic separation algorithm; Inter-turn short circuit fault; On-line monitoring; Power angle;
D O I
10.7500/AEPS20180113001
中图分类号
学科分类号
摘要
The fault model of the inter-turn short circuit of the dry-type air-core reactor is firstly analyzed in this paper, by which an on-line monitoring method of the reactor inter-turn insulation fault based on the changed power angle is proposed. The accuracy of power angle measurement is vital for diagnosing the reactor inter-turn insulation fault. The influence of the frequency fluctuation and harmonic interference on measuring power angle is analyzed by comparing the errors of fast Fourier transformation (FFT), Hanning windowed interpolation FFT and fundamental harmonic separation algorithm improved by Hanning windowed interpolation. An on-line monitoring system of the reactor inter-turn insulation fault is also designed, which consists of the monitoring device, the intelligent electronic device (IED) of dry-type air-core reactor and the expert software. The experiment results show that the fundamental harmonic separation algorithm improved by Hanning windowed interpolation is superior to FFT and Hanning windowed interpolation FFT, and the inter-turn short circuit of the dry-type air-core reactor can be detected precisely by the on-line monitoring system. © 2019 Automation of Electric Power Systems Press.
引用
收藏
页码:150 / 155and181
相关论文
共 27 条
  • [1] Liu H., Wang Y., Gao Z., Et al., Feasibility analysis of impedance monitoring method for turn-to-turn insulation fault of dry-type air-core reactor, 2016 International Conference on Condition Monitoring and Diagnosis (CMD), pp. 152-155
  • [2] Huang X., On-line Monitoring System and Fault Diagnosis of Substation Equipment, (2013)
  • [3] Wang Z., Liu M., Zou J., Et al., Diagnostic method of dry-type air-core reactors overheating fault based on monitoring TVOC, High Voltage Engineering, 11, 43, pp. 3756-3762, (2017)
  • [4] Huang W., Ling Y., Wu Y., Et al., Research on inter-turn short circuit fault characteristics of dry-type air-core reactor, Transformer, 54, 10, pp. 14-18, (2017)
  • [5] Zheng T., Zhao Y., Jin Y., Et al., Analysis on and protective schemes against control winding turn-to-turn fault of magnetic controllable shunt reactors, Automation of Electric Power Systems, 38, 10, pp. 95-99, (2014)
  • [6] Chen S., Wang Z., Zheng Y., Et al., Research & development of a new digital shunt reactor protection, Automation of Electric Power Systems, 27, 24, pp. 70-73, (2003)
  • [7] Bi D., Wang X., Wang W., Measured impedance based shunt reactor protection against small inter-turn fault, Automation of Electric Power Systems, 29, 3, pp. 57-60, (2005)
  • [8] Wang N., Lu F., Li Y., Et al., Calculation of tan δ based on correlation function algorithm, Journal of North China Electric Power University (Natural Science Edition), 28, 3, pp. 22-25, (2001)
  • [9] Xu Z., Lu F., Li H., Dielectric loss angle algorithm considering impulsive noise, Electric Power Automation Equipment, 28, 2, pp. 45-48, (2008)
  • [10] Chen P., He J., Zhao S., Et al., A study of on-line monitoring measurement of tg δ, High Voltage Engineering, 20, 4, pp. 36-38, (1994)