Improvement of indoor thermal environment of rural residences with coupled heating of attached sunspace and energy saving hot-wall

被引:0
|
作者
Chen M. [1 ]
Shi Y. [2 ]
机构
[1] College of Architecture Engineering, Qingdao Agricultural University
[2] College of Horticulture, Qingdao Agricultural University
关键词
Attached sunspace; Couplings; Energy efficiency; Heating; Saving hot-wall;
D O I
10.3969/j.issn.1002-6819.2011.11.044
中图分类号
学科分类号
摘要
The attached sunspace and saving hot-wall was built in rural residences of Qingdao, which aims to improve the indoor thermal environment in winter. The variation regularity of indoor temperature with outdoor weather conditions was studied according to monitoring the data of experimental house, which was a coupled heating of attached sunspace and saving hot-wall combination and the contrast house with same structure, such as room temperature and outdoor temperature, etc. The results showed that the average air temperature in coupled heating house was higher than that in the contrast house by 10.1°C, and the maximum temperature difference reached 13.2°C, the lowest temperature difference was only 5.4°C. Through analysis of energy saving fraction, it was found that energy saving fraction of coupled heating house was high. It was feasible and economic to transform the attached sunspace and saving hot-wall in this area.
引用
收藏
页码:232 / 235
页数:3
相关论文
共 15 条
  • [1] Zheng Z., Li Y., Yang X., Study on energy efficiency of rural residential building in Beijing, Building Science, 24, 4, pp. 9-14, (2008)
  • [2] Zhi Z., Li Y., Chen B., Et al., Chinese Kang as a domestic heating system in rural Northern China: A review, Energy and Buildings, 41, 1, pp. 111-119, (2009)
  • [3] Zhuang Z., Li Y., Chen B., Thermal storage performance analysis on Chinese Kangs, Energy and Buildings, 41, 4, pp. 452-459, (2009)
  • [4] Feng G., Jiang K., Liu B., Numerical Simulation of Suspended Kang, Huoqiang, radiator heating-room Under the two Layouts, Energy-Saving Building, 37, 1, pp. 33-35, (2009)
  • [5] Warrington R.O., Ameel T.A., Experimental studies natural convection in partitioned enclosures with a Trombe wall geometry, Solar Energy Trans ASME, 117, 1, pp. 16-21, (1995)
  • [6] Zamora B., Kaiser A., Thermal and dynamic optimization of the convective flow in Trombe Wall shaped channels by numerical investigation, Heat and Mass Transfer, 45, 11, pp. 1393-1407, (2009)
  • [7] Zhao J., Chen B., Wang Y., Et al., Investigation of dynamic thermal characteristics of passive solar heating system, Journal of Dalian University of Technology, 48, 4, pp. 580-586, (2008)
  • [8] Yang Z., Xu X., Han J., Study on the thermal performance of solar wall, Acta Energiae Solaris Sinica, 28, 10, pp. 1091-1096, (2007)
  • [9] Ye H., Ge X., Dynamic simulations of several solar houses with different composite Trombe - Michel walls and the compare of their thermal performances, Acta Energiae Solaris Sinica, 21, 4, pp. 349-357, (2000)
  • [10] Zhang J., Zhou W., Ding S., Experimental study on heating of passive solar house, Acta Energiae Solaris Sinica, 28, 8, pp. 861-864, (2007)