摘要
The orientation errors of an alt-alt photoelectric telescope are analyzed to determine the effects of the main errors of telescope on measuring accuracy and to improve the pointing precision. By analyzing optical, mechanical and electrical errors from a measured target to the telescope picture, the measuring equations of alt-alt telescope are established. Then, by using Monte Carlo method, the orientation errors are forecasted and the sensitivity of errors to pointings is analyzed. Furthermore, an error correction model is built based on the high sensitivity errors. The result of correction test indicates that the standard error of the longitude axis rotation angle has reduced by 95% from 66.4″ to 3.3″, and that of the latitude axis rotation angle has reduced by 89% from 49.4″ to 5.6″. These results show that the model and the method not only can analyze and synthesize the main errors, but also can provide a reference for the whole design.
引用
收藏
页码:1595 / 1604
页数:9
相关论文
共 10 条
  • [1] Richardson E.H., Grundmann W.A., Odgers G.J., Altitude-altitude (alt-alt) mounting for an 8-metre telescope, SPIE, 1236, pp. 897-904, (1990)
  • [2] Stefan S., Rodrigo A., Philippe D., Et al., VLT astronomical site monitor: Control, automation, and data flow, SPIE, 4009, pp. 338-349, (2000)
  • [3] Han X.B., Zhang J.X., Zhao J.Y., Et al., Guide data fusion arithmetic between the alt-alt theodolite and other target surveying systems, Opt. Precision Eng., 16, SPEC., pp. 30-35, (2008)
  • [4] Zhang J.X., Study on macro-structure of large ground-based electro-optical telescope, pp. 26-31, (2008)
  • [5] Song Y.D., Chen N., Analysis of aclinic mount theodolite tracking structure, Opt. Precision Eng., 16, SPEC., pp. 67-69, (2008)
  • [6] Song Y.D., Wang Z., Chen N., Mechanical precision analysis for the aclinic mount theodolite, Opt. Precision Eng., 16, SPEC., pp. 70-72, (2008)
  • [7] Wang J.Q., Optical Instrument Collectivity Design, pp. 129-169, (1998)
  • [8] Wang J.Q., Jin G., Yan C.X., Orientation error analysis of airborne opto-electric tracking and measuring device, Opt. Precision Eng., 14, 3, pp. 105-116, (2005)
  • [9] Zhao J.Y., Error analysis and correction technology for photoelectricity telescope, pp. 51-60, (2005)
  • [10] Wang J., Gao L.M., Yao J.F., Analysis on coordinate conversion error of airborne measuring device, Opt. Precision Eng., 17, 2, pp. 388-394, (2009)