New Experimental System and Procedure for On-Line Insulation Life Testing of Stator Winding of Automotive Traction PMSM Without Using Dynamo System

被引:1
|
作者
Hayakawa, Teppei [1 ]
Maeda, Yuto [1 ]
Matsumori, Hiroaki [2 ]
Kosaka, Takashi [1 ]
Matsui, Nobuyuki [1 ]
Miyoshi, Yoichi [3 ]
Koga, Kiyotaka [3 ]
Saha, Subrata [4 ]
机构
[1] Nagoya Inst Technol, Nagoya 466855, Japan
[2] Nagoya Inst Technol, Dept Elect & Mech Engn, Nagoya 466855, Japan
[3] Aisin Corp, Adv EV Dev Dept 1, Motor Design Grp, Anjo 4441164, Japan
[4] Aisin Corp, EV Adv Dev Dept 1, Anjo 4441164, Japan
关键词
Automotive traction applications; insulation; motor windings; on-line insulation life test; partial discharge; MONITORING OFF-LINE; IMPULSIVE VOLTAGE; INDUCTION-MOTORS; ELECTROMAGNETIC-WAVES; PARTIAL DISCHARGES; PD;
D O I
10.1109/TIA.2024.3403979
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper proposes an experimental procedure using a new experimental system for on-line insulation turn-to-turn life testing of a stator winding without a rotor of a permanent magnet synchronous motor. Without using any expensive large capacity dynamo set-up, the proposed system and procedure make it possible to test the insulation life of the stator winding under steady state operation of the motor even though at high temperatures of more than 200 degrees C. The line-to-line surge voltage applied to the motor under the inverter's PWM control at the running state of the motor is successfully replicated by the proposed static system. Suitable control blocks are given to describe the experimental procedure for an automotive traction application. In the new experimental set-up, a twisted pair (TP) winding is connected between the U-V phase of the stator phase windings. The turn-to-turn insulation life of the TP windings is approximately estimated by measuring the capacitance of the TP windings at regular time intervals during the on-line testing. Finally, an experiment is carried out to detect the partial discharge in the TP windings and understand the physical relationship that exists between the total partial discharge count number and the decrease in capacitance of the TP windings after a specified time-period of insulation life testing.
引用
收藏
页码:6684 / 6693
页数:10
相关论文
共 4 条
  • [1] New Experimental System and Procedure for On-line Insulation Life Testing of Stator Winding of Automotive Traction PMSM without using Dynamo System
    Hayakawa, Teppei
    Maeda, Yuto
    Matsumori, Hiroaki
    Kosaka, Takashi
    Matsui, Nobuyuki
    Miyoshi, Yoichi
    Koga, Kiyotaka
    Saha, Subrata
    2022 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2022,
  • [2] Experimental Testing of a Traction Control System with On-line Road Condition Estimation for Electric Vehicles
    Vasiljevic, Goran
    Griparic, Karlo
    Bogdan, Stjepan
    2013 21ST MEDITERRANEAN CONFERENCE ON CONTROL AND AUTOMATION (MED), 2013, : 296 - 302
  • [3] New on-line ultrasonic testing system using chirp pulse compression processing
    Okuno, R
    Iizuka, Y
    Nagamune, A
    Nishifuji, K
    TRENDS IN NDE SCIENCE AND TECHNOLOGY - PROCEEDINGS OF THE 14TH WORLD CONFERENCE ON NDT (14TH WCNDT), VOLS 1-5, 1996, : 541 - 544
  • [4] A new simple procedure to calculate monomer reactivity ratios by using on-line 1H NMR kinetic experiments:: Copolymerization system with greater difference between the monomer reactivity ratios
    Abdollahi, Mahdi
    Sharifpour, Maryam
    POLYMER, 2007, 48 (01) : 25 - 30