Exergy analysis of the triple effect parallel flow water-lithium bromide absorption chiller with three condensers

被引:0
|
作者
机构
[1] Sedigh, S.
[2] Saffari, H.
来源
Saffari, H. (saffari@iust.ac.ir) | 1600年 / Sharif University of Technology卷 / 20期
关键词
Temperature;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Exergy analysis of the triple effect parallel flow water-lithium bromide absorption chiller with three condensers
    Sedigh, S.
    Saffari, H.
    SCIENTIA IRANICA, 2013, 20 (04) : 1202 - 1212
  • [2] Energy and exergy analysis of single effect and series flow double effect water-lithium bromide absorption refrigeration systems
    Kaushik, S. C.
    Arora, Akhilesh
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (06): : 1247 - 1258
  • [3] Optimization and comprehensive exergy-based analyses of a parallel flow double-effect water-lithium bromide absorption refrigeration system
    Bagheri, B. Safarnezhad
    Shirmohammadi, R.
    Mahmoudi, S. M. S.
    Rosen, M. A.
    APPLIED THERMAL ENGINEERING, 2019, 152 : 643 - 653
  • [4] Multi-objective optimization of double effect series and parallel flow water-lithium chloride and water-lithium bromide absorption refrigeration systems
    Konwar, D.
    Gogoi, T. K.
    Das, A. J.
    ENERGY CONVERSION AND MANAGEMENT, 2019, 180 : 425 - 441
  • [5] Parametric study and exergy analysis of solar water-lithium bromide absorption cooling system
    Touaibi, Rabah
    Feidt, Michel
    Vasilescu, Elena Eugenia
    Abbes, Miloud Tahar
    INTERNATIONAL JOURNAL OF EXERGY, 2013, 13 (03) : 409 - 429
  • [6] Use of Exergy Analysis to Quantify the Effect of Lithium Bromide Concentration in an Absorption Chiller
    Lake, Andrew
    Rezaie, Behanz
    Beyerlein, Steven
    ENTROPY, 2017, 19 (04):
  • [7] Performance comparison of double-effect parallel-flow and series flow water-lithium bromide absorption systems
    Arun, MB
    Maiya, MP
    Murthy, SS
    APPLIED THERMAL ENGINEERING, 2001, 21 (12) : 1273 - 1279
  • [8] Modeling an integral dual solar/gas fired generator for a water-lithium bromide absorption chiller
    Department of Mechanical Engineering, Ohio State University, Columbus, OH 43210, United States
    ASME Adv Energy Syst Div Publ AES, (159-165):
  • [9] Modeling an integral dual solar/gas-fired generator for a water-lithium bromide absorption chiller
    Cao, J
    Christensen, RN
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2000, 122 (04): : 217 - 223
  • [10] Global modeling of heat and mass transfers in spiral tubular absorber of a water-lithium bromide absorption chiller
    Nabil, Ben Hafsia
    Bechir, Chaouachi
    Slimane, Gabsi
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 38 : 323 - 332