Evaluation of the performance of different internal insulation systems in real-life conditions - A case study

被引:0
|
作者
Pagoni, Panagiota [1 ]
Moller, Eva Birgit [1 ]
Peuhkuri, Ruut Hannele [2 ]
Jensen, Nickolaj Feldt [2 ]
机构
[1] Tech Univ Denmark, Brovej 118, DK-2800 Lyngby, Denmark
[2] Aalborg Univ, AC Meyers Vaenge 15, DK-2450 Copenhagen, Denmark
关键词
Internal insulation; Retrofitting; Masonry; Historic building; Mold growth; Dynamic simulations; HISTORIC SOLID MASONRY; WOODEN BEAM ENDS; HYGROTHERMAL PERFORMANCE; INTERIOR INSULATION; THERMAL INSULATION; BRICK WALL; RETROFIT; IMPACT;
D O I
10.1016/j.buildenv.2024.112319
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Thermal retrofitting of historic buildings is essential to reducing heat loss in all buildings. Although exterior insulation often is hygrothermally a better solution, internal insulation is the only option in facades worthy of preservation (e.g., solid masonry external walls). However, mold growth has frequently been discovered in buildings with internal insulation at the interface between the insulation and the original wall, while simulations and lab tests show minimum risk, and vice versa. Therefore, real-life testing is required so that the building owners are more likely to accept these measures. This paper presents a case study of an 1837-built typical historic building. The study focuses on the building's top floor, a residential area (commune). Eight different rooms have four different types of internal insulation installed. The performance of the insulation systems was determined by monitoring the interior and exterior climate and the temperature and relative humidity at the intersection of the insulation and the existing wall for 20 months. The risk of mold growth was estimated based on the measurements. In the wall interfaces, the Mold Index indicated that the risk for mold growth is not severe. Hygrothermal simulations for the measured period and ten years were also performed. To increase simulation accuracy, the original exterior masonry bricks underwent laboratory testing to determine their precise material properties. The main outcome from the simulations was that the three vapor-open systems were more susceptible to indoor moisture load changes and had an elevated risk of mold growth, whereas the vapor-tight system was more robust to variation in insulation thickness and internal moisture level changes, and in this case, demonstrated the best performance in respect to moisture safety.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] EVALUATION OF HEAT PUMP EFFICIENCY IN REAL-LIFE CONDITIONS. A CASE STUDY.
    Brezeanu, Alin Ionut
    Dragomir, George
    Serban, Alexandru
    Nastase, Gabriel
    ENERGY AND CLEAN TECHNOLOGIES CONFERENCE PROCEEDINGS, SGEM 2016, VOL I, 2016, : 355 - 360
  • [2] SELECTING A DBMS FOR LARGE SYSTEMS - A REAL-LIFE CASE-STUDY
    OXMAN, SW
    DATA MANAGEMENT, 1984, 22 (10): : 31 - 39
  • [3] Standardised evaluation of three continuous glucose monitoring systems mimicking real-life conditions
    Aberer, F.
    Hajnsek, M.
    Rumpler, M.
    Zenz, S.
    Puffing, A.
    Augustin, T.
    Baumann, P.
    Sinner, F.
    Sourijl, H.
    Pieber, T. R.
    Mader, J. K.
    DIABETOLOGIA, 2016, 59 : S411 - S412
  • [4] Numerical Evaluation of the Hygrothermal Performance of a Capillary Active Internal Wall Insulation System under Different Internal Conditions
    Kaczorek, Dobroslawa
    MATERIALS, 2022, 15 (05)
  • [5] Evaluation of rofecoxib in patients with osteoarthritis under real-life conditions - The valor study in Colombia
    Forero, JH
    Alfonso, R
    Arabelaez, F
    Hunsche, E
    Kong, SX
    ANNALS OF THE RHEUMATIC DISEASES, 2003, 62 : 540 - 540
  • [6] Spontaneous Scaling of a Primary Care Innovation in Real-Life Conditions: Protocol for a Case Study
    Legare, France
    Mochcovitch, Diogo G., V
    Coroa, Roberta de Carvalho
    Gogovo, Amede
    Ben Charif, Ali
    Cameron, Cynthia
    Plamondon, Annie
    Cimon, Marie
    Guay-Belanger, Sabrina
    Roch, Genevieve
    Pilon, Maxine Dumas
    Paquette, Jean-Sebastien
    McLean, Robert K. D.
    Milat, Andrew
    JMIR RESEARCH PROTOCOLS, 2023, 12
  • [7] Use and performance of non-invasive ventilation in Internal Medicine ward a real-life study
    Ventrella, Francesco
    Giancola, Armando
    Cappello, Sergio
    Pipino, Maria
    Minafra, Graziano
    Carbone, Mattea
    Caccetta, Luigi
    Insalata, Maria
    Iamele, Luigi
    ITALIAN JOURNAL OF MEDICINE, 2015, 9 (03) : 260 - 267
  • [8] Real-life CRONOS evaluation
    Boillot, F
    Midenet, S
    Pierrelée, JC
    TENTH INTERNATIONAL CONFERENCE ON ROAD TRANSPORT INFORMATION AND CONTROL, 2000, (472): : 182 - 186
  • [9] Performance of child restraint systems in real-life lateral collisions
    Langwieder, K
    Hell, W
    Willson, H
    40TH STAPP CAR CRASH CONFERENCE PROCEEDINGS, 1996, P-30 : 391 - 404
  • [10] Evaluation of FISH for Blood Cultures under Diagnostic Real-Life Conditions
    Reitz, Annalena
    Poppert, Sven
    Rieker, Melanie
    Frickmann, Hagen
    EUROPEAN JOURNAL OF MICROBIOLOGY AND IMMUNOLOGY, 2018, 8 (04): : 135 - 141