The impact of accuracy of calculations of inductive diaphragm parameters on the accuracy of multiresonance method for measurement of waveguide reflection factor

被引:0
|
作者
Ponomarenko, V.I. [1 ]
Popov, V.V. [1 ]
机构
[1] Tavrichesky National University, Simferopol, Ukraine
关键词
Approximation theory - Computer aided analysis - Electromagnetic wave diffraction - Electromagnetic wave reflection - Mathematical transformations - Resonance;
D O I
暂无
中图分类号
学科分类号
摘要
The paper compares the approximate and strict solution of the problem of diffraction on a waveguide-type inductive diaphragm of a finite thickness. Computer-aided simulation permits to estimate the impact of the diaphragm parameter computational error on accuracy of the multiresonance method. A transform is suggested making it possible to improve accuracy of the approximate quasistatic solution used in the multiresonance method for calculation of the reflection factor in a waveguide. © 2007 by Allerton Press, Inc.
引用
收藏
页码:50 / 53
相关论文
共 49 条
  • [1] Compensation of experimental errors in the multiresonance method of measurement of reflection factor in a waveguide
    Tavrichesky National University, Simferopol, Ukraine
    Radioelectron. Commun. Syst., 2006, 8 (47-50):
  • [2] Method of improving measurement accuracy of Stokes parameters
    Bu, Y. (buyang@siom.ac.cn), 1600, Science Press (40):
  • [3] Study on the Parameters Affecting the Impedance Extraction Accuracy by Inductive Coupling Method
    Narayanan, Arun Shankar
    Zhao, Zhenyu
    Chua, Eng Kee
    Weerasinghe, Arjuna
    See, Kye Yak
    Junitra, Kennard
    Koh, Boon Kai
    2018 INTERNATIONAL CONFERENCE ON INTELLIGENT RAIL TRANSPORTATION (ICIRT), 2018,
  • [4] VERIFICATION OF PARAMETERS OF TOTAL STATION ACCURACY BY DISTANCE MEASUREMENT WITH A PASSIVE REFLECTION
    Franek, Pavel
    Cernota, Pavel
    Stankova, Hana
    Neustupa, Zdenek
    Frankova, Hana
    12TH INTERNATIONAL MULTIDISCIPLINARY SCIENTIFIC GEOCONFERENCE, SGEM 2012, VOL. II, 2012, : 837 - +
  • [5] THE IMPACT OF INTERPOLATION METHOD PARAMETERS ON THE ACCURACY OF PREDICTED VALUES
    Vyciene, Gitana
    Grybauskiene, Vilda
    RESEARCH FOR RURAL DEVELOPMENT 2013, VOL 2, 2013, : 141 - 147
  • [6] The impact of interpolation method parameters on the accuracy of predicted values
    Vyčiene, Gitana
    Grybauskiene, Vilda
    Vyčiene, G. (gitana.vyciene@asu.lt), 1600, Jelgava : Latvia University of Agriculture (02): : 141 - 147
  • [7] Uncertainty Evaluation for the Impact of Measurement Accuracy on Power Quality Parameters
    Gasch, Etienne
    Domagk, Max
    Stiegler, Robert
    Meyer, Jan
    2017 IEEE INTERNATIONAL WORKSHOP ON APPLIED MEASUREMENTS FOR POWER SYSTEMS (AMPS), 2017, : 134 - 139
  • [8] Reflection-mode digital gradient sensing method: measurement accuracy
    Miao, Chengyun
    Tippur, Hareesh, V
    OPTICAL ENGINEERING, 2019, 58 (04)
  • [9] REFLECTION FACTOR FOR AN H10-WAVE INCIDENT ON AN ASYMMETRICAL INDUCTIVE DIAPHRAGM IN A RECTANGULAR WAVEGUIDE WITH A SYSTEM OF RADIOTRANSPARENT FILMS
    ZABOLOTI.YP
    RADIO ENGINEERING AND ELECTRONIC PHYSICS-USSR, 1967, 12 (06): : 921 - &
  • [10] Impact of sampling frequency on accuracy of unbalance factor measurement by DFT
    Tarasiuk, Tomasz
    Pilat, Andrzej
    2015 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2015, : 1420 - 1424