Comparative Techno-Economic Analysis of Parabolic Trough and Linear Fresnel Collectors with Evacuated and Non-Evacuated Receiver Tubes in Different Geographical Regions

被引:1
|
作者
Shokrnia, Mehdi [1 ]
Cagnoli, Mattia [2 ]
Grena, Roberto [2 ]
D'Angelo, Antonio [3 ]
Lanchi, Michela [2 ]
Zanino, Roberto [1 ]
机构
[1] Politecn Torino, Dipartimento Energia, Corso Duca Abruzzi 24, I-10129 Turin, Italy
[2] ENEA Res Ctr, Via Anguillarese 301, I-00123 Rome, Italy
[3] ENEA, Port Res Ctr, Piazzale Enr Fermi 1, I-80055 Naples, Italy
关键词
CSP; Parabolic Trough Collector (PTC); Linear Fresnel Collector (LFC); techno-economic analysis; numerical modelling; SOLAR POWER-PLANTS; PERFORMANCE; OPTIMIZATION; ENERGY;
D O I
10.3390/pr12112376
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In the context of Concentrated Solar Power (CSP) technology, this paper presents a comparison between the Parabolic Trough Collector (PTC) and the Linear Fresnel Collector (LFC), considering both evacuated and non-evacuated receiver tubes. The comparison was carried out in terms of the Levelized Cost of Electricity (LCOE) considering a reference year and four locations in the world, characterized by different levels of direct normal irradiation (DNI) from 2183 kWh/m2/year to 3409 kWh/m2/year. The LCOE depends on economic parameters and on the net energy generated by a plant on an annual basis. The latter was determined by a steady-state 1D model that solved the energy balance along the receiver axis. This model required computing the incident solar power and heat losses. While the solar power was calculated by an optical ray-tracing model, heat losses were computed by a lumped-parameter model developed along the radial direction of the tube. Since the LFC adopted a secondary concentrator, no conventional correlation was applicable for the convective heat transfer from the glass cover to the environment. Therefore, a 2D steady-state CFD model was also developed to investigate this phenomenon. The results showed that the PTC could generate a higher net annual energy compared to the LFC due to a better optical performance ensured by the parabolic solar collector. Nevertheless, the difference between the PTC and the LFC was lower in the non-evacuated tubes because of lower heat losses from the LFC receiver tube. The economic analysis revealed that the PTC with the evacuated tube also achieved the lowest LCOE, since the higher cost with respect to both the LFC system and the non-evacuated PTC was compensated by the higher net energy yield. However, the non-evacuated LFC demonstrated a slightly lower LCOE compared to the non-evacuated PTC since the lower capital cost of the non-evacuated LFC outweighed its lower net annual energy yield. Finally, a sensitivity analysis was conducted to assess the impact on the LCOE of the annual optical efficiency and of the economic parameters. This study introduces key technical parameters in LFC technology requiring improvement to achieve the level of productivity of the PTC from a techno-economic viewpoint, and consequently, to fill the gap between the two technologies.
引用
收藏
页数:26
相关论文
共 21 条
  • [1] Analysis of the performance of linear Fresnel collectors: Encapsulated vs. evacuated tubes
    Cagnoli, M.
    Mazzei, D.
    Procopio, M.
    Russo, V
    Savoldi, L.
    Zanino, R.
    SOLAR ENERGY, 2018, 164 : 119 - 138
  • [2] Enhancing the Performance of Evacuated and Non-Evacuated Parabolic Trough Collectors Using Twisted Tape Inserts, Perforated Plate Inserts and Internally Finned Absorber
    Bellos, Evangelos
    Tzivanidis, Christos
    ENERGIES, 2018, 11 (05)
  • [3] HEAT LOSS EXPERIMENTS ON A NON-EVACUATED PARABOLIC TROUGH RECEIVER EMPLOYING A THERMALLY INSULATING LAYER IN THE ANNULAR GAP
    Al-Ansary, Hany
    Zeitoun, Obida
    PROCEEDINGS OF THE ASME 7TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2013, 2014,
  • [4] Cooling supply with a new type of evacuated solar collectors: a techno-economic optimization and analysis
    Mavd P. R. Teles
    Meisam Sadi
    Kamal A. R. Ismail
    Ahmad Arabkoohsar
    Brenda V. F. Silva
    Hadi Kargarsharifabad
    Shahin Shoeibi
    Environmental Science and Pollution Research, 2024, 31 : 18171 - 18187
  • [5] Cooling supply with a new type of evacuated solar collectors: a techno-economic optimization and analysis
    Teles, Mavd P. R.
    Sadi, Meisam
    Ismail, Kamal A. R.
    Arabkoohsar, Ahmad
    Silva, Brenda V. F.
    Kargarsharifabad, Hadi
    Shoeibi, Shahin
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 31 (12) : 18171 - 18187
  • [6] Techno-Economic Analysis of Receiver Replacement Scenarios in a Parabolic Trough Field
    Roeger, Marc
    Luepfert, Eckhard
    Caron, Simon
    Dieckmann, Simon
    SOLARPACES 2015: INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS, 2016, 1734
  • [7] Experimental study of productivity progress for a solar still integrated with parabolic trough collectors with a phase change material in the receiver evacuated tubes and in the still
    Dawood, Mohamed M. Khairat
    Nabil, Tamer
    Kabeel, A. E.
    Shehata, Ali I.
    Abdalla, Abdalla M.
    Elnaghi, Basem E.
    JOURNAL OF ENERGY STORAGE, 2020, 32
  • [8] Experimental study of productivity progress for a solar still integrated with parabolic trough collectors with a phase change material in the receiver evacuated tubes and in the still
    Khairat Dawood, Mohamed M.
    Nabil, Tamer
    Kabeel, A.E.
    Shehata, Ali I.
    Abdalla, Abdalla M.
    Elnaghi, Basem E.
    Kabeel, A.E. (kabeel6@f-eng.tanta.edu.eg), 1600, Elsevier Ltd (32):
  • [9] Techno-economic analysis of applying linear parabolic and flat plate solar collectors for heating a building and their comparative evaluation
    Hashemi, Neda Mohammad
    Abdolzadeh, Morteza
    Rahnama, Mohammad
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2019, 38 (04)
  • [10] Comprehensive analysis of the variables influencing the techno-economic optimization of medium temperature linear Fresnel collectors
    Ordonez, Freddy
    Flores, Esteban
    Soria, Rafael
    ENERGY REPORTS, 2021, 7 : 5747 - 5761