Design method and its application in hybrid base-isolation of high-rise buildings

被引:1
|
作者
Du D. [1 ]
Wang S. [1 ]
Liu W. [1 ]
Sun Z. [1 ]
机构
[1] College of Civil Engineering, Nanjing University of Technology
关键词
Compress stress of isolator; Hybrid base-isolation; Performance evaluation; Tension of isolators;
D O I
10.3969/j.issn.1001-0505.2010.05.030
中图分类号
学科分类号
摘要
In order to perfect both theoretical basis and designing foundation for hybrid base-isolation of tall buildings, some key issues about upper structure design for hybrid base-isolation system and isolation layer design, influence from high modes and high damping on isolated effect are investigated. Basic principles of vertical components arrangement for seismic isolation system are proposed, and basic principles of isolation layer design and distribution method of all kinds of isolation devices are analyzed. According to above fundamental theory, performance-based hybrid base-isolation design method is applied to the currently tallest domestic high-rise isolated building. The performance characteristics of purified natural rubber bearing, lead rubber bearing, sliding isolated bearing and viscous damper are fully taken into account. These bearings are equipped in isolation layer, according to the correlative combination principle. The study result indicates that all kinds of isolation devices bring the designed functions into full play. Isolation layer keeps a stable working status under rare earthquake, while seismic response of upper structure declines obviously, and all performance objectives satisfy design requirements. At last, necessary remarks are made for related structural requirements of high-rise isolated structures.
引用
收藏
页码:1039 / 1046
页数:7
相关论文
共 11 条
  • [1] Wang S., Du D., Liu W., Key-problems of seismic isolation structure design in high-rise buildings, Journal of Nanjing University of Technology: Natural Science Edition, 31, 1, pp. 67-72, (2009)
  • [2] Hou B., New developments of seismic isolation and response control technology in Japan, Industrial Construction, 30, 11, pp. 74-78, (2000)
  • [3] (2007)
  • [4] (2008)
  • [5] Du D., Wang S., Liu W., Discussion on the seismic reduction effect of isolated long period high-rise buildings, The 17th National Conference on Civil Engineering.Suzhou, (2008)
  • [6] (2006)
  • [7] Wang S., Du D., Liu W., Et al., Research on seismic influence coefficient of seismic isolated structure with different damping ratio, Journal of Building Structures, 30, 3, pp. 112-113, (2009)
  • [8] Liu W., Yang Q., Zhou F., Simplified method of earthquake response analysis for slender isolated structure, Journal of Earthquake Engineering and Engineering Vibration, 24, 4, pp. 115-121, (2004)
  • [9] Cheng H., Liu W., Wang S., Analysis of the tension of rubber bearings in the design of isolated high-rise buildings, Journal of Earthquake Engineering and Engineering Vibration, 27, 4, pp. 162-164, (2007)
  • [10] (2006)