共 1 条
Evaluation of dental cements derived from mixtures of highly reactive ionomer glasses and bottle glass: Cement manipulation, mechanical, fluoride ion releasing, radiopaque and setting properties
被引:0
|作者:
Osiro, Olivia Awino
[1
,2
]
Tiskaya, Melissa
[3
]
Shahid, Saroash
[3
]
Hill, Robert Graham
[3
]
机构:
[1] Univ Nairobi, Dept Dent Sci, Dent Mat, Nairobi, Kenya
[2] Queen Mary Univ London, Inst Dent, Ctr Oral Growth, Dent Phys Sci Unit, Mile End Rd, London E1 4NS, England
[3] Queen Mary Univ London, Inst Dent, Ctr Oral Bioengn, Dent Mat,Dent Phys Sci Unit, Mile End Rd, London E1 4NS, England
基金:
英国惠康基金;
关键词:
Bottle glass;
Glass ionomer cement;
Fluoride release;
Compressive strength;
Reactive;
Radiopacity;
Setting reaction;
ATRAUMATIC RESTORATIVE TREATMENT;
ACID) MOLAR-MASS;
MINIMAL INTERVENTION DENTISTRY;
SILVER DIAMINE FLUORIDE;
POLYALKENOATE CEMENTS;
STRUCTURAL-CHARACTERIZATION;
PART I;
CARIES;
SURVIVAL;
D O I:
10.1016/j.dental.2024.09.013
中图分类号:
R78 [口腔科学];
学科分类号:
1003 ;
摘要:
Objectives: To evaluate the mechanical properties, fluoride release, radiopacity, and setting characteristics of dental cements derived from highly reactive ionomer glasses and bottle glass mixtures. Methods: Two highly reactive glass series, LG99 and LG117, were synthesized, milled, sieved, and characterized using XRD and laser particle size analysis. These glasses were mixed with predetermined ratios of ground bottle glass, poly(acrylic acid), and aqueous tartaric acid to form glass ionomer cements. The cements' working time (WT), setting time (ST), fluoride release, radiopacity, compressive strength (CS), and elastic modulus (EM) were evaluated. Mean differences in CS were analyzed using multivariate ANOVA with Tukey's post hoc test at p = 0.05. Results: The WT and ST for both groups ranged from 1.5 to 2.5 min. LG99 series cements showed significantly higher CS (similar to 65 MPa) and EM (similar to 2 GPa) than LG117 series (p < 0.05). Both series showed similar fluoride release profiles, peaking at 1.2 mmol/L at 28 days. Radiopacity for LG99 ranged from 0.97 to 1.34, while LG117 ranged from 0.60 to 0.95. Solid state Al-27 magic-angle spinning-nuclear magnetic resonance (MAS NMR) confirmed the presence of Al(IV) and Al(VI), indicating setting completion by one day for both series. Bottle glass showed a chemical shift at 55.8 ppm, overlapping with LG99 ' s Al(IV) signal. The F-19 MAS NMR spectra revealed Al-F and FSr(n) species in all glasses, with LG117 forming CaF2 after one day in deionized water. Conclusion: Mixtures of highly reactive ionomer glass and bottle glass produced cements with satisfactory properties for dental applications. Further research is needed to optimize their formulation and properties.
引用
收藏
页码:1981 / 1990
页数:10
相关论文