摘要
The connection structure of zirconia dental implants significantly influences their biomechanical behavior and plays a crucial role in the overall service performance of the implant system. This study aims to compare the stress distribution of zirconia implants featuring various internal connection structures under different working conditions. Four distinct types of connection structures were designed for zirconia dental implants: triangular, quadrilateral, hexagonal, and hexalobular plus connections. Additionally, the finite element method was employed to analyze these structures under three working conditions: a static load test model, a bone level model, and a torsion model. Results indicated that in the static load test model, the hexagonal structure experienced the highest stress value at 1284.9 MPa due to its thin neck wall, whereas the hexalobular plus connected implant exhibited the lowest stress value at 1252.9 MPa. In the bone level model, the triangular connection structure demonstrated poor stress distribution for cortical bone and cancellous bone at 69.606 MPa and 7.8191 MPa, respectively. Conversely, the hexalobular plus connection yielded superior stress results for cortical bone and cancellous bone, with values of 66.24 MPa and 5.1327 MPa, respectively. In the torsion model, the hexalobular plus-connected implant exhibits the highest stress value at 237.6 MPa, while maintaining the smallest force transmission angle. Therefore, given that the abutment necessitates a greater range of installation angles and improved torque transmission, the hexalobular plus connection structure may represent the optimal choice.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] BIOMECHANICAL INVESTIGATION OF TITANIUM AND ZIRCONIA DENTAL IMPLANTS
    Ruzas, M.
    Sesok, A.
    MECHANIKA, 2017, 23 (04): : 495 - 499
  • [2] STRUCTURE AND PROPERTIES OF DENTAL IMPLANTS
    Greger, Miroslav
    Widomska, Milena
    Snasel, Vaclav
    21ST INTERNATIONAL CONFERENCE ON METALLURGY AND MATERIALS (METAL 2012), 2012, : 434 - 439
  • [3] Biomechanical Properties of Bone and Mucosa for Design and Application of Dental Implants
    Gasik, Michael
    Lambert, France
    Bacevic, Miljana
    MATERIALS, 2021, 14 (11)
  • [4] Mechanical properties and biomechanical compatibility of porous titanium for dental implants
    Asaoka, K.
    Kuwayama, N.
    Okuno, O.
    Miura, I.
    1600, (19):
  • [5] STRUCTURE AND PROPERTIES OF TITANIUM FOR DENTAL IMPLANTS
    Greger, Miroslav
    Kander, Ladislav
    Masek, Vaclav
    NANOCON 2011, 2011, : 594 - 600
  • [6] STRUCTURE AND PROPERTIES OF TITANIUM FOR DENTAL IMPLANTS
    Greger, M.
    Cerny, M.
    Kander, L.
    Kliber, J.
    METALURGIJA, 2009, 48 (04): : 249 - 252
  • [7] Biomechanical evaluation of anterior implants associated with titanium and zirconia abutments and monotype zirconia implants
    Brandao de Holanda, Kelynne Alcantara
    Caldas, Ricardo Armini
    Amaral, Marina
    da Silva Concilio, Lais Regiane
    Vitti, Rafael Pino
    JOURNAL OF PROSTHODONTIC RESEARCH, 2021, 65 (01) : 73 - 77
  • [8] A Comparison Study of the Osseointegration of Zirconia and Titanium Dental Implants. A Biomechanical Evaluation in the Maxilla of Pigs
    Gahlert, Michael
    Roehling, Stefan
    Wieland, Marco
    Eichhorn, Stefan
    Kuechenhoff, Helmut
    Kniha, Heinz
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2010, 12 (04) : 297 - 305
  • [9] Surface characterization of zirconia dental implants
    Zinelis, S.
    Thomas, A.
    Syres, K.
    Silikas, N.
    Eliades, G.
    DENTAL MATERIALS, 2010, 26 (04) : 295 - 305
  • [10] Zirconia Dental Implants: A Literature Review
    Ozkurt, Zeynep
    Kazazoglu, Ender
    JOURNAL OF ORAL IMPLANTOLOGY, 2011, 37 (03) : 367 - 376