Noise-aware dynamic image denoising and positron range correction for Rubidium-82 cardiac PET imaging via self-supervision

被引:0
|
作者
Xie, Huidong [1 ]
Guo, Liang [1 ]
Velo, Alexandre [2 ]
Liu, Zhao [2 ]
Liu, Qiong [1 ]
Guo, Xueqi [1 ]
Zhou, Bo [1 ]
Chen, Xiongchao [1 ]
Tsai, Yu-Jung [2 ]
Miao, Tianshun [2 ]
Xia, Menghua [2 ]
Liu, Yi-Hwa [5 ]
Armstrong, Ian S. [3 ]
Wang, Ge [4 ]
Carson, Richard E. [1 ,2 ]
Sinusas, Albert J. [1 ,2 ,5 ]
Liu, Chi [1 ,2 ]
机构
[1] Yale Univ, Dept Biomed Engn, New Haven, CT USA
[2] Yale Univ, Dept Radiol & Biomed Imaging, New Haven, CT USA
[3] Univ Manchester, DEPT NUCL MED, MANCHESTER, England
[4] Rensselaer Polytech Inst, Dept Biomed Engn, Troy, NY USA
[5] Yale Univ, Dept Internal Med Cardiol, New Haven, CT USA
关键词
Rubidium-82 cardiac PET imaging; Deep learning; Self-supervised learning; Positron range correction; Medical image denoising; MYOCARDIAL BLOOD-FLOW; CORONARY-ARTERY-DISEASE; EMISSION-TOMOGRAPHY; PROGNOSTIC VALUE; PERFUSION; QUANTIFICATION; RECONSTRUCTION; RESERVE; TISSUE;
D O I
10.1016/j.media.2024.103391
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Rubidium-82 (82Rb) is a radioactive isotope widely used for cardiac PET imaging. Despite numerous benefits of 82 Rb, there are several factors that limits its image quality and quantitative accuracy. First, the short halflife of 82 Rb results in noisy dynamic frames. Low signal-to-noise ratio would result in inaccurate and biased image quantification. Noisy dynamic frames also lead to highly noisy parametric images. The noise levels also vary substantially indifferent dynamic frames due to radiotracer decay and short half-life. Existing denoising methods are not applicable for this task due to the lack of paired training inputs/labels and inability to generalize across varying noise levels. Second, 82 Rb emits high-energy positrons. Compared with other tracers such as 18 F, 82 Rb travels a longer distance before annihilation, which negatively affect image spatial resolution. Here, the goal of this study is to propose a self-supervised method for simultaneous (1) noise-aware dynamic image denoising and (2) positron range correction for 82 Rb cardiac PET imaging. Tested on a series of PET scans from a cohort of normal volunteers, the proposed method produced images with superior visual quality. To demonstrate the improvement in image quantification, we compared image-derived input functions (IDIFs) with arterial input functions (AIFs) from continuous arterial blood samples. The IDIF derived from the proposed method led to lower AUC differences, decreasing from 11.09% to 7.58% on average, compared to the original dynamic frames. The proposed method also improved the quantification of myocardium blood flow (MBF), as validated against 15 O-water scans, with mean MBF differences decreased from 0.43 to 0.09, compared to the original dynamic frames. We also conducted a generalizability experiment on 37 patient scans obtained from a different country using a different scanner. The presented method enhanced defect contrast and resulted in lower regional MBF in areas with perfusion defects. Lastly, comparison with other related methods is included to show the effectiveness of the proposed method.
引用
收藏
页数:14
相关论文
共 11 条
  • [1] Self-supervised Positron Range Correction for Dynamic Rubidium-82 Cardiac PET Imaging
    Xie, Huidong
    Velo, Alexandre
    Guo, Xueqi
    Zhou, Bo
    Chen, Xiongchao
    Tsai, Yu-Jung
    Miao, Tianshun
    Liu, Qiong
    Sinusas, Albert
    Liu, Chi
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [2] Resolution Modeled PET Image Reconstruction Incorporating Space-Variance of Positron Range: Rubidium-82 Cardiac PET Imaging
    Rahmim, Arman
    Tang, Jing
    Lodge, Martin A.
    Lashkari, Sarah
    Ay, Mohammad R.
    Bengel, Frank M.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2918 - +
  • [3] Feasibility of positron range correction in 82-Rubidium cardiac PET/CT
    Jensen, Malte
    Bentsen, Simon
    Clemmensen, Andreas
    Jensen, Jacob Kildevang
    Madsen, Johanne
    Rossing, Jonas
    Laier, Anna
    Hasbak, Philip
    Kjaer, Andreas
    Ripa, Rasmus Sejersten
    EJNMMI PHYSICS, 2022, 9 (01)
  • [4] Feasibility of positron range correction in 82-Rubidium cardiac PET/CT
    Malte Jensen
    Simon Bentsen
    Andreas Clemmensen
    Jacob Kildevang Jensen
    Johanne Madsen
    Jonas Rossing
    Anna Laier
    Philip Hasbak
    Andreas Kjaer
    Rasmus Sejersten Ripa
    EJNMMI Physics, 9
  • [5] Automated dynamic motion correction improves repeatability and reproducibility of myocardial blood flow quantification with rubidium-82 PET imaging
    Justen Choueiry
    Neel P. Mistry
    Rob S. B. Beanlands
    Robert A. deKemp
    Journal of Nuclear Cardiology, 2023, 30 : 1133 - 1146
  • [6] Automated dynamic motion correction improves repeatability and reproducibility of myocardial blood flow quantification with rubidium-82 PET imaging
    Choueiry, Justen
    Mistry, Neel P.
    Beanlands, Rob S. B.
    deKemp, Robert A.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2023, 30 (03) : 1133 - 1146
  • [7] Assessment of motion correction in dynamic rubidium-82 cardiac PET with and without frame-by-frame adjustment of attenuation maps for calculation of myocardial blood flow
    Armstrong, Ian S.
    Memmott, Matthew J.
    Saint, Kimberley J.
    Saillant, Antoine
    Hayden, Charles
    Arumugam, Parthiban
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (04) : 1334 - 1346
  • [8] Assessment of motion correction in dynamic rubidium-82 cardiac PET with and without frame-by-frame adjustment of attenuation maps for calculation of myocardial blood flow
    Ian S. Armstrong
    Matthew J. Memmott
    Kimberley J. Saint
    Antoine Saillant
    Charles Hayden
    Parthiban Arumugam
    Journal of Nuclear Cardiology, 2021, 28 : 1334 - 1346
  • [9] Positron range correction improves image quality and enables half-dose imaging for Rb-82 PET MPI
    Dekemp, Robert
    Akbarian, Ramin
    Choueiry, Justen
    Beanlands, Rob
    Panin, Vladimir
    Conti, Maurizio
    Casey, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [10] Standard versus low-dose rubidium-82 dynamic positron emission tomography imaging with scanner-dependent bias correction for myocardial perfusion imaging and blood flow quantification
    Truong, Brenda
    Renaud, Jennifer
    Wang, Tong
    Beanlands, Rob
    DeKemp, Robert
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59