Simultaneous Panoramic Optical Mapping and Multi-channel Stimulation System for Validation of Adaptive Antitachycardia Pacing

被引:0
|
作者
Seno, Hiroshi [1 ]
Ise, Taichi [1 ]
Yamazaki, Masatoshi [1 ,2 ]
Sakuma, Ichiro [1 ]
Tomii, Naoki [1 ]
机构
[1] Univ Tokyo, Grad Sch Engn, Tokyo, Japan
[2] Nagano Hosp, Dept Cardiol, Soja, Japan
来源
关键词
arrhythmia; ventricular fibrillation; low-energy defibrillation; optical mapping; DEFIBRILLATION; OPTIMIZATION; TERMINATION; MECHANISMS; ICD;
D O I
10.14326/abe.13.307
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To achieve low-energy defibrillation for ventricular tachycardia (VT) and fibrillation (VF), an experimental system is essential to investigate appropriate point stimulation protocols. In this study, we developed an experimental system integrating 3D panoramic optical mapping (POM) with an adaptive multi-channel stimulation (AMS) system based on electrocardiogram (ECG) signals. A validation experiment was conducted using an ex vivo rabbit heart. We fabricated patch-shaped transparent bipolar electrodes made of polydimethylsiloxane (PDMS) for measurement and stimulation purposes. In the AMS system, we measured the ECG signals with these electrodes at sampling rate of 1 kHz using an amplifier. These potentials were analyzed using an embedded computer system, which then triggered a multi-channel stimulator for adaptive point stimulations. Reconstruction of the heart shape model and estimation of camera position were achieved using structure from motion and the multi-view stereo algorithm. The 3D POM was obtained by optically projecting captured images acquired from three cameras and calculating membrane potentials. By evaluating the adaptive stimulation delay of the AMS system, we identified a latency of approximately 1.41 +/- 0.23 ms (n = 21). We stimulated an ex vivo rabbit heart using the AMS system combined with the 3D POM. The adaptive stimulation was confirmed to be executed at the intended timing, as indicated by the measured ECG. Additionally, we attempted VT termination by adaptive point stimulations and observed their effect on the original VT using 3D POM. We successfully constructed an experimental system to evaluate various adaptive point stimulation defibrillation protocols.
引用
收藏
页码:307 / 317
页数:11
相关论文
共 50 条
  • [1] Virtual electrode stimulation in a multi-channel stimulation system
    Hoang, Linh
    Zhi, Yang
    Liu, Wentai
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 3894 - 3898
  • [2] Research of Multi-channel Simultaneous Sampling System
    Du Yuyuan
    Xu, Wang
    PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON TEST AUTOMATION & INSTRUMENTATION, VOLS 1-2, 2008, : 1033 - 1036
  • [3] Multi-channel optical mapping: Investigation of depth information
    Sase, I
    Eda, H
    Seiyama, A
    Tanabe, HC
    Takatsuki, A
    Yanagida, T
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE IV, 2001, 4250 : 29 - 36
  • [4] Simultaneous Multi-channel Data Acquisition and Storing System
    Abdallah, Mohammed
    Elkeelany, Omar
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON COMPUTING, ENGINEERING AND INFORMATION, 2009, : 233 - +
  • [5] A SYSTEM FOR THE MULTI-CHANNEL TRANSCUTANEOUS STIMULATION OF THE AURICULAR NERVE
    Rozman, Janez
    Bartolic, Andrej
    Maiga, Aicha Ibrahim
    Ribaric, Samo
    MATERIALI IN TEHNOLOGIJE, 2019, 53 (05): : 627 - 635
  • [6] An adaptive system for direct blind multi-channel equalization
    Choi, SJ
    Luo, H
    Liu, RW
    FIRST IEEE SIGNAL PROCESSING WORKSHOP ON SIGNAL PROCESSING ADVANCES IN WIRELESS COMMUNICATIONS, 1997, : 85 - 88
  • [7] Adaptive Stochastic Sensor Scheduling for Multi-Channel Radio Environment Mapping
    Crawford, Joseph Ryan
    Paris, Bernd-Peter
    2014 IEEE GLOBAL CONFERENCE ON SIGNAL AND INFORMATION PROCESSING (GLOBALSIP), 2014, : 1204 - 1208
  • [8] Development of a multi-channel, portable optical topography system
    Atsumori, Hirokazu
    Kiguchi, Masashi
    Obata, Akiko
    Sato, Hiroki
    Katura, Takusige
    Utsugi, Kei
    Funane, Tsukasa
    Maki, Atsushi
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 3362 - +
  • [9] The implementation of a multi-channel interferential current electrical stimulation system
    Li, Nan-Chay
    Huang, Ke-Nung
    Jen, Sun-Lon
    Chen, Chun-Jen
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 6207 - 6209
  • [10] Mapping and monitoring of cardioactivity: Multi-channel impedance technology and system
    Schookin, S. I.
    Safonova, L. P.
    Sergeev, I. K.
    Medvedev, O. S.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 264 - 267