Scanning Type Microprobe for Displacement Measurement Based on Standing Wave Detection Using an Optically Trapped Particle

被引:0
|
作者
Takaya Y. [1 ]
Michihata M. [1 ]
Hayashi T. [1 ]
机构
[1] Department of Mechanical Engineering, Graduate School of Engineering, Osaka University, Suita, Osaka 565-0871
关键词
Displacement sensor; Localized interference scale; Microparts; Microprobe; Radiation pressure;
D O I
10.20965/ijat.2011.p0395
中图分类号
学科分类号
摘要
The new scanning type microprobe, based on a standing wave pattern as the interferometric scale and an optically trapped microprobe as the sensing probe to read the scale, is proposed. To confirm the measurement principle the fundamental investigation was conducted experimentally and the properties such as the accuracy, the resolution and the measurable range are evaluated. The feasibility as amicro-displacement sensor is indicated by measurement results of a silicon wafer surface and a silicon sphere. In order to investigate the ability of three-dimensional measurement the scanning measurement of a micro spherical lens with a diameter of 2 mm is carried out.
引用
收藏
页码:395 / 402
页数:7
相关论文
共 44 条
  • [1] Microdisplacement sensor using an optically trapped microprobe based on the interference scale
    Michihata, Masaki
    Hayashi, Terutake
    Nakai, Daisuke
    Takaya, Yasuhiro
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (01):
  • [2] Scanning dimensional measurement using laser-trapped microsphere with optical standing-wave scale
    Michihata, Masaki
    Ueda, Shin-Ichi
    Takahashi, Satoru
    Takamasu, Kiyoshi
    Takaya, Yasuhiro
    OPTICAL ENGINEERING, 2017, 56 (06)
  • [3] Displacement Detection of Optically Trapped Microsphere in Vacuum Based on Kalman Filter
    Jiang Jian-bin
    Hu Hui-zhu
    Li Nan
    Chen Xin-fan
    Shu Xiao-wu
    Liu Cheng
    Fu Zhen-hai
    Gao Xiao-wen
    ACTA PHOTONICA SINICA, 2020, 49 (05)
  • [4] Dimensional measurement of microform with high aspect ratio using an optically controlled particle with standing wave scale sensing
    Takaya, Yasuhiro
    Michihata, Masaki
    Hayashi, Terutake
    Washitani, Taisuke
    CIRP ANNALS-MANUFACTURING TECHNOLOGY, 2012, 61 (01) : 479 - 482
  • [6] Nanometer-displacement detection of optically trapped metallic particles based on critical angle method for small force detection
    Higurashi, Eiji
    Sawada, Renshi
    Ito, Takahiro
    Review of Scientific Instruments, 70 (07): : 3068 - 3073
  • [7] Nanometer-displacement detection of optically trapped metallic particles based on critical angle method for small force detection
    Higurashi, E
    Sawada, R
    Ito, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (07): : 3068 - 3073
  • [8] TISSUE DISPLACEMENT MEASUREMENT USING ULTRASONIC WAVE ADAPTIVE DIGITAL DETECTION METHOD
    OTAKI, H
    YAMAKOSHI, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1995, 34 (5B): : 2835 - 2839
  • [9] Microfluidic Particle Separation and Detection System Based on Standing Surface Acoustic Wave and Lensless Imaging
    Chen, Jin
    Huang, Xiwei
    Xu, Xuefeng
    Wang, Renjie
    Wei, Maoyu
    Han, Wentao
    Cao, Jiafei
    Xuan, Weipeng
    Ge, Yakun
    Wang, Junchao
    Sun, Lingling
    Luo, Ji-Kui
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (07) : 2165 - 2175
  • [10] Six-port type reflectometer based on reflection measurement system using a standing wave detector in the V-band
    Fujiwara, Kohei
    Kouichi, Tokita
    Yakabe, Toshiyuki
    IEICE ELECTRONICS EXPRESS, 2021, 18 (19):