Decision and control of catenary on-line anti-icing current in autotransformer power supply system

被引:0
|
作者
机构
[1] Guo, Lei
[2] Gao, Xiaojie
[3] Li, Qunzhan
来源
Guo, Lei | 1600年 / Science Press卷 / 49期
关键词
Electric network parameters - Electric current collection - Current voltage characteristics - Terminals (electric);
D O I
10.3969/j.issn.0258-2724.2014.06.016
中图分类号
学科分类号
摘要
In order to prevent icing on catenaries and ensure trains' normal operation on electrified railways, a circuit model for the autotransformer (AT) power supply system during anti-icing period was built according to the special structure of long and short loops of the AT power supply system. This model was then used to deduce the comprehensive distribution of the anti-icing current and load current in each AT section, and the current that can prevent icing on the whole line was calculated. After analyzing the relationship between the catenary anti-icing current and the terminal voltage of the power supply arm, the anti-icing current value allowed by the voltage of traction electric network was obtained. On this basis, the decision flow of the on-line anti-icing current was proposed, aiming at maintaining the temperature of contact wire. In addition, simulations were carried out for an AT section, and the simulation results were compared with the measured load data. The results show that the anti-icing current of catenary should be 2 times the critical anti-icing current at least, such that the temperature of contact wire can maintain above 0℃ with anti-icing current. ©, 2014, Science Press. All right reserved.
引用
收藏
相关论文
共 50 条
  • [1] Decision and control of on-line anti-icing current for catenary of electrified railway
    Guo, Lei
    Li, Qun-Zhan
    Gao, Xiao-Jie
    Tiedao Xuebao/Journal of the China Railway Society, 2015, 37 (10): : 42 - 47
  • [2] On-line anti-icing technology for catenary of electrified railway
    Li, Q.-Z. (Lqz3431@263.net), 1600, Science Press (35):
  • [3] Anti-icing measures in the Italian power system
    Quaia, Stefano
    Marchesin, Alessio
    Rampazzo, Davide
    Mancuso, Cristian
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (24) : 5577 - 5585
  • [4] Research on On-line Anti-icing Technology for Carenary along Electrified Railway
    Guo, Lei
    Li, Qunzhan
    ADVANCED RESEARCH ON MATERIAL ENGINEERING AND ELECTRICAL ENGINEERING, 2013, 676 : 321 - 324
  • [5] A method for identifying grounding faults with catenary disconnection in autotransformer power supply system for electric railways
    An, Lin
    Wang, Jun
    Li, Gang
    Li, Hui
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2010, 34 (23): : 92 - 96
  • [6] On-Wing Temperature Estimation and Control for Anti-Icing System on Aircraft
    Gietler, Harald
    Stetco, Christian
    Leitzke, Juliana P.
    Zangl, Hubert
    2019 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2019, : 268 - 273
  • [7] CRONE control based anti-icing/deicing system for wind turbine blades
    Sabatier, J.
    Lanusse, P.
    Feytout, B.
    Gracia, S.
    CONTROL ENGINEERING PRACTICE, 2016, 56 : 200 - 209
  • [8] Anti-Icing Decision Support System Based on a Multi-agent System and Data-Mining
    Martinez Casas, David
    Taboada Gonzalez, Jose Angel
    Arias Rodriguez, Juan Enrique
    Villaroya Fernandez, Sebastian
    INTERNATIONAL SYMPOSIUM ON DISTRIBUTED COMPUTING AND ARTIFICIAL INTELLIGENCE, 2011, 91 : 261 - 264
  • [9] The anti-icing and deicing robot system for electricity transmission line based on external excitation resonant
    Zhou, Feng
    Zhu, Jie
    An, Na
    Wang, Chenguang
    Liu, Jian
    Long, Li
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2020, 15 (04) : 593 - 600
  • [10] Method for on-line detection of leakage current of power supply SPD
    Lu, Qingyong
    Li, Xin
    Xiong, Luhong
    Zeng, Fanqi
    2017 IEEE 5TH INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC-BEIJING), 2017,