Pilot protection of ultra-high voltage transmission lines with negative sequence directional component

被引:0
|
作者
Tianjin University, Tianjin 300072, China [1 ]
机构
来源
Dianli Xitong Zidonghue | 2007年 / 18卷 / 50-53期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] ULTRA-HIGH VOLTAGE OVERHEAD TRANSMISSION LINES
    ALEKSANDROV, GN
    ELECTRICAL TECHNOLOGY RUSSIA, 1971, 1 : 1 - +
  • [2] Impedance-based pilot protection for ultra-high-voltage/extra-high-voltage transmission lines
    Lei, Aoyu
    Dong, Xinzhou
    Shi, Shenxing
    Wang, Bin
    JOURNAL OF ENGINEERING-JOE, 2018, (15): : 904 - 907
  • [3] Pilot Directional Protection Using Negative Sequence Directional Element
    Karady, Geroge G.
    Mandava, Pavanchandra
    2014 CLEMSON UNIVERSITY POWER SYSTEMS CONFERENCE (PSC), 2014,
  • [4] Analysis on Harmonic Transfer along Ultra-High Voltage Transmission Lines
    Liu Shuming
    Zhu Yongqiang
    Xu Yonghai
    Xiao Xiangning
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3287 - 3290
  • [5] Pilot Directional Protection Scheme for LCC-HVDC Transmission Lines Based on the Voltage difference Between Positive and Negative Poles
    Ma, Jing
    Wu, Yuchong
    Liu, Chen
    Cheng, Peng
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (02) : 696 - 709
  • [6] Simulation of lightning current distribution in towers of ultra-high voltage transmission lines
    Li W.
    Xiang C.
    Wen X.
    Dai M.
    Li Z.
    Duan C.
    Wen, Xishan (xswen@whu.edu.cn), 1600, Science Press (42): : 2642 - 2650
  • [7] Optimal control of the voltage and reactive power in ultra-high voltage overhead power transmission lines
    Balametov, AB
    ELECTRICAL TECHNOLOGY RUSSIA, 1998, (03): : 81 - 94
  • [8] Negative-Sequence Pilot Protection With Applications in Open-Phase Transmission Lines
    Wang, Bin
    Dong, Xinzhou
    Bo, Zhiqian
    Klimek, Andrew
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (03) : 1306 - 1313
  • [9] Fast protection of parallel transmission lines on the same tower with same directional negative sequence components
    Xue, Shi-Min
    He, Jia-Li
    Li, Yong-Li
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2008, 41 (08): : 926 - 930
  • [10] Study on setting calculation of distance protection time-delay zones for ultra-high voltage power transmission lines
    Huazhong University of Science and Technology, Wuhan 430074, China
    不详
    Dianli Xitong Zidonghue, 2009, 19 (61-65):