CoWO4/Reduced Graphene Oxide Nanocomposite-Modified Screen-Printed Carbon Electrode for Enhanced Voltammetric Determination of 2,4-Dichlorophenol in Water Samples

被引:1
|
作者
Tajik, Somayeh [1 ]
Beitollahi, Hadi [2 ]
Nejad, Fariba Garkani [2 ]
Zaimbashi, Reza [2 ]
机构
[1] Kerman Univ Med Sci, Res Ctr Trop & Infect Dis, Kerman 7616913555, Iran
[2] Grad Univ Adv Technol, Inst Sci & High Technol & Environm Sci, Environm Dept, Kerman 7631885356, Iran
关键词
water pollution; 2,4-dichlorophenol; phenolic compounds; screen-printed carbon electrode; electrochemical sensor; ELECTROCHEMICAL SENSOR; ASCORBIC-ACID; POLYMER; NANOPARTICLES; TUNGSTATE;
D O I
10.3390/mi15111360
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Water pollution with phenolic compounds is a serious environmental issue that can pose a major threat to the water sources. This pollution can come from various agricultural and industrial activities. Phenolic compounds can have detrimental effects on both human health and the environment. Therefore, it is essential to develop and improve analytical methods for determination of these compounds in the water samples. In this work, the aim was to design and develop an electrochemical sensing platform for the determination of 2,4-dichlorophenol (2,4-DCP) in water samples. In this regard, a nanocomposite consisting of CoWO4 nanoparticles (NPs) anchored on reduced graphene oxide nanosheets (rGO NSs) was prepared through a facile hydrothermal method. The formation of the CoWO4/rGO nanocomposite was confirmed via different characterization techniques. Then, the prepared CoWO4/rGO nanocomposite was used to modify the surface of a screen-printed carbon electrode (SPCE) for enhanced determination of 2,4-DCP. The good electrochemical response of the modified SPCE towards the oxidation of 2,4-DCP was observed by using cyclic voltammetry (CV) due to the good properties of CoWO4 NPs and rGO NSs along with their synergistic effects. Under optimized conditions, the CoWO4/rGO/SPCE sensor demonstrated a broad linear detection range (0.001 to 100.0 mu M) and low limit of detection (LOD) (0.0007 mu M) for 2,4-DCP determination. Also, the sensitivity of CoWO4/rGO/SPCE for detecting 2,4-DCP was 0.3315 mu A/mu M. In addition, the good recoveries for determining spiked 2,4-DCP in the water samples at the surface of CoWO4/rGO/SPCE showed its potential for determination of this compound in real samples.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Graphene-TiO2 Nanocomposite-Modified Screen-Printed Electrode for Sensitive Nitrite Determination in Hot Spring Water
    Li, Xiaobiao
    Hou, Shuxia
    Xie, Chengji
    Fan, Guojing
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (01): : 315 - 323
  • [2] Electrochemical Determination of Clofazimine Using A Carbon Dot Polythionine Nanocomposite-Modified Screen-Printed Electrode
    Fakier-Lesch, Ashiqa
    Ngece-Ajayi, Rachel Fanelwa
    Mohamed, Nuralli
    Cupido, Candice
    ELECTROANALYSIS, 2025, 37 (01)
  • [3] Adsorptive Stripping Voltammetric Determination of 2,4-dichlorophenol by Laponite Modified Carbon Paste Electrode
    Stoytcheva, Margarita
    Zlatev, Roumen
    Velkova, Zdravka
    Gochev, Velizar
    Ayala, Alan
    Montero, Gisela
    Valdez, Benjamin
    ELECTROANALYSIS, 2021, 33 (03) : 695 - 704
  • [4] Development of an Electrochemical Sensor Based on Reduced Graphene Oxide Modified Screen-Printed Carbon Electrode for the Determination of Buprenorphine
    Fakhari, Ali Reza
    Sahragard, Ali
    Ahmar, Hamid
    ELECTROANALYSIS, 2014, 26 (11) : 2474 - 2483
  • [5] Voltammetric Determination of Trace Methyl Parathion using Electrochemically Reduced Graphene Oxide Modified Carbon Screen-Printed Electrodes
    Azimi, Hesameddin
    Sullivan, Connor
    Lu, Dingnan
    Brack, Eric
    Drew, Christopher
    Kurup, Pradeep
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2023, 15 (05): : 356 - 370
  • [6] Glutathione modified screen-printed carbon nanofiber electrode for the voltammetric determination of metal ions in natural samples
    Perez-Rafols, Clara
    Serrano, Nuria
    Manuel Diaz-Cruz, Jose
    Arino, Cristina
    Esteban, Miquel
    TALANTA, 2016, 155 : 8 - 13
  • [7] Reduced Graphene Oxide/Gold Nanoparticles Modified Screen-Printed Electrode for the Determination of Palmitic Acid
    Ching, Chin Boon
    Abdullah, Jaafar
    Yusof, Nor Azah
    JOURNAL OF SENSORS, 2021, 2021
  • [8] CHARACTERIZATION OF CERIUM OXIDE-CHITOSAN NANOCOMPOSITE-MODIFIED SCREEN PRINTED CARBON ELECTRODE AND APPLICATION IN MELATONIN DETERMINATION
    Sunon, Pachanuporn
    Wongkaew, Porntip
    Johns, Jeffrey
    Johns, Nutjaree
    INTERNATIONAL JOURNAL OF GEOMATE, 2018, 14 (42): : 151 - 157
  • [9] Electrochemical Determination of Dextromethorphan on Reduced Graphene Oxide Modified Screen-Printed Electrode after Electromembrane Extraction
    Fakhari, Ali Reza
    Koruni, Mohammad Hossein
    Ahmar, Hamid
    Shahsavani, Abolfath
    Movahed, Siyavash Kazemi
    ELECTROANALYSIS, 2014, 26 (03) : 521 - 529
  • [10] Simultaneous voltammetric determination of droxidopa, acetaminophen, and tyrosine on hematoxylin and graphene oxide/ZnO nanocomposite-modified glassy carbon electrode
    Beitollahi, Hadi
    Salimi, Hadiseh
    Ganjali, Mohammad Reza
    IONICS, 2018, 24 (05) : 1487 - 1495