Deep reinforcement learning control for co-optimizing energy consumption, thermal comfort, and indoor air quality in an office building

被引:1
|
作者
Guo, Fangzhou [1 ]
Ham, Sang woo [1 ]
Kim, Donghun [1 ]
Moon, Hyeun Jun [2 ]
机构
[1] Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
[2] Dankook Univ, Dept Architectural Engn, Yongin, South Korea
关键词
Deep reinforcement learning; Deep deterministic policy gradient; Smart building; Air conditioning; Energy efficiency; Thermal comfort; Indoor air quality; MODELS;
D O I
10.1016/j.apenergy.2024.124467
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With the recent demand for decarbonization and energy efficiency, advanced HVAC control using Deep Reinforcement Learning (DRL) becomes a promising solution. Due to its flexible structures, DRL has been successful in energy reduction for many HVAC systems. However, only a few researches applied DRL agents to manage the entire central HVAC system and control multiple components in both the water loop and the air loop, owing to its complex system structures. Moreover, those researches have not extended their applications by incorporating the indoor air quality, especially both CO2 and PM2.5concentrations, on top of energy saving and thermal comfort, as achieving those objectives simultaneously can cause multiple control conflicts. What's more, DRL agents are usually trained on the simulation environment before deployment, so another challenge is to develop an accurate but relatively simple simulator. Therefore, we propose a DRL algorithm for a central HVAC system to co-optimize energy consumption, thermal comfort, indoor CO2 level, and indoor PM2.5 level in an office building. To train the controller, we also developed a hybrid simulator that decoupled the complex system into multiple simulation models, which are calibrated separately using laboratory test data. The hybrid simulator combined the dynamics of the HVAC system, the building envelope, as well as moisture, CO2, and particulate matter transfer. Three control algorithms (rule-based, MPC, and DRL) are developed, and their performances are evaluated on the hybrid simulator environment with a realistic scenario (i.e., with stochastic noises). The test results showed that, the DRL controller can save 21.4 % of energy compared to a rule-based controller, and has improved thermal comfort, reduced indoor CO2 concentration. The MPC controller showed an 18.6 % energy saving compared to the DRL controller, mainly due to savings from comfort and indoor air quality boundary violations caused by unmeasured disturbances, and it also highlights computational challenges in real-time control due to non-linear optimization. Finally, we provide the practical considerations for designing and implementing the DRL and MPC controllers based on their respective pros and cons.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] RECA: A Multi-Task Deep Reinforcement Learning-Based Recommender System for Co-Optimizing Energy, Comfort and Air Quality in Commercial Buildings
    Xia, Stephen
    Wei, Peter
    Liu, Yanchen
    Sonta, Andrew
    Jiang, Xiaofan
    PROCEEDINGS OF THE 10TH ACM INTERNATIONAL CONFERENCE ON SYSTEMS FOR ENERGY-EFFICIENT BUILDINGS, CITIES, AND TRANSPORTATION, BUILDSYS 2023, 2023, : 99 - 109
  • [2] Energy optimization associated with thermal comfort and indoor air control via a deep reinforcement learning algorithm
    Valladares, William
    Galindo, Marco
    Gutierrez, Jorge
    Wu, Wu-Chieh
    Liao, Kuo-Kai
    Liao, Jen-Chung
    Lu, Kuang-Chin
    Wang, Chi-Chuan
    BUILDING AND ENVIRONMENT, 2019, 155 : 105 - 117
  • [3] Balancing Energy Consumption and Thermal Comfort with Deep Reinforcement Learning
    Cicirelli, Franco
    Guerrieri, Antonio
    Mastroianni, Carlo
    Scarcello, Luigi
    Spezzano, Giandomenico
    Vinci, Andrea
    PROCEEDINGS OF THE 2021 IEEE INTERNATIONAL CONFERENCE ON HUMAN-MACHINE SYSTEMS (ICHMS), 2021, : 295 - 300
  • [4] A multi-task deep reinforcement learning-based recommender system for co-optimizing energy, comfort, and air quality in commercial buildings with humans-in-the-loop
    Xia, Stephen
    Wei, Peter
    Liu, Yanchen
    Sonta, Andrew
    Jiang, Xiaofan
    DATA-CENTRIC ENGINEERING, 2024, 5
  • [5] A review on thermal comfort, indoor air quality and energy consumption in temples
    Yuksel, Ahmet
    Arici, Muslum
    Krajcik, Michal
    Civan, Mihriban
    Karabay, Hasan
    JOURNAL OF BUILDING ENGINEERING, 2021, 35
  • [6] Improving indoor air quality and thermal comfort in office building by using combination filters
    Kabrein, H.
    Yusof, M. Z. M.
    Hariri, A.
    Leman, A. M.
    Afandi, A.
    2ND INTERNATIONAL CONFERENCE ON COMPUTATIONAL FLUID DYNAMICS IN RESEARCH AND INDUSTRY (CFDRI 2017), 2017, 243
  • [7] Energy consumption, indoor thermal comfort and air quality in a commercial office with retrofitted heat, ventilation and air conditioning (HVAC) system
    Che, Wen Wei
    Tso, Chi Yan
    Sun, Li
    Ip, Danny Y. K.
    Lee, Harry
    Chao, Christopher Y. H.
    Lau, Alexis K. H.
    ENERGY AND BUILDINGS, 2019, 201 : 202 - 215
  • [8] Indoor thermal comfort and its effect on building energy consumption
    Yang, Xue-bin
    Sun, De-fa
    Zhou, Xiang-jiang
    Cai, Ling-ling
    Ji, Ying
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING, PTS 1-8, 2011, 71-78 : 3516 - 3519
  • [9] Indoor air quality and thermal comfort evaluation in a Spanish modern low-energy office with thermally activated building systems
    Rey Martinez, Francisco Javier
    Andres Chicote, Manuel
    Villanueva Penalver, Antonio
    Tejero Gonzalez, Ana
    Velasco Gomez, Eloy
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2015, 21 (08) : 1091 - 1099
  • [10] Multitarget control models for building thermal comfort and indoor air quality - A critical review☆
    Li, Yanfei
    Sun, Jian
    Cui, Borui
    Li, Kai
    Dong, Jin
    Lian, Jamie
    Zhao, Xianhui
    Nawaz, Kashif
    RESULTS IN ENGINEERING, 2024, 24