Seismic retrofit of steel-structure school gymnasia with energy dissipation devices and their effects on roof response

被引:0
|
作者
Takeuchi T. [1 ]
Tsutsumi Y. [1 ]
Kumagai T. [1 ]
Ogawa T. [1 ]
机构
[1] Dept. of Arch, Tokyo Institute of Technology
来源
关键词
Elasto-plastic damper; Equivalent linearization; School gymnasium; Seismic retrofit; Viscous damper;
D O I
10.3130/aijs.75.1891
中图分类号
学科分类号
摘要
A number of school gymnasia in Japan built in the 1970s in Japan have exhibited or lead one to foresee insufficient seismic performance, and seismic retrofits on them are still underway throughout the country. However, current assessment practices do not take into account the vertical vibration excitation peculiar to raised roofs, which heavily impacts the collapse of non-structural elements, such as ceiling components or lighting equipment. Energy dissipating retrofits are better suited than common strength-based retrofits to help reduce such excited vibration, however optimum design and evaluation methods remain unclear. This paper looks at the typical school gymnasia in Japan, and investigates retrofit design using elasto-plastie or viscous dampers, discussing its effects on roof response reduction and practical response estimation methods.
引用
收藏
页码:1891 / 1900
页数:9
相关论文
共 50 条
  • [1] Reparability of earthquake-damaged RC frame structure for seismic retrofit with energy dissipation devices
    Zhang, Chao
    Zhou, Yun
    Weng, Dagen
    Wu, Congxiao
    Lu, Dehui
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2014, 47 : 207 - 213
  • [2] Seismic retrofit of an existing building using energy-dissipation devices
    Islam, S
    SEAOC: STRUCTURAL ENGINEERS ASSOCIATION OF CALIFORNIA 70 ANNUAL CONVENTION, PROCEEDINGS, 2001, : 287 - 301
  • [3] Some design issues for building seismic retrofit using energy dissipation devices
    Lee, GC
    Tong, M
    Wu, YH
    PROCEEDINGS OF US-KOREA WORKSHOP ON NEW FRONTIER IN INFRASTRUCTURAL/SEISMIC ENGINEERING, 2000, : 137 - 151
  • [4] SEISMIC RETROFIT OF AN EXISTING HIGH-RISE STEEL MOMENT RESISTING FRAME USING SUPPEMENTAL ENERGY DISSIPATION DEVICES
    Wang, Shanshan
    Mahin, Stephen
    Lai, Jiunwei
    Schoettler, Matthew
    Fundamental Research in Structural Engineering: Retrospective and Prospective, Vols 1 and 2, 2016, : 1111 - 1117
  • [5] Seismic response analysis of structure with energy dissipation devices using force analogy method
    Li, Gang
    Li, Hong-Nan
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2011, 20 (03): : 291 - 313
  • [6] Comparative study on the seismic retrofit of a mid-rise steel building: Steel bracing vs energy dissipation
    TenaColunga, A
    Vergara, A
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1997, 26 (06): : 637 - 655
  • [7] Non-invasive passive energy dissipation systems for the seismic design and retrofit of steel structures
    Christopoulos, C
    Filiatrault, A
    BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2000, : 387 - 394
  • [8] Application of Energy Dissipation Technology to C-category Frame Structure of School Buildings for Seismic Retrofit of Increasing Precautionary Intensity
    Weng, Dagen
    Zhang, Chao
    Lu, Xilin
    ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 : 3480 - 3487
  • [9] Seismic Performance Analysis of Steel Frame With Wedge Devices Based on the Energy Dissipation
    Lei, Jinsong
    Luo, Wenxia
    Jiang, Jialong
    Zhang, Wen
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING IV, 2014, 580-583 : 1624 - +
  • [10] Structural optimization of supporting structure of school gymnasium with steel roof for seismic response reduction of bearing reaction forces
    Kimura T.
    Ohsaki M.
    Sato K.
    1600, Architectural Institute of Japan (85): : 61 - 71