摘要
Reclaimed water poses environmental and human health risks due to residual organic micropollutants and pathogens. Ozonation of reclaimed water to control pathogens and trace organics is an important step in advanced water treatment systems for potable reuse of reclaimed water. Ensuring efficient pathogen reduction while controlling disinfection byproducts remains a significant challenge to implementing ozonation in reclaimed water reuse applications. This study aimed to investigate ozonation conditions using a plug flow reactor (PFR) to achieve effective pathogen removal/inactivation while minimizing bromate and N-Nitrosodimethylamine (NDMA) formation. The pilot scale study was conducted using three doses of ozone (0.7, 1.0 and 1.4 ozone/total organic carbon (O3/TOC) ratio) to determine the disinfection performance using actual reclaimed water. The disinfection efficiency was assessed by measuring total coliforms, Escherichia coli (E. coli), Pepper Mild Mottle Virus (PMMoV), Tomato Brown Rugose Fruit Virus (ToBRFV) and Norovirus (HNoV). The ozone CT values ranged from 1.60 to 13.62 mg min L−1, resulting in significant reductions in pathogens and indicators. Specifically, ozone treatment led to concentration reductions of 2.46–2.89, 2.03–2.18, 0.46–1.63, 2.23–2.64 and > 4 log for total coliforms, E. coli, PMMoV, ToBRFV, and HNoV, respectively. After ozonation, concentrations of bromate and NDMA increased, reaching levels between 2.8 and 12.0 μg L−1, and 28–40.0 ng L−1, respectively, for average feed water bromide levels of 86.7 ± 1.8 μg L−1 and TOC levels of 7.2 ± 0.1 mg L−1. The increases in DBP formation were pronounced with higher ozone dosages, possibly requiring removal/control in subsequent treatment steps in some potable reuse applications. © 2024 Elsevier Ltd
引用
收藏
相关论文
共 50 条
  • [1] A pilot-scale investigation of disinfection by-product precursors and trace organic removal mechanisms in ozone-biologically activated carbon treatment for potable reuse
    Sun, Yewei
    Angelotti, Bob
    Brooks, Matt
    Dowbiggin, Bill
    Evans, Patrick J.
    Devins, Bradford
    Wang, Zhi-Wu
    CHEMOSPHERE, 2018, 210 : 539 - 549
  • [2] Roles of ozone oxidation, adsorption and biodegradation in the removal of disinfection by-product precursors and emerging contaminants in pilot-scale ozone BAC contactors applied for potable reuse
    Sun, Yewei
    Wang, Zhi-Wu
    Angelotti, Bob
    Brooks, Matt
    Dowbiggin, Bill
    Evans, Pat
    Devins, Brad
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 254
  • [3] A pilot-scale study of potable reuse impacts on surface water treatment
    Seshan, Hari
    Adelman, Michael J.
    Russell, Paige J.
    Quicho, Joseph
    Daft, Daniel
    Watson, Thomas
    AWWA WATER SCIENCE, 2024, 6 (06):
  • [4] Removal and growth of microorganisms across treatment and simulated distribution at a pilot-scale direct potable reuse facility
    Miller, Scott E.
    Rodriguez, Roberto A.
    Nelson, Kara L.
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2020, 6 (05) : 1370 - 1387
  • [5] Pilot-scale ozone/biological activated carbon treatment of reverse osmosis concentrate: potential for synergism between nitrate and contaminant removal and potable reuse
    Zhang, Zhong
    King, Jacob F.
    Szczuka, Aleksandra
    Chuang, Yi-Hsueh
    Mitch, William A.
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2020, 6 (05) : 1421 - 1431
  • [6] Pilot-scale electrochemical disinfection of surface water: assessing disinfection by-product and free chlorine formation
    Schaefer, Charles E.
    Lavorgna, Graig M.
    Webster, Todd S.
    Deshusses, Marc A.
    Andaya, Christina
    Urtiaga, Ana
    WATER SCIENCE AND TECHNOLOGY-WATER SUPPLY, 2017, 17 (02): : 526 - 536
  • [7] Optimizing treatment for reduction of disinfection by-product (DBP) formation
    Environmental Engineering Program, American University in Cairo, Cairo 11511, Egypt
    Water Sci. Technol. Water Supply, 2009, 2 (191-198):
  • [8] Removal of emerging waterborne pathogens and pathogen indicators pilot-scale conventional treatment
    Xagoraraki, I. (ixagorar@fac.staff.wisc.edu), 1600, American Water Works Association (96):
  • [9] Removal of emerging waterborne pathogens and pathogen indicators by pilot-scale conventional treatment
    Xagoraraki, I
    Harrington, GW
    Assavasilavasukul, P
    Standridge, JH
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2004, 96 (05): : 102 - 113
  • [10] Optimizing Ozone-Biofiltration Systems for Organic Carbon Removal in Potable Reuse Applications
    Gifford, Mac
    Selvy, Ashley
    Gerrity, Daniel
    OZONE-SCIENCE & ENGINEERING, 2018, 40 (06) : 427 - 440