Accuracy enhancement of metabolic index-based blood glucose estimation with a screening process for low-quality data

被引:0
|
作者
Nakazawa, Tomoya [1 ]
Morishita, Keiji [1 ]
Ienaka, Anna [2 ]
Fujii, Takeo [1 ]
Ito, Masaki [1 ]
Matsushita, Fumie [1 ]
机构
[1] Hamamatsu Photon KK, Electron Tube Div, Shimokanzo, Iwata, Japan
[2] Hamamatsu Photon KK, Intellectual Property Headquarters, Hamamatsu, Japan
关键词
non-invasive blood glucose measurement; near-infrared spectroscopy; accuracy improvement; algorithm; SPECTROSCOPY;
D O I
10.1117/1.JBO.29.10.107001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Significance: Many researchers have proposed various non-invasive glucose monitoring (NIGM) approaches using wearable or portable devices. However, due to the limited capacity of detectors for such compact devices and the movement of the body during measurement, the precision of the acquired data frequently diminishes, which can cause problems during actual use in daily life. In addition, intensive smoothing is often used in post-processing to mitigate the effects of erroneous values. However, this requires a considerable amount of data and results in a delay in the response to the actual blood glucose level (BGL). Aim: Instead of just applying data smoothing in the post-process of the data acquisition, we propose an active low-quality data screening method in the pre-process. In the proposal phase of the screening process, we employ an analytical approach to examine and formulate factors that might affect the BGL estimation accuracy. Approach: A signal quality index inspired by the standard deviation concept is introduced to detect visually apparent noise on signals. Furthermore, the total estimation error in the metabolic index (MI) is calculated based on potential perturbations defined by the signal-to-noise ratio (SNR) and the uncertainty due to discrete sampling. Thereafter, the acquired data were screened by these quality indices. Results: By applying the proposed data screening process to the data obtained from a commercially available smartwatch device in the pre-process, the estimation accuracy of the MI-based BGL was improved significantly. Conclusions: Adopting the proposed screen process improves BGL estimation accuracy in the smartwatch-based prototype. Applying the proposed screen process will facilitate the integration of wearable and continuous BGL monitoring into size- and SNR-limited devices such as smartwatches and smart rings.
引用
收藏
页数:19
相关论文
共 5 条
  • [1] Low-Quality Face Recognition Using an Index-Based Super Resolution Technique
    Tahmasebi, Maryam
    Mohammadi, Shahram
    Hassanpoor, Hossein
    INTERNATIONAL JOURNAL OF PATTERN RECOGNITION AND ARTIFICIAL INTELLIGENCE, 2023, 37 (06)
  • [2] A Learning-based Video Compression on Low-Quality Data by Unscented Kalman Filters with Gaussian Process Regression
    Xiong, Hongkai
    Yuan, Zhe
    Zheng, Yuan F.
    2011 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2011, : 1227 - 1230
  • [3] Signal Quality Index-Based Two-Step Method for Heart Rate Estimation by Combining Electrocardiogram and Arterial Blood Pressure Signals
    Liu, Yulin
    Wei, Shoushui
    Zhang, Shuai
    Liu, Feifei
    Li, Jianqing
    Liu, Chengyu
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (07) : 1502 - 1507
  • [4] Improving the estimation accuracy of alfalfa quality based on UAV hyperspectral imagery by using data enhancement and synergistic band selection strategies
    Fu, Shuai
    Liu, Jie
    Gao, Jinlong
    Feng, Qisheng
    Feng, Senyao
    Miao, Chunli
    Li, Yunhao
    Wu, Caixia
    Liang, Tiangang
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2025, 234
  • [5] High-quality images and data augmentation based on inverse projection transformation significantly improve the estimation accuracy of biomass and leaf area index
    Che, Yingpu
    Wang, Qing
    Xie, Ziwen
    Li, Shilin
    Zhu, Jinyu
    Li, Baoguo
    Ma, Yuntao
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2023, 212