Research on Calculation Method of Containment Spray Coverage Rate Based on Monte Carlo Simulation Method

被引:0
|
作者
Huang J. [1 ]
Wu X. [1 ]
Wen L. [1 ]
Peng Y. [1 ]
机构
[1] State Key Laboratory of Nuclear Power Safety Monitoring Technology and Equipment, China Nuclear Power Design Co., Ltd., Guangdong, Shenzhen
来源
关键词
Containment; Monte Carlo simulation; Spray coverage rate;
D O I
10.13832/j.jnpe.2022.05.0176
中图分类号
学科分类号
摘要
In order to establish a reliable and fast calculation method of containment spray coverage rate, and provide a new auxiliary means for the design and research of the containment spray system, the calculation model of containment spray coverage rate based on Monte Carlo simulation is established in this study by using the method of theoretical analysis. Compared with the calculation results of containment spray coverage rate based on computer aided design (CAD), the applicability of Monte Carlo spray coverage rate calculation method is verified. The results show that the calculation errors of the two methods are within 1%.Therefore, the calculation method of containment spray coverage rate based on Monte Carlo simulation method is reliable and widely applicable. Compared with the spray coverage rate calculation method based on computer aided design (CAD) software, the new method has faster calculation speed and lower human error rate, which is conducive to sensitivity analysis and can greatly improve the design capacity of the containment spray system. © 2022 Yuan Zi Neng Chuban She. All rights reserved.
引用
收藏
页码:176 / 180
页数:4
相关论文
共 8 条
  • [1] 24, 12, pp. 70-73, (2004)
  • [2] 27, 6, pp. 121-126, (2005)
  • [3] 31, 4, pp. 57-60, (2010)
  • [4] pp. 91-95, (2005)
  • [5] 12, 3, pp. 45-49, (2002)
  • [6] 4, 1, pp. 101-103, (2005)
  • [7] 1, 1, pp. 28-40, (1974)
  • [8] DURRETT R., Probability: theory and examples, pp. 76-81, (2010)