Calculation method of the flexural tensile strength of the glass fiber-reinforced polymer stirrup based on the database

被引:0
|
作者
Bai H. [1 ]
Xue W. [1 ]
Jiang J. [1 ]
机构
[1] College of Civil Engineering, Tongji University, Shanghai
关键词
bend radius; calculation method; database; flexural tensile strength of GFRP stirrup; glass fiber-reinforced polymer (GFRP) stirrup; guarantee rate; tensile strength of straight portion; test for the flexural tensile strength of GFRP stirrup;
D O I
10.11990/jheu.202304017
中图分类号
学科分类号
摘要
Tests for the flexural tensile strength of glass fiber-reinforced polymer (GFRP) stirrups mainly concentrate on the impact of the ratio of the bending radius to the diameter on the flexural tensile strength of GFRP stirrups. However, the influence of the tensile strength of the straight portion on the flexural tensile strength of GFRP stirrups has seldom been studied. In this study, three groups (nine specimens in total) with different tensile strengths of the straight portion were examined to investigate the flexural tensile strength of GFRP stirrups using the B. 5 test method from ACI 440. 3R-12. The tensile strengths of the straight portion were 530 MPa for group A, 850 MPa for group B, and 1 100 MPa for group C, and the ratio of the bending radius to the stirrup diameter was 3. The findings revealed that GFRP stirrups ruptured at the bending portion in all specimens. The flexural tensile strengths of the specimens of groups A, B, and C were 325, 445, and 530 MPa, respectively. Moreover, a database was established with 93 systematically collected specimens in the literature at home and abroad and 9 specimens for testing of the flexural tensile strength. A method of calculating the flexural tensile strength of GFRP stirrups with a guaranteed rate of more than 95% was proposed based on the statistical analysis of the database. © 2024 Editorial Board of Journal of Harbin Engineering. All rights reserved.
引用
收藏
页码:223 / 229
页数:6
相关论文
共 33 条
  • [1] XUE Weichen, KANG Qingliang, Application of fiber reinforced plastics in concrete structures, Industrial construction, 29, 2, pp. 19-21, (1999)
  • [2] YE Lieping, FENG Peng, Applications and development of fiber-reinforced polymer in engineering structures, China civil engineering journal, 39, 3, pp. 24-36, (2006)
  • [3] KURTH M C., Zum querkrafttragverhalten von betonbauteilen mit faserverbundkunststoff-bewehrung, pp. 73-87, (2012)
  • [4] AHMED E A., Shear behaviour of concrete beams reinforced with fibre-reinforced polymer (FRP) stirrups, pp. 131-140, (2009)
  • [5] MORPHY R., Behaviour of fibre reinforced polymer (FRP) stirrups as shear reinforcement for concrete structure, pp. 73-97, (1999)
  • [6] IMJAI Thanongsak, Design and analysis of curved FRP composites as shear reinforcement for concrete structures, pp. 76-83, (2007)
  • [7] JOHNSON D., Investigation of glass fibre reinforced polymer reinforcing bars as internal reinforcement for concrete structures, pp. 61-87, (2009)
  • [8] MOHAMED B H M, BENMOKRANE B., Torsion behavior of concrete beams reinforced with glass fiber-reinforced polymer bars and stirrups, ACI structural journal, 112, 5, pp. 543-552, (2015)
  • [9] MOHAMED H M, CHAALLAL O, BENMOKRANE B., Torsional moment capacity and failure mode mechanisms of concrete beams reinforced with carbon FRP bars and stirrups, Journal of composites for construction, 19, 2, (2015)
  • [10] HADHOOD A, GOUDA M G, AGAMY M H, Et al., Torsion in concrete beams reinforced with GFRP spirals, Engineering structures, 206, (2020)