Application of static headspace GC-MS for detection of residual trichloroethylene and toluene solvents in β-cyclodextrin

被引:0
|
作者
Kim, Yu-Kyeong [1 ]
Kwon, Seo-Yeon [1 ]
Seo, Yong-Soo [2 ]
Lee, Yang-Bong [1 ]
Mok, Jin Hong [1 ]
机构
[1] Pukyong Natl Univ, Dept Food Sci & Technol, Busan 48513, South Korea
[2] Pukyong Natl Univ, Cooperat Lab Ctr, Busan 48513, South Korea
关键词
Residual chemicals; beta-Cyclodextrin; Trichloroethylene; Toluene; Static headspace; GC-MS; Food additives; VOLATILE ORGANIC-COMPOUNDS; SOLID-PHASE MICROEXTRACTION; GAS-CHROMATOGRAPHY; FOODS;
D O I
10.1016/j.foodres.2024.115292
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Trichloroethylene (TCE) and toluene (TOL), which have been used for (3-cyclodextrin ((3-CD) synthesis, need to be properly inspected for quality assurance and safety of food additives. In this study, a combination of static headspace separation and gas chromatography-mass spectrometry (SH-GC-MS) was optimized for detecting those residual solvents in (3-CD in the compatible safe and green chemistry. Sample injection amount for SH was determined to 100 mu L with the minimum volume that provides the suitable accuracy. For the safety and accuracy of analysis, equilibrium conditions of solvents were considered and selected to 60 degrees C for 45 min. Also, we found that the addition of salt, like CaCl2, adversely affected recovery efficiency. Under the proposed condition, coefficients of determination (R-2) of both TCE and TOL were more than 0.99 between 0.05-10 mg/L concentrations. Recovery rates and relative standard deviation (RSD) of tested solvents were between 91.7-106.0% and 1.0-8.9%, respectively. From validation with two commercial (3-CDs, both TCE and TOL presented lower than regulatory limits for food additives (1 ppm) with satisfactory RSDs (<20%). Collectively, the proposed analytical methods can contribute to safer, simpler, and greener inspection of residual chemicals present in foods for public health.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Static Headspace GC-MS Detection of Residual Solvents - A Possible Simultaneous Identification and Quantitation Method
    Andrews-Ashley, Alyssa J.
    Belsky, Jennifer L.
    Joyce, Heather R.
    Pan, Chunhua
    Pappa, Horacio
    Wahab, Samir Z.
    LC GC NORTH AMERICA, 2012, 30 (01) : 64 - +
  • [2] Detection of Residual Solvents in Commercial Supplements Using Headspace (HS)-GC-MS
    Takahashi, Mitsuko
    Sugaya, Naeko
    Sakurai, Hikaru
    Sakurai, Katsumi
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2021, 141 (10): : 1205 - 1216
  • [3] Application of static headspace GC-MS for the determination of benzene, toluene, ethylbenzene and xylene in soil and plants
    Gorska, Stanislawa
    Delis, Monika
    Chaber, Paulina
    PRZEMYSL CHEMICZNY, 2012, 91 (04): : 569 - 573
  • [4] FACTORS THAT INFLUENCE THE DETERMINATION OF RESIDUAL SOLVENTS IN PHARMACEUTICALS BY AUTOMATED STATIC HEADSPACE SAMPLING COUPLED TO CAPILLARY GC-MS
    MULLIGAN, KJ
    MCCAULEY, H
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1995, 33 (01) : 49 - 54
  • [5] Determination of Residual Solvents in Linezolid by Static Headspace GC
    Feng, Xiao-Zhen
    Han, Guo-Cheng
    Qin, Jianhe
    Yin, Shi-min
    Chen, Zhencheng
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2016, 54 (04) : 487 - 491
  • [6] Headspace SPME method development for the analysis of volatile polar residual solvents by GC-MS
    Camarasu, CC
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 23 (01) : 197 - 210
  • [7] Gravimetric and Sim-Headspace GC-MS For Residual Organic Solvents Detection in Halal and Wholesomeness Food Analysis
    Yuswan, Mohd Hafis
    Asip, Nurul Najwa
    Mohamad, Haslina
    Jalil, Nurul Hanani A.
    Keso, Shamsidah
    Yusoff, Tengku Shahrul Tengku Md.
    Mohamad, Nurhidayatul Asma
    Ibrahim, Anisah
    Arshad, Syariena
    Song, Lai Kok
    Sani, Muhamad Shirwan Abdullah
    MALAYSIAN APPLIED BIOLOGY, 2024, 53 (03)
  • [8] Application of Static Headspace GC-MS Method for Selective 1,4-Dioxane Detection in Food Additives
    Kim, Myung-Chan
    Park, Su-Yeon
    Kwon, Seo-Yeon
    Kim, Yu-Kyeong
    Kim, Yeong-In
    Seo, Yong-Soo
    Cho, Sueng-Mok
    Shin, Eui-Cheol
    Mok, Jin Hong
    Lee, Yang-Bong
    FOODS, 2023, 12 (17)
  • [9] Detection Limits of EPA Method 8260 with Static and Dynamic Headspace GC-MS Analysis
    Bardsley, Roger
    LC GC NORTH AMERICA, 2009, : 27 - 27
  • [10] Residual solvents analysis in flavors and fragrances, a comparison of headspace vs. liquid injection GC-MS
    Broekhans, Joost
    Leijs, Hans
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245