STUDY OF INFLUENCE OF STRUCTURAL SHAPE ON THERMAL CHARACTERISTICS OF SOLAR CHIMNEY SYSTEMS

被引:0
|
作者
Jia J. [1 ]
Nie J. [1 ,2 ]
Wang J. [1 ]
Su H. [1 ]
Yan S. [1 ,2 ]
Gao H. [1 ,2 ]
机构
[1] College of Energy and Power Engineering, Inner Mongolia University of Technology, Hohhot
[2] Inner Mongolia Key Laboratory of Renewable Energy, Hohhot
来源
关键词
collector efficiency; collector inclination; collector shape; numerical simulation; solar chimney; uncertainty analysis;
D O I
10.19912/j.0254-0096.tynxb.2022-1557
中图分类号
学科分类号
摘要
Different shapes of solar chimney(SC)systems have different effects on the heat collection characteristics of the system. A 10° circular SC numerical simulation model and a test bench were established. The comparision betweenthe numercial simulation and the test results showed that the relative error was less than 4%,which ensured the correctness of the model and numerical simulation method. The same numerical simulation method was used to calculate the 0° circle,0° square and 10° square SC models,and the results of different systems were compared. The results show that the uniformity of the surface temperature field of the absorber varies with different system structures,and the influence of the chimney shadow on the surface temperature field of the 10° square absorber is the least. Compared with the fluid velocity in the chimney,the 10° square has a higher velocity gradient,which is more conducive to determining the turbine position. The total enthalpy difference of the fluid in the chimney of different systems is different,and the total enthalpy difference of the 10° square is larger. Compared with the 0° circular SC system,the collector efficiency of the other three SC systems is increased by 11.328%,43.705% and 66.061%,respectively,and the mass flow rate is increased by 59.36%,8.39% and 39.04%. © 2024 Science Press. All rights reserved.
引用
收藏
页码:1 / 9
页数:8
相关论文
共 16 条
  • [1] HAAF W,, FRIEDRICH K,, MAYR G,, Et al., Solar chimneys part I:principle and construction of the pilot plant in manzanares[J], International journal of solar energy, 2, 1, pp. 3-20, (1983)
  • [2] KIM M H., CFD(computational fluid dynamics)analysis of a solar- chimney power plant with inclined collector roof[J], Energy, 107, pp. 661-667, (2016)
  • [3] CHANDRAMOHAN V P., Computational study on the effect of collector cover inclination angle,absorber plate diameter and chimney height on flow and performance parameters of solar updraft tower(SUT)plant [J], Energy, 172, pp. 366-379, (2019)
  • [4] Optimization of effective parameters on solar updraft tower to achieve potential maximum power output:a sensitivity analysis and numerical simulation[J], Applied energy, 195, pp. 725-737, (2017)
  • [5] NIE J,, TIAN R, CAI Q L,, Et al., Optimal collector angle by test on heat collection performance of solar chimney power plant system[J], Transactions of the Chinese Society of Agricultural Engineering, 34, 12, pp. 224-229, (2018)
  • [6] HUANG M H,, CHEN L, Et al., Experimental and numerical studies for applying hybrid solar chimney and photovoltaic system to the solar-assisted air cleaning system [J], Applied energy, 269, (2020)
  • [7] HOSSEINALIPOUR S M., Performance assessment of solar chimney coupled with earth- to- air heat exchanger:a passive alternative for an indoor swimming pool ventilation in hot- arid climate[J], Applied energy, 299, (2021)
  • [8] THOMAS L., Optimizing collector efficiency of a solar chimney power plant. proceedings of melecon[J], Solar energy, 4, pp. 219-222, (1985)
  • [9] ZUO L, DAI P Z,, LI C,, Et al., Study of the performance for wind supercharged solar chimney power plant affected by the chimney shadow[J], Renewable energy resources, 40, 1, pp. 55-59, (2022)
  • [10] HAAF W., Solar chimneys:part II:preliminary test results from the manzanares pilot plant [J], International journal of sustainable energy, 2, pp. 141-161, (1984)