Numerical Analysis of Flow Characteristics and Energy Dissipation on Flat and Pooled Stepped Spillways

被引:0
|
作者
Farooq, Umar [1 ]
Li, Shicheng [1 ]
Yang, James [1 ,2 ]
机构
[1] KTH Royal Inst Technol, Dept Civil & Architectural Engn, SE-10044 Stockholm, Sweden
[2] Vattenfall AB, R&D, Hydraul Lab, S-81426 Alvkarleby, Sweden
关键词
pooled stepped spillway; depth-averaged flow velocity; realizable k-epsilon model; flow regime; TURBULENCE;
D O I
10.3390/w16182600
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The hydraulic performance of pooled stepped spillways has received less recognition compared to the traditional stepped spillways. Regarding the effectiveness of pooled stepped spillways in managing flow dynamics, previous studies have focused on investigating how different step configurations and varying chute angles can enhance energy dissipation in gravity flow over the chute. However, the potential for optimal performance and the importance of proper design have not been thoroughly explored in the existing literature. This study aims to explore new configurations of pooled stepped spillways and compare them to traditional stepped spillway designs to enhance hydraulic efficiency and maximize energy dissipation. The study examines two types of configurations of stepped spillways-two flat and two pooled configurations, each with ten steps. Using the computational Fluid Dynamics (CFD) technique, such as Volume of Fluid Method (VOF) and the realizable k-epsilon turbulence model for two-phase flow analysis with a 26.6 degrees chute slope. Initially, the model was validated with experimental data by comparing various hydraulic parameters. These parameters include water depth, roller length, jump length, ratio of critical depth, and sequent depth. The hydraulic performance of both stepped geometric configurations was evaluated through numerical simulations to examine how the geometries of flat and pooled stepped spillways influence flow characteristics, energy dissipation, velocity, pressure distribution, and the Froude number at the downstream. The study analyzed downstream flow characteristics, maximum energy dissipation rates, depth-averaged velocity, static pressure, and pressure contours at the lateral direction under six different flow rates in flat and pooled stepped spillways. The findings indicate that flat-step configurations exhibit lower energy dissipation compared to pooled configurations. The relative energy loss of flow on pooled steps dissipates more energy than on flat steps. Furthermore, it is observed that the pooled configurations performed better for energy dissipation and flow stability compared to the flat configurations. The energy dissipation increased in pooled stepped spillways by 34.68% and 25.81%, respectively. Additionally, the depth-averaged flow velocity and pressure distribution decreased in case 2 and case 4 compared to the flat-step configurations.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Numerical Study of Energy Dissipation of Pooled Stepped Spillways
    Morovati, Khosro
    Eghbalzadeh, Afshin
    Soori, Saba
    CIVIL ENGINEERING JOURNAL-TEHRAN, 2016, 2 (05): : 208 - 220
  • [2] Flow aeration, cavity processes and energy dissipation on flat and pooled stepped spillways for embankments
    Guenther, Philipp
    Felder, Stefan
    Chanson, Hubert
    ENVIRONMENTAL FLUID MECHANICS, 2013, 13 (05) : 503 - 525
  • [3] Flow aeration, cavity processes and energy dissipation on flat and pooled stepped spillways for embankments
    Philipp Guenther
    Stefan Felder
    Hubert Chanson
    Environmental Fluid Mechanics, 2013, 13 : 503 - 525
  • [4] A FLOW-3D-Based Numerical Simulation of the Energy Dissipation Characteristics of Pooled Stepped Spillways
    Li, Jing
    Zhou, Yu
    Shu, Zhan
    Mao, Xin
    Xu, Minrong
    Ye, Zhaokai
    Ye, Jun
    2022 8TH INTERNATIONAL CONFERENCE ON HYDRAULIC AND CIVIL ENGINEERING: DEEP SPACE INTELLIGENT DEVELOPMENT AND UTILIZATION FORUM, ICHCE, 2022, : 989 - 994
  • [5] Analysis of Energy Dissipation of Interval-Pooled Stepped Spillways
    Ma, Xin
    Zhang, Jianmin
    Hu, Yaan
    ENTROPY, 2022, 24 (01)
  • [6] Study on Energy Dissipation Characteristics of Skimming Flow on Stepped Spillways
    Ma P.
    Hu Y.
    Liu H.
    Taiwan Water Conservancy, 2021, 69 (02): : 89 - 102
  • [7] Energy dissipation and flow characteristics of baffles and sills on stepped spillways
    Li, Shuai
    Zhang, Jianmin
    Nie, Jing
    Peng, Yong
    JOURNAL OF HYDRAULIC RESEARCH, 2014, 52 (01) : 140 - 142
  • [8] Energy dissipation and flow characteristics of baffles and sills on stepped spillways
    Zare, Hesham K.
    Doering, John C.
    JOURNAL OF HYDRAULIC RESEARCH, 2012, 50 (02) : 192 - 199
  • [9] FLOW AND ENERGY DISSIPATION OVER ON FLAT AND POOLED STEPPED SPILLWAY
    Krisnayanti, Denik Sri
    Suhardjono
    Dermawan, Very
    Sholichin, Mohammad
    JURNAL TEKNOLOGI, 2016, 78 (08): : 79 - 86
  • [10] Study of Flow and Energy Dissipation in Stepped Spillways
    Chafi, C.
    Hazzab, A.
    Seddini, A.
    JORDAN JOURNAL OF CIVIL ENGINEERING, 2010, 4 (01) : 1 - 11