Migration, transformation and removal characteristics of escapted ammonia before wet desulfurization in coal-fired power plants

被引:0
|
作者
Cheng-Qiang, Zheng [1 ,2 ]
Xiao-Long, Li [1 ,2 ]
Guang-Xiang, Liu [1 ,2 ]
Jun-Zhuang, Li [1 ,2 ]
Dao-Bin, Zhou [1 ,2 ]
Jiu-Xiang, Duan [1 ,2 ]
Hao-Liang, Zhang [3 ]
机构
[1] Guoneng Nanjing Electric Power Test and Research Limited, Nanjing,210023, China
[2] China Energy Science and Technology Research Institute Co., Ltd, Nanjing,210023, China
[3] China Energy Longyuan Environmental Engineering Co., Ltd, Beijing,100039, China
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The ammonia composition and emission concentration in the flue gas at denitration outlet, air preheater outlet and dust remover outlet of three ultra-low emission coal-fired units were collected and analyzed by flue gas sampling method of stationary source, indophenol blue spectrophotometry and ion chromatography. Considering the characteristics of units operating conditions and flue gas treatment system, the migration, transtration and removal characteristics of escaped ammonia in air preheater and dust collector were studied. The results showed that the escaped ammonia at denitration outlet of all units was gaseous ammonia under high and low load operating conditions, and the distribution was uneven, with the ammonia emission concentration at typical locations higher than 2.5mg/m3. Gaseous ammonia begined to transform into filtrable ammonia when it flowed through the air preheater along with the flue gas. The filtrable ammonia emitted at the outlet of the air preheater could account for 47.21%∼68.85% of the total ammonia. The temperature drop and flow velocity of flue gas in air preheater affected the generation of filtrable ammonia. The dust collector could remove most of the escaped ammonia, and the removal effect mainly came from the removal of filtrable ammonia. The removal performance of filtrable ammonia varied with dust collector systems. The escaped ammonia in the flue gas of dust remover outlet was mainly in the form of gaseous ammonia, and the concentration was between 0.15 and 0.60mg/m3 © 2024 Chinese Society for Environmental Sciences. All rights reserved.
引用
收藏
页码:58 / 64
相关论文
共 50 条
  • [1] Research progress on migration and transformation characteristics of escaped ammonia in coal-fired power plants
    Zheng C.
    Li X.
    Li J.
    Duan J.
    Yang L.
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2022, 41 (02): : 964 - 973
  • [2] Mercury Removal Characteristics of Coal-Fired Power Plants
    Yang Liguo
    Fan Xiaoxu
    DuanYufeng
    Wang Yunjun
    2013 THIRD INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEM DESIGN AND ENGINEERING APPLICATIONS (ISDEA), 2013, : 930 - 933
  • [3] Study on the Hg emission and migration characteristics in coal-fired power plant of China with an ammonia desulfurization process
    Li, Chunfeng
    Duan, Yufeng
    Tang, Hongjian
    Zhu, Chun
    Li, Ya-ning
    Zheng, Yiwu
    Liu, Meng
    FUEL, 2018, 211 : 621 - 628
  • [4] Discussion on the cause of scaling in wet desulfurization system of large coal-fired power plants
    Deng, Yongqiang
    Zou, Peng
    Wu, Fayuan
    Liu, Ping
    Lin, Fuhai
    2018 FIRST INTERNATIONAL CONFERENCE ON ENVIRONMENT PREVENTION AND POLLUTION CONTROL TECHNOLOGY (EPPCT 2018), 2018, 199
  • [5] Zero Discharge of wastewater Treatment Technology of Wet Desulfurization in Coal-fired Power Plants
    Wang, YunYang
    PROCEEDINGS OF THE 2016 5TH INTERNATIONAL CONFERENCE ON ENVIRONMENT, MATERIALS, CHEMISTRY AND POWER ELECTRONICS, 2016, 84 : 294 - 297
  • [6] Investigation on the ammonia emission characteristics in coal-fired power plants of China
    Zheng, Chengqiang
    Li, Xiaolong
    Li, Junzhuang
    Duan, Jiuxiang
    Wu, Hao
    Zhu, Fahua
    FUEL, 2022, 314
  • [7] Study on characteristics of organic components in condensable particulate matter before and after wet flue gas desulfurization system of coal-fired power plants
    Liu, Siqi
    Wu, Yujia
    Xu, Zhenyao
    Lu, Shengyong
    Li, Xiaodong
    CHEMOSPHERE, 2022, 294
  • [8] Modeling of arsenic migration and emission characteristics in coal-fired power plants
    Zhao, Yan
    Zhang, Cheng
    Ma, Lun
    Yu, Shenghui
    Yuan, Changle
    Li, Junchen
    Tan, Peng
    Fang, Qingyan
    Luo, Guangqian
    Chen, Gang
    JOURNAL OF HAZARDOUS MATERIALS, 2024, 465
  • [9] Effect of wet flue gas desulfurization facilities of coal-fired power plants on mercury emission
    Li Bing
    Wang Hongliang
    Xu Yueyang
    Xue Jianming
    5TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY SYSTEMS ENGINEERING (CPESE 2018), 2019, 156 : 128 - 132
  • [10] THE FATE OF MERCURY IN COAL-FIRED POWER-PLANTS AND THE INFLUENCE OF WET FLUE-GAS DESULFURIZATION
    MEIJ, R