A Microwave System for Measuring Relative Humidity of Hollow Concrete Blocks: A New Proposal and a Sensitivity Analysis

被引:0
|
作者
Sobrinho, Francisco Magno Monteiro [1 ]
Da Silva, Isaac Barros Tavares [2 ]
de Andrade Lira, Ruann Victor [2 ]
de Siqueira Campos, Antonio Luiz Pereira [1 ]
机构
[1] Federal University of Rio Grande do Norte (UFRN), Natal, Brazil
[2] Federal Rural University of the Semi-Arid (UFERSA), Mossoro, Brazil
关键词
Concrete blocks - Frequency selective surfaces - Humidity sensors - Microwave measurement - Microwave sensors;
D O I
10.1590/2179-10742024v23i3286300
中图分类号
学科分类号
摘要
In this article, the authors propose changes to a microwave system for measuring the relative humidity of hollow concrete blocks presented in the literature, aiming to improve the system's sensitivity. The operating frequency range was changed from 2.5 GHz to 5.8 GHz. This reduced the dimensions of the antenna arrays used in the system. Five block samples were used in this work. The frequency selective surface (FSS) used as a sensor has been modified, from a double circular ring to a square loop, which presents a single-band frequency response. The results obtained in this work showed a high correlation between the frequency variation and the relative humidity level. First, second, and third-order functions were compared to see which would better relate resonance frequency to relative humidity. The second-order function presented the best results, considering the Mean Absolute Percentage Error (MAPE), the Mean Square Error (RMS), and the coefficient of determination. We performed a sensor sensitivity analysis showing that the new proposed system is more sensitive than others presented in the literature. © 2024 SBMO/SBMag.
引用
收藏
相关论文
共 50 条
  • [1] A microwave system for measuring moisture of hollow concrete blocks
    Guerra, Juan Rafael Filgueira
    Campos, Antonio Luiz Pereira de Siqueira
    de Andrade, Humberto Dionisio
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 323
  • [2] Microwave system for relative humidity measurement
    Carullo, A.
    Ferrero, A.
    Parvis, M.
    Conference Record - IEEE Instrumentation and Measurement Technology Conference, 1999, 1 : 124 - 129
  • [3] A microwave system for relative humidity measurement
    Carullo, A
    Ferrero, A
    Parvis, M
    IMTC/99: PROCEEDINGS OF THE 16TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS. 1-3, 1999, : 124 - 129
  • [4] Sensitivity of a PMMA polymer capillary microresonator for measuring relative humidity
    Avila Padilla, D. A.
    Torres Moreno, C.
    Cordeiro, Cristiano M. B.
    VIII INTERNATIONAL CONGRESS OF ENGINEERING PHYSICS, 2017, 792
  • [5] New possibilities for measuring the humidity of concrete using cable humidity sensors
    Sakunenko, Yuri
    Betonwerk und Fertigteil-Technik/Concrete Plant and Precast Technology, 2020, 86 (07): : 40 - 47
  • [6] Measurement of relative humidity and temperature in new concrete bridges
    Paroll, H
    MOISTURE MEASUREMENT IN CONCRETE CONSTRUCTIONS EXPOSED TO TEMPERATURE AND MOISTURE VARIATIONS, 1997, 174 : 51 - 65
  • [7] ON-LINE MICROWAVE SYSTEM FOR HUMIDITY MEASURING WITH MICROPROCESSOR
    火真棣
    伏寿春
    JournalofElectronics(China), 1987, (03) : 225 - 233
  • [8] Numerical analysis of thermal transmittance of hollow concrete blocks
    Henrique dos Santos, Gerson
    Fogiatto, Marcelo Adriano
    Mendes, Nathan
    JOURNAL OF BUILDING PHYSICS, 2017, 41 (01) : 7 - 24
  • [9] New ways of measuring and evaluation of humidity of screed and concrete
    Neue Wege der Feuchtemessung und Beurteilung von Estrichen und Betonen
    Rieche, G. (info@prof-rieche.de), 1600, Ernst and Sohn (99):
  • [10] Hollow concrete blocks in New Zealand 1904-10
    Isaacs, Nigel
    CONSTRUCTION HISTORY-INTERNATIONAL JOURNAL OF THE CONSTRUCTION HISTORY SOCIETY, 2015, 30 (01): : 93 - 108