Influence of End Structure on Electromagnetic Forces on End Winding of a 1550 MW Nuclear Generator

被引:2
|
作者
Zeng C. [1 ]
Huang S. [1 ]
Yang Y. [1 ]
Zhou G. [2 ]
机构
[1] Chongqing University, Chongqing
[2] Research and Test Center, Dongfang Electrical Machinery Co. Ltd., Deyang, Sichuan Province
来源
Huang, Song (s.huang@cqu.edu.cn) | 1600年 / Hindawi Limited, 410 Park Avenue, 15th Floor, 287 pmb, New York, NY 10022, United States卷 / 2017期
基金
中国国家自然科学基金;
关键词
Electromagnetic force distribution - Electromagnetic forces - Electromagnetic modeling - End structure - Nuclear generators - Relative length - Structure change - Time step finite element methods;
D O I
10.1155/2017/9545238
中图分类号
学科分类号
摘要
A 3D electromagnetic model of the end region of a 1550 MW nuclear generator is set up. The electromagnetic forces on the involute and nose parts of the end winding under a rated operation are obtained through the 3D time-step finite element method. The electromagnetic forces on different coils in the same phase are analyzed. By changing the rotor's relative length and stator coil's linear length in the 3D electromagnetic model, the electromagnetic force distributions on the end winding are obtained. The influence of each structure change on the electromagnetic force in different directions is studied in detail. Conclusions that can be helpful in decreasing the electromagnetic forces on the end winding through optimizing the end region design are presented. © 2017 Chong Zeng et al.
引用
收藏
相关论文
共 50 条
  • [1] Analysis of electromagnetic forces on involute part of end winding in a 1550 MW nuclear generator
    Zeng Chong
    Huang Song
    Yang Yongming
    2017 IEEE 2ND ADVANCED INFORMATION TECHNOLOGY, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (IAEAC), 2017, : 1 - 4
  • [2] Influence of the end structure on the leakage magnetic field and eddy current loss in a 1 550 MW nuclear generator
    Huang S.
    Zeng C.
    Yang Y.
    Zhou G.
    1600, Chinese Society for Electrical Engineering (36): : 200 - 205
  • [3] Nonlinear electromagnetic vibration of turbo-generator stator end winding
    Hu, YD
    Qiu, JJ
    Ta, N
    ELEVENTH WORLD CONGRESS IN MECHANISM AND MACHINE SCIENCE, VOLS 1-5, PROCEEDINGS, 2004, : 1470 - 1474
  • [4] Influence of constructional turbo-generator end region design on end winding inductances
    Freese, Michael
    Kulig, Stefan
    ARCHIVES OF ELECTRICAL ENGINEERING, 2012, 61 (02) : 199 - 210
  • [5] Calculation of the electromagnetic field and forces in the end region of large generator
    Yao, RP
    Wen, XH
    Li, SF
    APPLIED ELECTROMAGNETICS, 1996, 5 : 128 - 133
  • [6] IMPROVEMENT OF VIBRATION CHARACTERISTICS ON STATOR END WINDING OF 600MW GENERATOR
    Liu, Shi
    Guo, Yongxiong
    Li, Zhi
    Liu, Lei
    Gao, Qingshui
    Feng, Yongxin
    Zhang, Chu
    Yang, Tao
    PROCEEDINGS OF THE ASME POWER CONFERENCE, 2013, VOL 2, 2014,
  • [7] Generator End Winding Vibration Monitoring
    Shally, David
    Farrell, Michael
    Sullivan, Kevin
    2008 PROCEEDINGS OF THE 43RD INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2008, : 299 - 303
  • [8] Monitoring of generator end winding vibrations
    Humer, Matthias
    Vogel, Roman
    Kulig, Stefan
    ICEM: 2008 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES, VOLS 1- 4, 2009, : 1313 - +
  • [9] Electromagnetic vibration of integrity end winding of large turbo-generator stator
    Hu, Yu-Da
    Qiu, Jia-Jun
    Qing, Guang-Hui
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2003, 23 (07): : 93 - 98
  • [10] Influences of Turbo-generator End Winding Dimensions on Electromagnetic Loss in the End Core and Metal Parts.
    Wang, L.
    Li, J.
    Li, W.
    2015 IEEE MAGNETICS CONFERENCE (INTERMAG), 2015,