Measurement and laboratory simulation of site jamming signal in ±800 kV converter station

被引:0
|
作者
Ji, Hongxin [1 ]
Qi, Bo [1 ,2 ]
Zhao, Linjie [3 ]
Zuo, Jian [1 ]
Sun, Xiaqing [3 ]
Li, Chengrong [1 ,2 ]
机构
[1] Beijing Key Laboratory of High Voltage and EMC, North China Electric Power University, Beijing,102206, China
[2] State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing,102206, China
[3] Electric Power Research Institute, China Southern Power Grid, Guangzhou,510080, China
来源
关键词
Partial discharges;
D O I
10.13336/j.1003-6520.hve.2014.12.042
中图分类号
学科分类号
摘要
引用
收藏
页码:3961 / 3971
相关论文
共 35 条
  • [1] Simulation analysis on EMI of +/-800-kV UHVDC converter station
    Yu, Zhanqing
    He, Jinliang
    Zeng, Rong
    Zhang, Bo
    Chen, Shuiming
    Rao, Hong
    Zhao, Jie
    Li, Xiaolin
    Wang, Qi
    2007 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY: WORKSHOP AND TUTORIAL NOTES, VOLS 1-3, 2007, : 1288 - +
  • [2] Measurement and Calculation of Potential Shifting Current in ±800kV HVDC Converter Station
    Wu, Tian
    Liu, Kai
    Liu, Ting
    Xiao, Bin
    Peng, Yong
    Su, Ziming
    Tang, Pan
    Lei, Xinglie
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 1673 - 1678
  • [3] Simulation Analysis on Conducted EMD Caused by Valves in ±800 kv UHVDC Converter Station
    Yu, Zhan-Qing
    He, Jin-Liang
    Zeng, Rong
    Rao, Hong
    Li, Xiao-Lin
    Wang, Qi
    Zhang, Bo
    Chen, Shui-Ming
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2009, 51 (02) : 236 - 244
  • [4] Electromagnetic Interference Prediction of ±800 kV UHVDC Converter Station
    Sun, Haifeng
    Cui, Xiang
    Du, Linsen
    IEEE TRANSACTIONS ON MAGNETICS, 2016, 52 (03)
  • [5] Simulation and Analysis of Operating Overvoltage of AC System at ±800 kV Converter Station Based on EMTS/EMTPE
    Ren, Zheng
    Fan, Jiaqi
    Chen, Xiaolu
    Gao, He
    Lu, Jianqiang
    Zheng, Bowen
    ADVANCES IN ARTIFICIAL SYSTEMS FOR MEDICINE AND EDUCATION II, 2020, 902 : 729 - 737
  • [6] Reliability evaluation for main electrical scheme of a ±800 kV converter station
    Shu, Hongchun
    Hu, Zejiang
    Zhang, Jingfang
    Hu, Cui
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2008, 32 (19): : 35 - 39
  • [7] Measurements of Electromagnetic Interference in An Operating ±800 kV DC Converter Station
    Yu, Zhanqing
    Zhang, Xiao
    He, Jinliang
    Huang, Yin
    Qiu, Wei
    2014 XXXITH URSI GENERAL ASSEMBLY AND SCIENTIFIC SYMPOSIUM (URSI GASS), 2014,
  • [8] Simulation and analysis of resonant overvoltage of ac system at ± 800kV converter station based on EMTS/EMTPE
    Ren Zheng
    Chen Xiaolu
    Gao He
    Zheng Bowen
    Lu Jianqiang
    2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 892 - 896
  • [9] Calculation Methods of Direct Lightning Shielding in ± 800kV Converter Station
    Luo Jianbin
    HaoYanpeng
    Li Licheng
    Liu Qin
    Mao Changgen
    Han Yongxia
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [10] Reliability analysis of electrical system in ±800 kV VSC-DC converter station
    Shu H.
    Dong H.
    Zhao H.
    Xu C.
    Yang Y.
    Zhao X.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2023, 43 (02): : 119 - 126