Influence of orientation of external magnetic field, position and aggregation of magnetic beads on signal of GMR biosensor

被引:0
|
作者
Li F.-Q. [1 ]
Feng J. [1 ]
Chen X. [1 ]
Shi H.-P. [1 ]
机构
[1] Key Laboratory for Thin Film and Microfabrication Technology of the Ministry of Education, Institute of Micro and Nano Science and Technology, Shanghai Jiaotong University
关键词
Biological detection; Giant Magnet Resistance(GMR) biosensor; Magnetic bead; Simulation of magnetic field;
D O I
10.3788/OPE.20101811.2437
中图分类号
学科分类号
摘要
To quantitatively measure the number of magnetic beads and their binding biomolecules by a Giant Magnet Resistance(GMR) biosensor, the influences of the orientation of external magnetic field, the positions and the aggregation of magnetic beads on the biosensor signals should be considered. In this paper, the influences of three kinds of factors are simulated using Comsol software and the simulated results show that the signal amplitudes of the biosensor would be reduced by the tilt of external field, the deviation of bead position from the central area of sensor strips, and the aggregation of beads, especial the tilt of external field. When the tilt is 0.5°, the signal will decrease by 80%. Comparing with the simulated results, a GMR biosensor with the width of 5 μm is fabricated. The dependence of signal outputs on the coverage of magnetic beads is measured and results indicate that it is a linear relation with some deviations. Furthermore, the experimental result is 63 μV when the coverage of magnetic beads is 23.6%, which is smaller than the simulated result in 247 μV. Obtained results prove that both kinds of deviations are owing to the three factors. To measure the magnetic beads quantitatively, it suggests that the measuring conditions should be as fellows: making the external magnetic field perpendicular to the sensor plane; keeping the tilt angle unchanged during the measuring process; putting the magnetic beads to concentrate at the central area of the sensor strips; and avoiding the magnetic bead aggregation.
引用
收藏
页码:2437 / 2442
页数:5
相关论文
共 10 条
  • [1] Megens M., Prins M., Magnetic biochips: a newoption for sensitive diagnostics, Journal of Magnetism and Magnetic Materials, 293, 1, pp. 702-708, (2005)
  • [2] Miller M.M., Sheehan P.E., Edelstein R.L., Et al., A DNA array sensor utilizing magnetic microbeads and magnetoelectronic detection, J. of Mag. and Mag. Mater., 225, 1-2, pp. 138-144, (2001)
  • [3] Rife J.C., Miller M.M., Sheehan P.E., Et al., Design and performance of GMR sensors for the detection of magnetic microbeads in biosensors, Sensors and Actuators A, 107, 3, pp. 209-218, (2003)
  • [4] Baselt D.R., Lee G.U., Natesan M., Et al., A biosensor based on magnetoresistance technology, Biosensors & Bioelectronics, 13, 7-8, pp. 731-739, (1998)
  • [5] Edelstein R.L., Tamanaha C.R., Shee-Han P.E., Et al., The BARC biosensor applied to the detection of biological warfare agents, Biosensors & Bioelectronics, 14, 10-11, pp. 805-813, (2000)
  • [6] Schotter J., Kamp P.B., Becker A., Et al., Comparison of a prototype magnetoresistive biosensor to standard fluorescent DNA detection, Biosensors and Bioelectronics, 19, 10, pp. 1149-1156, (2004)
  • [7] Grahama D.L., Ferreira H.A., Feliciano N., Et al., Magnetic field-assisted DNA hybridisation and simultaneous detection using micron-sized spin-valve sensors and magnetic nanoparticles, Sensors and Actuators B, 107, 2, pp. 936-944, (2005)
  • [8] Ejsing L., Hansen M.F., Menon A.K., Et al., Magnetic microbead detection using the planar Hall effect, Journal of Magnetism and Magnetic Materials, 293, 1, pp. 677-684, (2005)
  • [9] Schepper W., Schotter J., Brckl H., Et al., Analysing a magnetic molecule detection system-computer simulation, Journal of Biotechnology, 112, 1-2, pp. 35-46, (2004)
  • [10] Wang Y.Q., Feng J., Chen X., Et al., Detection of commercial magnetic microbeads with giant magneto resistance sensors, 29, 4, pp. 359-363, (2009)