Thermodynamic analysis on CO2 transcritical two-stage compression refrigerating cycle

被引:0
|
作者
Liu, Jun-Pu [1 ]
Chen, Jiang-Ping [1 ]
Chen, Zhi-Jiu [1 ]
机构
[1] Sch. of Mech. and Power Eng., Shanghai Jiaotong Univ., Shanghai 200030, China
关键词
Carbon dioxide - Computer simulation - Efficiency - Thermodynamics;
D O I
暂无
中图分类号
学科分类号
摘要
This paper analyzed the performance of CO2 transcritical two-stage compression cycle, and contrasted it with one-stage system. The results indicate that the two-stage compression cycle can increase the COP by about 5% compared with the one-stage compression system in the same condition. The optimum heat rejection pressure is 9.0 MP at certain evaporating temperature. The internal heat exchanger can improve the performance greatly below the optimum heat rejection pressure, while little above the optimum heat rejection pressure. The exhaust temperature of the two-stage system is decreased by about 18°C in the same conditions.
引用
收藏
页码:1393 / 1395
相关论文
共 50 条
  • [1] Thermodynamic analysis of CO2 transcritical two-stage compression refrigeration cycle systems with expanders
    Liu S.
    Sun Z.
    Li H.
    Dai B.
    Chen Y.
    Sun, Zhili (sunzhili@tjcu.edu.cn), 1600, Taylor and Francis Asia Pacific (24): : 70 - 77
  • [2] Performance research and theoretical analysis of CO2 transcritical two-stage compression cycle
    Ma, Yi-Tai
    An, Qing-Song
    Wang, Hong-Li
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2009, 42 (11): : 992 - 996
  • [3] Hybrid two-stage CO2 transcritical mechanical compression-ejector cooling cycle: Thermodynamic analysis and optimization
    Ierin, Volodymyr
    Chen, Guangming
    Volovyk, Oleksii
    Shestopalov, Kostyantyn
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 132 : 45 - 55
  • [4] Thermodynamic analysis of a modified transcritical CO2 two-stage compression dual-temperature refrigeration cycle with an ejector
    Wen, Zhidong
    Bai, Tao
    Wan, Jiahao
    APPLIED THERMAL ENGINEERING, 2024, 257
  • [5] Thermodynamic analysis on a two-stage transcritical CO2 heat pump cycle with double ejectors
    Xing, Meibo
    Yu, Jianlin
    Liu, Xiaoqin
    ENERGY CONVERSION AND MANAGEMENT, 2014, 88 : 677 - 683
  • [6] Thermodynamic analysis of a modified two-stage transcritical CO2 refrigeration cycle with an ejector and a subcooler
    Li, Huanmin
    Huang, Qiuyue
    Yu, Jianlin
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 168 : 492 - 505
  • [7] Second law analysis of two-stage compression transcritical CO2 heat pump cycle
    Oezguer, Arif Emre
    Bayrakci, Hilmi Cenk
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2008, 32 (13) : 1202 - 1209
  • [8] Thermodynamic analysis of two-stage transcritical CO2 cycle using flash gas by-pass
    Ozgur, Arif Emre
    Tosun, Cemal
    INTERNATIONAL JOURNAL OF EXERGY, 2015, 16 (02) : 127 - 138
  • [9] Thermodynamic performance and CO2 emission analysis of transcritical CO2 two-stage compression refrigeration system with intermediate gas supplementation
    Wang, Youdong
    Li, Xiaoqiong
    Guo, Yanhua
    Dai, Jian
    Song, Jitian
    He, Qing
    Zhang, Zhentao
    Xu, Qing
    Yang, Junling
    ENERGY, 2025, 320
  • [10] Thermodynamic analysis of CO2 trans-critical two-stage compression refrigeration cycle
    Key Laboratory of Condition Monitoring and Control of Power Plant Equipment, North China Electric Power University, Baoding 071003, China
    Huagong Xuebao, 2008, 12 (2985-2989):