Resolution Enhancement of Total Focusing Imaging Combining with Autoregressive Spectral Extrapolation

被引:0
|
作者
Lin L. [1 ]
Shi S. [1 ]
Sun X. [1 ]
Ma Z. [1 ]
Zhang X. [2 ]
Liu L. [3 ]
Jin S. [1 ]
机构
[1] NDT & E Laboratory, Dalian University of Technology, Dalian
[2] Nuclear Industry Research and Engineering Co., Ltd., Beijing
[3] China Nuclear Industry 23 Construction Co., Ltd., Beijing
关键词
Autoregressive spectrum extrapolation; Imaging resolution; Total focusing method; Ultrasonic detection;
D O I
10.3901/JME.2020.22.008
中图分类号
学科分类号
摘要
The defects with close spacing are difficult to be distinguished by ultrasonic imaging with total focusing method(TFM). Autoregressive spectrum extrapolation with low-order and wide effective frequency band is introduced to compress the pulse width in time domain, achieving subwavelength resolution imaging of TFM. Two preset side-drilled holes having 1.8 mm center distance and 1.3 mm diameter in the simulated model of carbon steel are detected by array probe with 2.25 MHz center frequency and 32 elements. Focusing on full matrix capture, taking 2-order and the width of frequency window represented a 14 dB drop from the maximum amplitude of spectrum, and the autoregressive model is established to extrapolate the high-frequency and low-frequency components beyond effective frequency band. Then, the delay-and-sum algorithm is implemented on the processed full matrix capture data to obtain the TFM image. The simulated results indicated that the combination of TFM and autoregressive spectrum extrapolation with low-order and wide effective frequency band had high robustness and accuracy, so as to effectively separate adjacent defects with center distance of 0.7λ(λ is ultrasonic wavelength). The positioning error is no more than 0.73% while retaining the lateral resolution. Finally, side-drilled holes having 1.8 mm center distance are calculated with the same testing parameters in experiment, and the positioning error is no more than 1.06%, effectively improving imaging resolution of TFM. © 2020 Journal of Mechanical Engineering.
引用
收藏
页码:8 / 13and23
页数:1315
相关论文
共 19 条
  • [1] YAN Rongming, ZHOU Guangping, WAN Gaofeng, Et al., Improvement of ultrasonic testing resolution, Nondestructive Testing, 19, 4, pp. 91-94, (1997)
  • [2] SAFARI A, ZHANG J, VELICHKO A, Et al., Assessment methodology for defect characterisation using ultrasonic arrays, NDT & E International, 94, pp. 126-136, (2018)
  • [3] LIN Li, YANG Pinghua, ZHANG Donghui, Et al., Review of phased array ultrasonic testing for thick wall cast austenitic stainless steel pipeline welds, Journal of Mechanical Engineering, 48, 4, pp. 12-20, (2012)
  • [4] YANG Pinghua, LIN Li, LIU Chunwei, Et al., Experimental measurement and analysis of the lateral resolution of phased array ultrasonic detection, Chinese Journal of Scientific Instrument, 32, 6, pp. 1384-1389, (2011)
  • [5] DRINKWATER B W, WILCOX P D., Ultrasonic arrays for non-destructive evaluation: A review, NDT & E International, 39, 7, pp. 525-541, (2006)
  • [6] HOLMES C, DRINKWATER B W, WILCOX P D., Post-processing of the full matrix of ultrasonic transmit-receive array data for non-destructive evaluation, NDT & E International, 38, 8, pp. 701-711, (2005)
  • [7] YANG Guide, FANG Junchai, ZHAN Hongqing, Et al., Application of full focus technology based on phased array full matrix acquisition, Nondestructive Inspection, 40, 2, pp. 26-27, (2016)
  • [8] LI Yan, Ultrasonic phased array imaging testing by total focusing method, Nondestructive Testing, 39, 5, pp. 57-64, (2017)
  • [9] ZHOU X, PENG J P, LUO L, Et al., Effects of directivity function on total focusing method imaging performance[C/CD], Far East NDT New Technology & Application Forum 2014, (2014)
  • [10] ZHANG J, DRINKWATER B W, WILCOX P D., Ultrasonic array imaging in nondestructive evaluation: Total focusing method with using circular coherence factor, Eighth International Symposium on Precision Engineering Measurement and Instrumentation, (2012)