Optimum insulation thickness for building walls in a hot-dry climate

被引:0
|
作者
Al-Sanea, S.A. [1 ]
Zedan, M.F. [1 ]
机构
[1] Department of Mechanical Engineering, College of Engineering, King Saud University, P.O. Box 800, Riyadh 11421, Saudi Arabia
来源
关键词
Energy utilization - Heat transfer - Optimization - Walls (structural partitions);
D O I
暂无
中图分类号
学科分类号
摘要
The optimum thickness of an insulation layer in a typical building wall is determined under steady periodic conditions using the climatic data of Riyadh. A finite-volume implicit procedure, which has been previously validated, is used to compute the yearly heat transmission loads for various insulation thicknesses. These loads are input to an economic model, based on the present worth method, in order to minimise the total cost of insulation and energy consumption over the lifetime of the building. Cooling and heating loads are integrated separately over the year and treated with different costs in the economic analysis. The wall yearly transmission loads, yearly-averaged dynamic R-value, time lag and decrement factor are presented versus insulation thickness and compared for different wall orientations. A parametric study is performed to establish the sensitivity of the results to changes in economic parameters. The optimum insulation thickness is found to increase with the cost of electricity, building lifetime and inflation rate; and decrease with increasing cost of insulation material, coefficient of performance of air-conditioning equipment and discount rate. The results also show that the wall orientation has a significant effect on the thermal behaviour but a relatively smaller effect on the total cost and consequently the optimum insulation thickness. The south-facing wall is the most favourite orientation since it gives about 12% lower yearly transmission load and 5% lower total cost compared to the least favourite orientation which is the west-facing wall. Among the insulation materials investigated, molded polystyrene is found to be the most economical type with an optimum thickness of 9.3 cm.
引用
收藏
页码:115 / 126
相关论文
共 50 条
  • [1] Determination of optimum insulation thickness based on cooling transmission load for building walls in a hot climate
    Ozel, Meral
    ENERGY CONVERSION AND MANAGEMENT, 2013, 66 : 106 - 114
  • [2] Optimum insulation thickness for external building walls for different climate zone in India
    Shahid, Mohd
    Karimi, Munawar Nawab
    Mishra, Atul Kumar
    JOURNAL OF THERMAL ENGINEERING, 2024, 10 (05): : 1198 - 1211
  • [3] Financially Optimum Insulation Thickness of External Building Walls
    Axaopoulos, Petros J.
    Fylladitakis, Emmanouil D.
    Shabdurakhmanovich, Shaislamov Alisher
    Ogli, Abdullaev Nodirbek Azatvay
    TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY: TMREES19GR, 2019, 2190
  • [4] A study on optimum insulation thickness of building walls in hot summer and warm winter zone in China
    Xu, Chengcheng
    Shao, Suola
    Wei, Wenjian
    Qin, Yanluan
    Li, Nan
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [5] DETERMINATION OF OPTIMUM INSULATION THICKNESS FOR DIFFERENT BUILDING WALLS IN TURKEY
    Fertelli, Ahmet
    TRANSACTIONS OF FAMENA, 2013, 37 (02) : 103 - 113
  • [6] Determination of Environmental Impact and Optimum Thickness of Insulation for Building Walls
    Ucar, Aynur
    Balo, Figen
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2011, 30 (01) : 113 - 122
  • [7] Determination of optimum insulation thickness for building walls with respect to various fuels and climate zones in Turkey
    Bolatturk, A
    APPLIED THERMAL ENGINEERING, 2006, 26 (11-12) : 1301 - 1309
  • [8] Determination of optimum insulation thickness for building walls with moisture transfer in hot summer and cold winter zone of China
    Liu, Xiangwei
    Chen, Youming
    Ge, Hua
    Fazio, Paul
    Chen, Guojie
    Guo, Xingguo
    ENERGY AND BUILDINGS, 2015, 109 : 361 - 368
  • [9] Optimum insulation thickness of walls for energy-saving in hot regions of India
    Sundaram, A. Shanmuga
    Bhaskaran, Anirudh
    INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2014, 33 (01) : 213 - 226
  • [10] Determination of Optimum Insulation Thickness on Different Wall Orientations in a Hot Climate
    Arslan, Erhan
    Karagoz, Irfan
    PROCEEDINGS OF 3RD INTERNATIONAL SUSTAINABLE BUILDINGS SYMPOSIUM (ISBS 2017), VOL 2, 2018, 7 : 145 - 157