Low-cost portable sensor for rapid and sensitive detection of Pb2+ ions using capacitance sensing integrated with microfluidic enrichment

被引:0
|
作者
Amin, Niloufar [1 ]
Chen, Jiangang [2 ]
Cao, Qing [1 ]
Qi, Haochen [1 ,3 ]
Zhang, Jian [3 ]
He, Qiang [4 ]
Wu, Jie Jayne [1 ]
机构
[1] Univ Tennessee, Dept Elect Engn & Comp Sci, Knoxville, TN 37996 USA
[2] Univ Tennessee, Dept Publ Hlth, Knoxville, TN 37996 USA
[3] Wenzhou Univ, Coll Elect & Elect Engn, Wenzhou 325035, Zhejiang, Peoples R China
[4] Univ Tennessee, Dept Environm & Civil Engn, Knoxville, TN 37996 USA
关键词
Capacitive sensing; GSH self-assembled monolayer; AC electrokinetic; On-site detection; Water quality monitoring; Point-of-use testing; METAL; BIOSENSORS;
D O I
10.1007/s00604-024-06798-z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Lead ion (Pb2+) pollution is a critical global issue due to its ability to accumulate in the human body, resulting in severe health problems. Despite extensive research efforts devoted to the detection of Pb2+ contamination, practical, rapid, and field-deployable sensors for Pb2+ is yet to be developed to effectively safeguard the environment and public health. Herein, a label-free affinity-based sensing device is developed based on printed circuit board (PCB) for low-cost, easy-to-use, and real-time on-site detection of Pb2+ ions. The sensors are prepared by forming a self-assembled monolayer of glutathione (GSH) on the surface of gold-plated PCB electrodes, which serves as a molecular probe to recognize Pb2+. Rapid and sensitive detection is achieved by using capacitance sensing integrated with microfluidic enrichment. The sensor's interfacial capacitance is used to indicate specific binding, while the capacitance reading process simultaneously induces alternating current electrothermal (ACET) acceleration of analyte's travel towards the probes. Thus, the enrichment and detection are integrated into a single step, making pre-concentration unnecessary and shortening the assay time to 30 s. This Pb2+ sensor has demonstrated one of the lowest limits of detection reported so far (1.85 fM) with a linear range of 0.01-10 pM. To evaluate the sensor's specificity, non-target metal ions are tested, all showing negligible responses. Testing of tap water sample also yields reasonable results, validating the sensor's robustness. The above-mentioned features, together with a commercial portable readout, make this sensor well-suited for point-of-use Pb2+ detection at low cost.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] A Portable and Power-Free Microfluidic Device for Rapid and Sensitive Lead (Pb2+) Detection
    Fan, Chunhui
    He, Shijiang
    Liu, Gang
    Wang, Lianhui
    Song, Shiping
    SENSORS, 2012, 12 (07) : 9467 - 9475
  • [2] A single-step DNAzyme sensor for ultra-sensitive and rapid detection of Pb2+ ions
    Meng, Jiyu
    Huang, Jiamei
    Oueslati, Rania
    Jiang, Yu
    Chen, Jiangang
    Li, Shanshan
    Dai, Shijie
    He, Qiang
    Wu, Jayne
    ELECTROCHIMICA ACTA, 2021, 368
  • [3] A low-cost microcontrolled photometer with one color recognition sensor for selective detection of Pb2+ using gold nanoparticles
    de Morais, Camilo de L. M.
    Carvalho, Julyana C.
    Sant'Anna, Celso
    Eugenio, Mateus
    Gasparotto, Luiz H. S.
    Lima, Kassio M. G.
    ANALYTICAL METHODS, 2015, 7 (18) : 7917 - 7922
  • [4] Fluorescence and Naked-Eye Detection of Pb2+ in Drinking Water Using a Low-Cost Ionophore Based Sensing Scheme
    Hakonen, Aron
    Stromberg, Niklas
    CHEMOSENSORS, 2018, 6 (04)
  • [5] Removal of lead ions (Pb2+) from water and wastewater: a review on the low-cost adsorbents
    Imran Rahman Chowdhury
    Shakhawat Chowdhury
    Mohammad Abu Jafar Mazumder
    Amir Al-Ahmed
    Applied Water Science, 2022, 12
  • [6] Removal of lead ions (Pb2+) from water and wastewater: a review on the low-cost adsorbents
    Chowdhury, Imran Rahman
    Chowdhury, Shakhawat
    Mazumder, Mohammad Abu Jafar
    Al-Ahmed, Amir
    APPLIED WATER SCIENCE, 2022, 12 (08)
  • [7] A portable and low-cost parallel-plate capacitor sensor for alkali and heavy metal ions detection
    Kholimatussadiah, Septia
    Prijo, Tri Anggono
    JOURNAL OF ADVANCED DIELECTRICS, 2018, 8 (04)
  • [8] A Low-Cost and High Sensitive Paper-Based Microfluidic Device for Rapid Detection of Glucose in Fruit
    Li, Zexian
    Zhu, Yongheng
    Zhang, Weijia
    Xu, Changhua
    Pan, Yingjie
    Zhao, Yong
    FOOD ANALYTICAL METHODS, 2017, 10 (03) : 666 - 674
  • [9] A Low-Cost and High Sensitive Paper-Based Microfluidic Device for Rapid Detection of Glucose in Fruit
    Zexian Li
    Yongheng Zhu
    Weijia Zhang
    Changhua Xu
    Yingjie Pan
    Yong Zhao
    Food Analytical Methods, 2017, 10 : 666 - 674
  • [10] A novel, low-cost microfluidic device with an integrated filter for rapid, ultrasensitive, and high-throughput bioburden detection
    Hasan, Md. Sadique
    Sundberg, Chad
    Tolosa, Michael
    Andara, Abhay
    Ge, Xudong
    Kostov, Yordan
    Rao, Govind
    SCIENTIFIC REPORTS, 2023, 13 (01)