The interference threshold of cardiac pacemakers in electric 50 Hz fields

被引:17
|
作者
Scholten, A. [1 ]
Silny, J. [1 ]
机构
[1] FEMU-RWTH Aachen, Pauwelsstrasse 20, 52074 Aachen, Germany
来源
关键词
Geometry; -; Pacemakers; Plants; (botany);
D O I
10.1080/03091900010025893
中图分类号
学科分类号
摘要
The aim of the study was to determine a 'worst-case' and a 'real-case' interference threshold for implanted cardiac pacemakers (CPM) in electric 50 Hz fields as they appear in high-voltage plants, e.g. beneath high voltage overhead lines. For this purpose the resulting electrical potential distribution within the thorax area of volunteers from an external homogeneous electrical 50 Hz field was measured. Different factors such as different body geometries as well as inspiration and expiration of the lung were considered. Measurements showed that I per 1 kV m -1 unimpaired electrical field strength (RMS) an interference voltage of about 180 μVpp as real-case value and 400 μVpp as worst-case value would occur at the input of a unipolar ventricularly controlled, left pectorally implanted cardiac pacemaker. Therefore, it is possible under worst-case conditions but unlikely under practice-relevant conditions that an implanted cardiac pacemaker is disturbed by present electric 50 Hz fields beneath high voltage overhead lines.
引用
收藏
页码:1 / 11
相关论文
共 50 条
  • [1] The interference threshold of cardiac pacemakers in electric 50 Hz fields
    Scholten, K
    Silny, J
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 2001, 25 (01) : 1 - 11
  • [2] THE EFFECT OF 50-HZ EXTERNAL ELECTRICAL INTERFERENCE ON IMPLANTED CARDIAC-PACEMAKERS
    KAYE, GC
    BUTROUS, GS
    ALLEN, A
    MELDRUM, SJ
    MALE, JC
    CAMM, AJ
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (07): : 999 - 1008
  • [3] The interference threshold of unipolar cardiac pacemakers in extremely low frequency magnetic fields
    Scholten, A
    Silny, J
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 2001, 25 (05) : 185 - 194
  • [4] The interference threshold of unipolar cardiac pacemakers in extremely low frequency magnetic fields
    Scholten, A.
    Silny, J.
    Journal of Medical Engineering and Technology, 2001, 25 (05): : 185 - 194
  • [5] Effects of 50 and 60 Hz, and 20 to 50 kHz magnetic fields on the operation of implanted cardiac pacemakers
    Frank, R
    Souques, M
    Himbert, C
    Hidden-Lucet, F
    Petitot, JC
    Fontaine, G
    Lambrozo, J
    Magne, I
    Bailly, JM
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 2003, 96 : 35 - 41
  • [6] ELECTRIC RAZOR INTERFERENCE WITH CARDIAC PACEMAKERS
    FURMAN, S
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1972, 222 (13): : 1658 - &
  • [7] THE INFLUENCE OF ELEVATED 50 HZ ELECTRIC AND MAGNETIC-FIELDS ON IMPLANTED CARDIAC-PACEMAKERS - THE ROLE OF THE LEAD CONFIGURATION AND PROGRAMMING OF THE SENSITIVITY
    TOIVONEN, L
    VALJUS, J
    HONGISTO, M
    METSO, R
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (12): : 2114 - 2122
  • [8] INFLUENCE OF ELECTRIC 50 HZ FIELDS ON HUMANS
    SCHUY, S
    WAIBEL, R
    ZENTRALBLATT FUR BAKTERIOLOGIE MIKROBIOLOGIE UND HYGIENE SERIE B-UMWELTHYGIENE KRANKENHAUSHYGIENE ARBEITSHYGIENE PRAVENTIVE MEDIZIN, 1979, 169 (3-4): : 366 - 373
  • [9] DETECTION-THRESHOLD OF 50-HZ ELECTRIC-FIELDS BY HUMAN-SUBJECTS
    KATO, M
    OHTA, S
    SHIMIZU, K
    TSUCHIDA, Y
    MATSUMOTO, G
    BIOELECTROMAGNETICS, 1989, 10 (03) : 319 - 327
  • [10] BEDSIDE TEST OF THE EFFECT OF 50HZ ELECTRIC-CURRENT ON THE FUNCTION OF IMPLANTED CARDIAC-PACEMAKERS
    KAYE, GC
    BUTROUS, GS
    NATHAN, AW
    MELDRUM, SJ
    CAMM, AJ
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (03): : 471 - 471