Seismic response control of tall building using semi-active tuned mass damper considering soil-structure interaction

被引:0
|
作者
Wang, Liangkun [1 ,2 ,3 ,4 ]
Zhou, Ying [3 ,4 ]
Zhou, Zhongyi [1 ,2 ]
机构
[1] China Earthquake Adm, Inst Engn Mech, Key Lab Earthquake Engn & Engn Vibrat, Harbin 150086, Peoples R China
[2] Minist Emergency Management, Key Lab Earthquake Disaster Mitigat, Harbin 150086, Peoples R China
[3] Tongji Univ, Dept Disaster Mitigat Struct, Shanghai 200092, Peoples R China
[4] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
Soil-structure interaction; Earthquake mitigation; Semi-active tuned mass damper; Variable mass; Variable damping ratio; IDENTIFICATION; OPTIMIZATION; DESIGN;
D O I
10.1016/j.soildyn.2024.108987
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Soil-structure interaction (SSI) will change structural characteristics of a tall building, while parameters of the passive tuned mass damper (TMD) should be specifically optimized in this case. However, the structural model and soil parameters are full of uncertainties, and the seismic response mitigation of passive TMD suffers from the frequency and damping detuning. To improve its seismic performance, the semi-active TMD (STMD) is presented in this study, which can adjust frequency and damping ratio simultaneously. It can not only add or remove its mass to retune the frequency, but the eddy current damping ratio can also be adjusted in real time by reset the air gap, according to a developed output signals based solely combined algorithm. To verify its seismic mitigation performance preliminarily, a SDOF main structure is investigated, while it is found that when the frequency detuning occurs on the STMD with variable damping solely, a significant performance degradation is detected; while STMD with variable frequency and damping ratio always has the best control performance. Then, a 40story benchmark high-rise building with different SSI types is presented as the case study. Numerical results show that STMD can reduce structural displacement responses effectively and has a better control performance than optimal passive TMD for each model. Meanwhile, frequency detuning of passive TMD is discussed and degradation of robustness is found in the passive TMD with +/- 15 % stiffness detuning. It can be known that proposed STMD has the best control robustness as well, because it is always tuned.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Seismic Response Control of a Nonlinear Tall Building Under Mainshock-Aftershock Sequences Using Semi-Active Tuned Mass Damper
    Wang, Liangkun
    Zhou, Ying
    Shi, Weixing
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2023, 23 (16N18)
  • [2] Semi-active control of seismic response of a building using MR fluid-based tuned mass damper
    Esteki, Kambiz
    Bagchi, Ashutosh
    Sedaghti, Ramin
    SMART STRUCTURES AND SYSTEMS, 2015, 16 (05) : 807 - 833
  • [3] The optimum design of particle tuned mass damper for structural seismic control considering soil-structure interaction
    Liu, Shutong
    Li, Haochen
    Zhang, Fengyu
    Lu, Zheng
    Yang, Shutong
    Li, Peizhen
    JOURNAL OF VIBRATION AND CONTROL, 2024, 30 (7-8) : 1449 - 1463
  • [4] Fuzzy control of asymmetric plan buildings with active tuned mass damper considering soil-structure interaction
    Nazarimofrad, Ebrahim
    Zahrai, Seyed Mehdi
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2018, 115 : 838 - 852
  • [5] Nonlinear seismic fragility assessment of tall buildings equipped with tuned mass damper (TMD) and considering soil-structure interaction effects
    Zhang, Wenyang
    Liu, Shutong
    Shokrabadi, Mehrdad
    Dehghanpoor, Ahmad
    Taciroglu, Ertugrul
    BULLETIN OF EARTHQUAKE ENGINEERING, 2022, 20 (07) : 3469 - 3483
  • [6] Nonlinear seismic fragility assessment of tall buildings equipped with tuned mass damper (TMD) and considering soil-structure interaction effects
    Wenyang Zhang
    Shutong Liu
    Mehrdad Shokrabadi
    Ahmad Dehghanpoor
    Ertugrul Taciroglu
    Bulletin of Earthquake Engineering, 2022, 20 : 3469 - 3483
  • [7] Mitigation of wind response of a tall building using semi-active tuned mass dampers
    Kang, Joowon
    Kim, Hyun-Su
    Lee, Dong-Guen
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2011, 20 (05): : 552 - 565
  • [8] Parameter design and performance evaluation of tuned mass damper (TMD) for seismic control of structure considering soil-structure interaction (SSI)
    Gao, Zhidong
    Zhao, Mi
    Wu, Yangzhou
    Wang, Meng
    Du, Xiuli
    STRUCTURES, 2023, 52 : 1116 - 1129
  • [9] SEISMIC RESPONSE CONTROLLED STRUCTURE DAMPER WITH SEMI-ACTIVE MASS-DAMPER
    Yang, Fan
    Sedaghati, Ramin
    Esmailzadeh, Ebrahim
    IMECE 2008: PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 5, 2009, : 169 - 175
  • [10] Experimental verification of seismic vibration control using a semi-active friction tuned mass damper
    Lin, Ging-Long
    Lin, Chi-Chang
    Lu, Lyan-Ywan
    Ho, Yu-Bo
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2012, 41 (04): : 813 - 830