Filtered back-projection image reconstruction algorithm for opposite parallel linear CT scanning

被引:0
|
作者
Wu W. [1 ,2 ]
Quan C. [1 ]
Liu F. [1 ,2 ]
机构
[1] Key Laboratory of Optoelectronic Technology and Systems of the Ministry of Education, Chongqing University, Chongqing
[2] Engineering Research Center of Industrial Computed Tomography Nondestructive Testing of the Ministry of Education, Chongqing University, Chongqing
来源
Guangxue Xuebao/Acta Optica Sinica | 2016年 / 36卷 / 09期
关键词
Computed tomography; Filtered back-projection; Image reconstruction; Imaging systems; Limited angle; Opposite parallel linear scanning;
D O I
10.3788/AOS201636.0911009
中图分类号
学科分类号
摘要
The computed tomography setup for the opposite parallel linear scanning (OPLCT) of X-ray source and detectors is simple in structure and feasible to achieve portability or mobility. The order subset-simultaneous algebraic reconstruction algorithm has been used in the preliminary studies, but its image reconstruction time is too long to realize fast imaging. To address this problem, we proposed a filtered back-projection algorithm for OPLCT (OPLFBP) based on the Fourier's theorem. A single translation (1T) model was constructed for image reconstruction, while this model results in limited angle problem and cannot completely reconstruct the object image using the OPLFBP algorithm. Further, a multiple translation (MT) model was proposed, and meanwhile, models for two orthogonal translations (2T) and three symmetrical translations (3T) were constructed respectively. The simulation results for the 1T, 2T and 3T modes show that the OPLFBP algorithm is effective, and the 2T and 3T scanning modes and the traditional circular scanning mode are comparable in terms of reconstrution time and image quality. © 2016, Chinese Lasers Press. All right reserved.
引用
收藏
页数:11
相关论文
共 17 条
  • [1] Fuchs V.R., Sox H.C., Physicians' views of the relative importance of thirty medical innovations, Health Affairs, 20, 5, pp. 30-42, (2001)
  • [2] Wang G., Liu F., Liu F.L., Et al., Top-level design of the first CT-MRI scanner, 12th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, pp. 975-978, (2013)
  • [3] Liu F.L., Yu H.Y., Cong W.X., Et al., Top-level design and pilot analysis of low-end CT scanners based on linear scanning for developing countries, Journal of X-Ray Science and Technology, 22, 5, pp. 673-686, (2014)
  • [4] Wang J., Liu F., Zou Y., Electronic linear scanning micro-nano focus CT scanning system and method
  • [5] Smith B.D., Singh T., Fan-beam reconstruction from a straight line of source points, IEEE Transactions on Medical Imaging, 12, 1, pp. 10-18, (1993)
  • [6] Sidky E.Y., Zou Y., Pan X.C., Volume image reconstruction from a straight-line source trajectory, IEEE Nuclear Science Symposium Conference Record, 5, pp. 2441-2444, (2005)
  • [7] Gao H.W., Zhang L., Xing Y., Et al., Volumetric imaging from a multi-segments straight-line trajectory and a practical reconstruction algorithm, Optical Engineering, 46, 7, (2007)
  • [8] Gao H.W., Zhang L., Chen Z.Q., Et al., Direct filtered-backprojection-type reconstruction from a straight-line trajectory, Optical Engineering, 46, 5, (2006)
  • [9] Gao H.W., Zhang L., Chen Z.Q., Et al., Straight-line-trajectory-based X-ray tomographic imaging for security inspections: System design, image reconstruction and preliminary results, IEEE Transactions on Nuclear Science, 60, 5, pp. 3955-3968, (2013)
  • [10] Liu B., Zeng L., Parallel SART algorithm of linear scan cone-beam CT for fixed pipeline, Journal of X-Ray Science and Technology, 17, 3, pp. 221-232, (2009)