Performance analysis and experimental study on high temperature traveling crane air-conditioners based on system simulation

被引:0
|
作者
Wang, Tao
Wu, Zhi-Min
Liu, Ying
Wang, Dan
机构
[1] College of Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
[2] Shanghai Hanyao Industrial Ltd, Shanghai 200949, China
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Theoretical calculation was integrated with experimental verification to study the running performance of traveling crane air-conditioners, and the method of system simulation was applied to the developing process of products. The simulation models of the system and the components were established and the system equilibrium point was given by numerical calculation. The mathematical model was revised by comparing the simulating curves with test results. The changes of dynamic performance of prototypes affected by working conditions were analyzed with both simulation and test results. The conclusion is that the refrigeration capacity and the outlet temperature of compressor fluctuate obviously during the dynamic process. Some effective measures should be taken to reduce the outlet temperature of compressor, which can improve the whole performance.
引用
收藏
页码:321 / 324
相关论文
共 50 条
  • [1] SIMULATION BASED EVALUATION OF CONTROL OF RESIDENTIAL AIR-CONDITIONERS
    MYERS, AK
    PAHWA, A
    SHULTIS, JK
    ELECTRIC POWER SYSTEMS RESEARCH, 1990, 19 (01) : 37 - 46
  • [2] Experiments for actual performance evaluation of room air-conditioners in an experimental house: Research on performance evaluation of room air-conditioners part 1
    Sumiyoshi, Daisuke
    Ogino, Takashi
    Miura, Hisashi
    Hosoi, Akinori
    Sawachi, Takao
    Journal of Environmental Engineering (Japan), 2013, 78 (688): : 497 - 505
  • [3] EXPERIMENTAL STUDY OF R290 ENHANCED SYSTEM PERFORMANCE IN RESIDENTIAL AIR-CONDITIONERS AND HEAT PUMPS
    Xu, B.
    Chen, J. P.
    Qi, Z. G.
    Li, F.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 1576 - +
  • [4] Analysis of barriers for using residential air-conditioners based on questionnaire survey
    Socio-economic Research Center, Central Resarch Institute of Electric Power Industry, Japan
    不详
    不详
    J. Environ. Eng., 652 (517-526):
  • [5] A microcontroller-based soft-starter for residential air-conditioners: harmonic analysis
    El Ferik, S.
    Ahmed, C. B.
    Amor, L. Ben
    Hussain, S. A.
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2008, 27 (05) : 1081 - 1097
  • [6] Experimental performance of R432A to replace R22 in residential air-conditioners and heat pumps
    Park, Ki-Jung
    Shim, Yun-Bo
    Jung, Dongsoo
    APPLIED THERMAL ENGINEERING, 2009, 29 (2-3) : 597 - 600
  • [7] A Study of Effects of Surrounding Structures towards Airflow Performance in the Outdoor Unit of Split-type Air-conditioners
    Wei, Eric Phan Tze
    Shukor, Mohd Hamdi Abdul
    RECENT ADVANCES IN FLUID MECHANICS, 2009, : 15 - 21
  • [8] Weather sensitivity of physically based model of residential air-conditioners for direct load control:: A case study
    El-Férik, S
    Hussain, SA
    Al-Sunni, FM
    PROCEEDINGS OF THE IASTED INTERNATIONAL CONFERENCE ON APPLIED SIMULATION AND MODELLING, 2004, : 189 - 194
  • [9] Effect of reduced evaporator airflow on the high temperature performance of air conditioners
    DuPont Energy Engineering, Wilmington, United States
    Energy Build, 3 (195-201):
  • [10] Effect of reduced evaporator airflow on the high temperature performance of air conditioners
    Rodriguez, AG
    ONeal, D
    Davis, M
    Kondepudi, S