Effect of atmospheric factors on AC corona inception voltage of conductors and its correction

被引:0
|
作者
Hu, Qin [1 ]
Shu, Lichun [1 ]
Jiang, Xingliang [1 ]
Sun, Caixin [1 ]
Yuan, Qianfei [1 ]
Yang, Zhangang [1 ]
机构
[1] State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Shapingba District, Chongqing 400044, China
来源
关键词
Electric corona - Atmospheric pressure - Pressure effects - Atmospheric temperature;
D O I
暂无
中图分类号
学科分类号
摘要
Variation of air temperature, pressure and humidity along the line corridor in high altitude area will affect the corona characteristics of conductors. However, the research on comprehensive effects of these atmospheric factors is rare. Therefore, AC corona discharge experiments on four kinds of smooth conductors with different diameter are performed in large-scale artificial climate chamber where air temperature, pressure and humidity can be adjusted. Experimental results indicate that the effect of variation of air temperature on corona inception voltage is not obvious when air pressure and absolute humidity keep constant. With the increase of absolute humidity, the effect of air pressure on corona inception voltage will reduce, shows such feasturs that in region of low humidity, corona inception voltage increases slowly with the increase of absolute humidity, and good accordance is achieved between the measured and calculated results, while in region of high humidity, corona inception voltage decreases, and the difference between the measured and calculated results is big due to condensation on conductor, which distorts the surface electric field of conductors. Besides, The calculation formula and predicting method for corona inception voltage are presented, with conductor diameter, air pressure and humidity considered.
引用
收藏
页码:70 / 76
相关论文
共 50 条
  • [1] DC positive corona inception performances of stranded conductors and its affecting factors
    State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Shapingba District, Chongqing 400044, China
    Zhongguo Dianji Gongcheng Xuebao, 2009, 34 (108-114): : 108 - 114
  • [2] Numerical Model of Negative DC Corona Inception Voltage of Stranded Conductors
    Meng, Xiaobo
    Wang, Liming
    Zhang, Ruobing
    Chen, Fenglin
    Zhang, Lin
    Guan, Zhicheng
    Yang, Yingjian
    2011 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS 1 AND 2, 2011, : 361 - 364
  • [3] Analysis on altitude correction factor of corona inception voltage/electric field of AC transmission lines using the mobile corona cage
    Chen, Yong
    Xie, Xiong-Jie
    Bian, Xing-Ming
    Liu, Yun-Peng
    Zhou, Wen-Jun
    Wang, Li-Ming
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (06): : 1385 - 1391
  • [4] Influence of Air Pressure on Positive DC Corona Inception Voltage of Stranded Conductors in the Corona cage
    Meng, Xiaobo
    Bian, Xingming
    Chen, Fenglin
    Yang, Yingjian
    Wang, Liming
    Guan, Zhicheng
    2010 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTIC PHENOMENA, 2010,
  • [5] CALCULATION OF AC CORONA INCEPTION VOLTAGE IN NONUNIFORM AIR GAP FIELDS
    YANABU, S
    KAWAGUCH.Y
    ELECTRICAL ENGINEERING IN JAPAN, 1971, 91 (04) : 209 - &
  • [6] Corona Onset Voltage Gradient of Bundle Conductors for EHV/UHV AC Power Lines in Corona Cages Considering Altitude Correction
    Huang, Shilong
    Liu, Yunpeng
    Chen, Shaoshuai
    Liu, Daran
    He, Wangling
    Wan, Baoquan
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2020, 6 (03): : 693 - 703
  • [7] Calculation of the Corona Onset Voltage Gradient under Variable Atmospheric Correction Factors
    Carsimamovic, A.
    Mujezinovic, A.
    Carsimamovic, S.
    Bajramovic, Z.
    Kosarac, M.
    Stankovic, K.
    IEEE EUROCON 2015 - INTERNATIONAL CONFERENCE ON COMPUTER AS A TOOL (EUROCON), 2015, : 554 - 558
  • [8] Corona inception field of typical overhead line conductors under variable atmospheric conditions
    Bousiou, Evanthia, I
    Mikropoulos, Pantelis N.
    Zagkanas, Vasileios N.
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 178
  • [9] A new method for calculation of corona inception voltage in stranded conductors of overhead transmission lines
    Zangeneh, Ali
    Gholami, Ahmad
    Zamani, Vahraz
    FIRST INTERNATIONAL POWER & ENERGY CONFERENCE (PECON 2006), PROCEEDINGS, 2006, : 571 - 574
  • [10] The Impact of Water Droplet Vibration on Corona Inception on Conductors Under 50 Hz AC Fields
    Li, Qi
    Rowland, Simon M.
    Dupere, Iain
    Morris, Richard S.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (05) : 2428 - 2436