Calculation method of lightning trip-out rate of transmission line under jet stream arc-extinguishing condition

被引:0
|
作者
Wang, Jufeng [1 ]
Liu, Jinlian [1 ]
Wu, Guoqiang [1 ]
Liu, Qiliang [1 ]
Guo, Wei [1 ]
机构
[1] College of Electrical Engineering, Guangxi University, Nanning,530004, China
来源
Gaodianya Jishu/High Voltage Engineering | 2015年 / 41卷 / 03期
关键词
Drops;
D O I
10.13336/j.1003-6520.hve.2015.03.019
中图分类号
X9 [安全科学];
学科分类号
0837 ;
摘要
Jet stream arc-extinguishing lightning protection gap (JSALPG) is an initiative arc-extinguishing lightning protection method aiming at suppressing insulator arc-establishing. In order to calculate the lightning trip-out rate under jet stream arc-extinguishing (JSA) condition, firstly, we acquired an approximate ideal arc-establishing coefficient (about 0.02) and the arc-establishing rate formula under JSA condition by experimental statistics and probability analysis. Secondly, we established the calculation models of lightning trip-out rate under JSA condition by using the regulations method. Finally, we selected a typical example of 35 kV line for verification. The theoretical calculation results show that the annual average lightning trip-out rate at plain and mountainous area of this line have dropped to 0.380 8 and 0.384 2 times/(100 km·a), respectively, and the drop ratios are 95.53% and 96.06% respectively. The practical operation results show that the above two factors have dropped to 0.530 3 and 0.564 1 times/ (100 km·a), respectively and the drop ratios are 93.78% and 94.21%, respectively. The results above preliminarily verify that the validation of theoretical calculation method and the operation effect of JSALPG. ©, 2015, Gaodianya Jishu/High Voltage Engineering. All right reserved.
引用
收藏
页码:840 / 847
相关论文
共 19 条
  • [1] Research on the effect of the Arc Extinguishing Time of Lightning Protection Parallel Gap on Lightning Trip-out Rate
    Wang, Jufeng
    Guo, Wei
    Wu, Dong
    Li, Guodong
    Liang, Xue
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 65 - 69
  • [2] New Division Method on Lightning Scope and Lightning Trip-out Rate Calculation for Catenary
    Li, Ruifang
    Wu, Guangning
    Cao, Xiaobin
    Ma, Yutang
    Wu, Jingwen
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [3] Calculation method on lightning trip-out rate of transmission lines considering the influence of power frequency voltage
    Liu, Gang
    Xu, Bin
    Wang, Xiaomin
    Chen, Xiyang
    Gaodianya Jishu/High Voltage Engineering, 2013, 39 (06): : 1481 - 1487
  • [5] Mechanism on novel jet stream arc-extinguishing lightning protection gap based on suppressing arc-establishing rate
    Wang, Jufeng
    Liu, Jinlian
    Liu, Qiliang
    Wu, Guoqiang
    Guo, Wei
    Gaodianya Jishu/High Voltage Engineering, 2014, 40 (09): : 2862 - 2870
  • [6] Study of Lightning Stroke Trip-out Fault Analysis for Transmission Line
    Li, Xiaolan
    Chen, Jiahong
    Gu, Shanqiang
    2016 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2016, : 2296 - 2300
  • [7] Calculation of the transmission line shielding failure trip-out rate by utilized terrain parameters
    Cao, Xiao-Bin
    Ma, Yu-Tang
    Wu, Guang-Ning
    Li, Rui-Fang
    Su, Jie
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (05): : 1178 - 1183
  • [8] Calculation of Lightning Trip-out Rates for 10 kV Overhead Distribution Line
    Lu Zejun
    Gu Shanqiang
    Zhao Chun
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 667 - 670
  • [9] Study on the Causes and Countermeasures of High Lightning Trip-Out Rate on Electric Transmission Lines
    Bi, Jieting
    Wang, Jufeng
    ENERGIES, 2025, 18 (04)
  • [10] Lightning Trip-Out Risk Evaluation of a 220kV Transmission Line in Shiyan
    Sun Tao
    Liu Hua
    Qi Yulong
    Li Han
    Zhou Wenjun
    Yu Jianhui
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 1508 - 1511