Influence of Parameters of Digital Signal Generator on Measurement Results of Soil Conductivity Meter

被引:0
|
作者
Wang, Dong [1 ]
Yang, Wei [1 ]
Meng, Chao [1 ]
Ren, Xinjian [1 ]
Li, Minzan [1 ]
机构
[1] Key Laboratory of Modern Precision Agriculture System Integration Research, Ministry of Education, China Agricultural University, Beijing,100083, China
关键词
Soils;
D O I
暂无
中图分类号
TU4 [土力学、地基基础工程];
学科分类号
081401 ;
摘要
For the vehicle-mounted soil conductivity measurement system based on the current-voltage four-terminal method, the excitation source will fluctuate with the change of soil load, thereby affecting the measurement results. Using waveform standard and strong anti-interference ability adjustable frequency and amplitude modulation digital signal generator instead of ordinary excitation source, by exploring the influence of different frequencies and amplitudes of the signal generator on the experimental results, and then the most suitable frequency and amplitude were fond for the vehicle-mounted measurement system value. In order to reduce the impact of complex environment of field on the experimental results, the experiment was divided into laboratory exploratory experiments and field confirmatory experiments. Laboratory exploratory experiments set five amplitudes and 20 frequencies for experiments. By analyzing 6 000 sets of laboratory data of 60 sets of samples, it can be known that the larger the amplitude at the same frequency was, the better the experimental effect was, and the best amplitude was 10 V. Under the same amplitude, with the increase of frequency, the soil conductivity showed a parabolic trend which was increased first and then decreased. The measured value of the soil conductivity and the reference value determination coefficient R2 reached 0.950 5 at the amplitude of 10 V and frequency of 100 Hz, and the experimental effect was the best. The best amplitude of the field confirmatory experiment was still 10 V, but because the soil load was increased with the increase of the electrode spacing, the best frequency of the field confirmatory experiment became 1 kHz, with an amplitude of 10 V and a frequency of 1 kHz. The measured value of conductivity and the reference value R2 were 0.848 4, which was the best experimental effect. © 2021, Chinese Society of Agricultural Machinery. All right reserved.
引用
收藏
页码:336 / 343
相关论文
共 50 条
  • [1] Influence of Selected Parameters on Radiant Intensity Measurement Results - Light Meter and a CCD Camera Comparison
    Parzych, Joanna
    INTERNATIONAL JOURNAL OF ELECTRONICS AND TELECOMMUNICATIONS, 2018, 64 (04) : 451 - 456
  • [2] The Influence of the Generator Signal Parameters Over the AntiBubbles Formation
    Adochiei, Felix-Constantin
    Seritan, George-Calin
    Enache, Bogdan-Adrian
    Argatu, Florin-Ciprian
    Dobre, Andreea Roxanda
    2020 INTERNATIONAL SYMPOSIUM ON FUNDAMENTALS OF ELECTRICAL ENGINEERING (ISFEE), 2020,
  • [3] Influence of water temperature on results of current meter calibration and measurement
    Mattas, Daniel
    Ramesova, Libuse
    JOURNAL OF HYDROLOGY AND HYDROMECHANICS, 2013, 61 (03) : 208 - 213
  • [4] A new laser scanning meter measurement approach using digital signal processing
    Shyu, LH
    Fu, YF
    Shieh, JY
    PROCEEDINGS OF THE FIRST INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, 1999, : 483 - 488
  • [5] Influence of Measurement Parameters Settings on the Results of the CT Measurement
    Kowaluk, Tomasz
    Wozniak, Adam
    MECHATRONICS 2017: RECENT TECHNOLOGICAL AND SCIENTIFIC ADVANCES, 2018, 644 : 607 - 612
  • [6] Digital interface device for field soil hydraulic conductivity measurement
    Cernicchiaro, G.
    Barmak, R.
    Teixeira, W. G.
    JOURNAL OF HYDROLOGY, 2019, 576 : 58 - 64
  • [7] The Influence of Digital Signal Processing on Electronic Measurement and Instrument
    Lv Yuliang
    AGRO FOOD INDUSTRY HI-TECH, 2017, 28 (03): : 1861 - 1865
  • [8] Application of methods of digital spectral estimation in the measurement of the parameters of a signal
    B. V. Tsypin
    M. G. Myasnikova
    V. V. Kozlov
    S. V. Ionov
    Measurement Techniques, 2011, 53 : 1118 - 1124
  • [9] APPLICATION OF METHODS OF DIGITAL SPECTRAL ESTIMATION IN THE MEASUREMENT OF THE PARAMETERS OF A SIGNAL
    Tsypin, B. V.
    Myasnikova, M. G.
    Kozlov, V. V.
    Ionov, S. V.
    MEASUREMENT TECHNIQUES, 2011, 53 (10) : 1118 - 1124
  • [10] Measurement of soil electrical conductivity based on direct digital synthesizer (DDS) and digital oscilloscope
    Pei, Xiaoshuai
    Meng, Chao
    Li, Minzan
    Yang, Wei
    Zhou, Peng
    INTERNATIONAL JOURNAL OF AGRICULTURAL AND BIOLOGICAL ENGINEERING, 2019, 12 (06) : 162 - 168