Influencing factors on infiltration rate of heating rooms in hot summer and cold winter zone

被引:1
|
作者
Ge J. [1 ]
Wang D.-H. [1 ]
Zhao K. [1 ]
机构
[1] College of Civil Engineering and Architecture, Zhejiang University, Hangzhou
关键词
Air infiltration rate; Hot summer and cold winter zone; Radiant floor heating; Tracer gas method; Warm-air heating;
D O I
10.3785/j.issn.1008-973X.2019.07.022
中图分类号
学科分类号
摘要
The flow rate of air infiltration and corresponding influencing factors were measured and analyzed. The air exchange rates with different heating methods and temperature difference between the indoor and outdoor air were tested in the experiment room by using the tracer gas method. The test results show that the air exchange rate in heating room increases by 35%-40% compared with that without heating when the temperature difference between the room and the outside reaches 6-8 °C under the same conditions of the airtightness of doors and windows. As to the influence of the heating methods on the air exchange rate, it is slightly larger when the room is heated by supplying hot air than that in the room with radiant floor heating methods. The increase in the air infiltration caused by space heating should be considered when designing the residential heating system in this region. © 2019, Zhejiang University Press. All right reserved.
引用
收藏
页码:1415 / 1422
页数:7
相关论文
共 13 条
  • [1] Jokisalo J., Kurnitski J., Simulation of energy consumption in typical Finnish detached house, (2002)
  • [2] Wang J., Practice and experience sharing of housing airtightness testing, Construction Science and Technology, 18, pp. 74-77, (2014)
  • [3] Zhou X., Zhang Q.-Q., Zhang J.-S., Et al., Survey and heat demand analysis of winter residential indoor environment in Shanghai, Heating Ventilating and Air Conditioning, 43, 6, pp. 64-67, (2013)
  • [4] Wu X., Fang L., Olesen B.W., Et al., Comparison of indoor air distribution and thermal environment for different combinations of radiant heating systems with mechanical ventilation systems, Building Services Engineering Research and Technology, 39, 1, pp. 81-97, (2018)
  • [5] Marquez A.A., Lopez J.M.C., Hernandez F.F., Et al., A comparison of heating terminal units: fan-coil versus radiant floor, and the combination of both, Energy and Buildings, 138, 1, pp. 621-629, (2016)
  • [6] 2009 ASHRAE Handbook: Fundamentals, (2009)
  • [7] Li X.-F., Zhu Y.-X., Analysis of basic problems in tracer gas measurement technology (I): principles, methods and measuring equipment, National Academic Collection of HVAC, pp. 69-73, (1998)
  • [8] Laussmann D., Helm D., Air change measurements using tracer gases. chemistry, emission control, radioactive pollution and indoor air quality, pp. 365-404, (2011)
  • [9] Fujikawa M., Yoshino H., Takaki R., Et al., Experimental study of the multi-zonal airflow measurement method using human expiration, Journal of Environmental Engineering, 75, 652, pp. 499-508, (2010)
  • [10] Qi M.-W., Li X.-F., Huang H., Discussion on measuring ventilation rates of dorms through tracer gas method with human body as CO<sub>2</sub> release source, Building Science, 29, 6, pp. 52-57, (2013)