Study and economic evaluation on the process of calorific value adjustment in the LNG receiving terminal

被引:0
|
作者
Wang S. [1 ]
Huang K. [1 ,2 ]
Wang X. [3 ]
Liao N. [1 ]
Yan W. [3 ]
Pei Q. [3 ]
Xia B. [3 ]
机构
[1] School of Petroleum and Nature Gas Engineering of Southwest Petroleum University, Chengdu
[2] State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation, Southwest Petroleum University, Chengdu
[3] Measurement Research Center of Sinopec Natural Gas Company, Jinan
来源
Open Pet. Eng. J. | / 226-235期
关键词
Calorific value adjustment; Economic analysis; Energy measurement; Light hydrocarbons recovery; LNG receiving terminal; Nitrogen injection;
D O I
10.2174/1874834101609010226
中图分类号
学科分类号
摘要
In recent years, large quantities of LNG sources have occured in international trade, which have also presented themselves with vary compositions and contain more than 10 mol % light hydrocarbons components (such as ethane and propane).This paper takes a certain typical Chinese liquefied natural gas receiving terminal as an example. For the exchange and economic issues caused by high C2+ components in the feedstock of the above mentioned LNG terminal, an adjustion of the calorific value in products by adopting LH recovery, nitrogen gas injection and liquid nitrogen injection is advised. In order to evaluate profits in LNG receiving terminal, three kinds of processes have been simulated by using of the Aspen HYSYS to realize the consumption analysis. Further more, economic benefits of three schemes are analyzed based on energy measurements. It was shown that the after-tax net profit of the receiving terminal which adds liquid nitrogen to adjust calorific value is 6.17% higher than that which extracts C2+ components under the volume measurement system. Under the system of energy measurement, the after-tax net profit of three processes is respectively increased by 8.96%, 12.51% and 12.47% compared to the original measure modes. The results suggest that the proposed liquid nitrogen injection processes is the most effective one which injects at the exit of high-pressure efflux pump, and an economical way to adjust heat value, which has the highest net profit and the lowest consumption cost and capital cost in the current Chinese LNG industry chain and economic situation. © Wang et al.
引用
收藏
页码:226 / 235
页数:9
相关论文
共 50 条
  • [1] Multiobjective Design of Calorific Value Adjustment Process using Process Simulators
    Kim, Hosoo
    Kim, Ik Hyun
    Yoon, En Sup
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2010, 49 (06) : 2841 - 2848
  • [2] Design and economic analysis of natural gas hydrate regasification process combined with LNG receiving terminal
    Shin, Seolin
    Lee, Yongseok
    Song, Kiwook
    Na, Jonnggeol
    Park, Seongho
    Lee, Yeongbeom
    Lee, Chul-Jin
    Han, Chonghun
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2016, 112 : 64 - 77
  • [4] SIMULATION METHOD FOR EVALUATION OF LNG RECEIVING TERMINAL CAPACITY
    Dundovic, Cedomir
    Basch, Danko
    Dobrota, Dorde
    PROMET-TRAFFIC & TRANSPORTATION, 2009, 21 (02): : 103 - 112
  • [5] A Study on the Method for Measuring the live Calorific Value of LNG in storage tank using LNG Densitometer
    Ha, Youngcheol
    Lee, Seongmin
    KOREAN CHEMICAL ENGINEERING RESEARCH, 2011, 49 (01): : 35 - 40
  • [6] Optimization of boil-off gas recondensation process in LNG receiving terminal
    Key Laboratory of Heat Transfer Enhancement and Energy Conservation, South China University of Technology, Guangzhou 510640, Guangdong, China
    Huagong Xuebao, 2009, 11 (2876-2881):
  • [7] Seismic evaluation of existing structures supporting loading-arms in LNG Receiving Terminal
    Oshima, Masami
    Kase, Takashi
    American Society of Mechanical Engineers, Pressure Vessels and Piping Division (Publication) PVP, 2002, 445 (01): : 163 - 170
  • [8] A study on local residents' perception in communication process for LNG terminal risks
    Korkmaz, Serdar
    Park, Dal Jae
    INTERNATIONAL JOURNAL OF CRITICAL INFRASTRUCTURES, 2019, 15 (04) : 336 - 354
  • [9] Study of the large LNG receiving terminal fire risk and coping strategies based on scenario analysis
    Liu Xuanya
    Bi Yixing
    PROCEEDINGS OF THE FIRST SYMPOSIUM ON DISASTER RISK ANALYSIS AND MANAGEMENT IN CHINESE LITTORAL REGIONS, 2011, 18 : 251 - 256
  • [10] Thermodynamic and economic study of GUD power plant on use of fuel gases of low calorific value
    Klingemann, J
    Moricet, M
    CHEMIE INGENIEUR TECHNIK, 1996, 68 (10) : 1328 - 1331