Cross-talk reduction in a multiplexed synchroscan streak camera with simultaneous calibration

被引:0
|
作者
Hirmiz N. [1 ]
Tsikouras A. [2 ]
Osterlund E.J. [3 ]
Richards M. [2 ]
Andrews D.W. [3 ,4 ,5 ]
Fang Q. [1 ,2 ]
机构
[1] School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, L8S 4L7, ON
[2] Department of Engineering Physics, McMaster University, 1280 Main Street West, Hamilton, L8S 4L7, ON
[3] Department of Biochemistry, University of Toronto, 27 King's College Cir, Toronto, M5S 1A8, ON
[4] Department of Biochemistry and Biomedical Sciences, McMaster University, Main Street West, Hamilton, L8S 4L7, ON
[5] Biological Sciences, Sunnybrook Research Institute, University of Toronto, 2075 Bayview Ave., Toronto, M4N 3M4, ON
来源
Opt. Express | 2019年 / 16卷 / 22602-22614期
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
Crosstalk;
D O I
10.1364/OE.27.022602
中图分类号
学科分类号
摘要
The streak camera is a picosecond resolution photodetector with parallel input capability; however, the degree of multiplexing is limited by crosstalk and temporal uncertainty in the sweeping field. We introduced a fixed time delay between adjacent fibers to reduce crosstalk in the synchroscan mode. The fixed delay and a tunable electronic delay between the input pulse and the synchroscan unit allows robust separation modes between the streaks, while spatial and temporal nonlinearities can be calibrated in. The efficacy of the design is demonstrated through a 100-fold multiplexed confocal fluorescence lifetime imaging microscope in live cells. © 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:22602 / 22614
页数:12
相关论文
共 50 条
  • [1] Cross-talk reduction in a multiplexed synchroscan streak camera with simultaneous calibration
    Hirmiz, Nehad
    Tsikouras, Anthony
    Osterlund, Elizabeth J.
    Richards, Morgan
    Andrews, David W.
    Fang, Qiyin
    OPTICS EXPRESS, 2019, 27 (16): : 22602 - 22614
  • [2] CROSS-TALK EFFECTS IN MULTIPLEXED VOLUME HOLOGRAMS
    LEE, H
    OPTICS LETTERS, 1988, 13 (10) : 874 - 876
  • [3] CROSS-TALK IN WAVELENGTH-MULTIPLEXED HOLOGRAPHIC MEMORIES
    CURTIS, K
    GU, C
    PSALTIS, D
    OPTICS LETTERS, 1993, 18 (12) : 1001 - 1003
  • [4] Analysis of cross-talk noise in fractal multiplexed volume hologram
    Ouyang, C
    He, QS
    Song, XY
    Wang, JG
    Jin, GF
    ADVANCED OPTICAL STORAGE TECHNOLOGY, 2002, 4930 : 275 - 280
  • [5] Analysis of cross-talk noise in fractal multiplexed volume hologram
    He, Qing-Sheng
    Ouyang, Chuan
    Song, Xiu-Yu
    Wang, Jian-Gang
    Jin, Guo-Fan
    Guangxue Jishu/Optical Technique, 2002, 28 (05): : 386 - 388
  • [6] CROSS-TALK FOR ANGLE-MULTIPLEXED AND WAVELENGTH-MULTIPLEXED IMAGE PLANE HOLOGRAMS
    CURTIS, K
    PSALTIS, D
    OPTICS LETTERS, 1994, 19 (21) : 1774 - 1776
  • [7] Hierarchical beamformer and cross-talk reduction in electroneurography
    Calvetti, Daniela
    Wodlinger, Brian
    Durand, Dominique M.
    Somersalo, Erkki
    JOURNAL OF NEURAL ENGINEERING, 2011, 8 (05)
  • [8] Cross-talk reduction by smart delay firing
    Howkins, SD
    Willus, CA
    Nishimura, H
    IS&T'S NIP20: INTERNATIONAL CONFERENCE ON DIGITAL PRINTING TECHNOLOGIES, PROCEEDINGS, 2004, : 845 - 850
  • [9] REDUCTION OF CROSS-TALK IN AN ACOUSTOOPTIC SWITCH BY MEANS OF DILATION
    SMITH, DA
    DALESSANDRO, A
    BARAN, TE
    FRITZ, DJ
    HOBBS, RH
    OPTICS LETTERS, 1994, 19 (02) : 99 - 101
  • [10] TEMPORAL MODULATION FOR COMPUTATIONAL VIDEO CROSS-TALK REDUCTION
    Park, Dookun
    Samadani, Ramin
    Tan, Kar-Han
    Gelb, Dan
    2012 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP 2012), 2012, : 2101 - 2104